AN3964 Application note How to design a simple temperature measurement application
... This application note describes a method of implementing a simple application for temperature measurement using the STM32L-DISCOVERY. The solution described in this document uses the integrated temperature sensor of the STM32L1 microcontroller. The factory or user calibration method is described to ...
... This application note describes a method of implementing a simple application for temperature measurement using the STM32L-DISCOVERY. The solution described in this document uses the integrated temperature sensor of the STM32L1 microcontroller. The factory or user calibration method is described to ...
a Low Voltage, 10-Bit Digital Temperature Sensor in 8-Lead MSOP AD7314
... Figure 3 also shows the interface diagram for a serial write to the AD7314. The write operation takes place at the same time as the read operation. Data is clocked into the control register on the falling edge of SCLK. Only the third bit in the data stream provides a user-controlled function. This t ...
... Figure 3 also shows the interface diagram for a serial write to the AD7314. The write operation takes place at the same time as the read operation. Data is clocked into the control register on the falling edge of SCLK. Only the third bit in the data stream provides a user-controlled function. This t ...
chapter21
... Resistivity is a property of a substance Resistance is a property of an object The resistance of a material depends on its geometry and its resistivity An ideal (perfect) conductor would have zero resistivity An ideal insulator would have infinite resistivity ...
... Resistivity is a property of a substance Resistance is a property of an object The resistance of a material depends on its geometry and its resistivity An ideal (perfect) conductor would have zero resistivity An ideal insulator would have infinite resistivity ...
HumiSeal® 1B73
... pressure will depend on the specific type of spray equipment used. The spraying should be done under an exhaust hood so that the vapor and mist are carried away from the operator. The recommended ratio of HumiSeal Type 1B73 to HumiSeal Thinner 73 is 1 to 1 by volume, as a starting point. The quantit ...
... pressure will depend on the specific type of spray equipment used. The spraying should be done under an exhaust hood so that the vapor and mist are carried away from the operator. The recommended ratio of HumiSeal Type 1B73 to HumiSeal Thinner 73 is 1 to 1 by volume, as a starting point. The quantit ...
TEMPERATURE AND FREQUENCY DEPENDENCE OF PRECISION Luka Ferković
... when βi < βCu, wire can became loosely. Therefore, in the working conditions, where the larger temperature changes are expected, the temperature coefficient βi of body material should be as close as possible to βCu. ...
... when βi < βCu, wire can became loosely. Therefore, in the working conditions, where the larger temperature changes are expected, the temperature coefficient βi of body material should be as close as possible to βCu. ...
SESSION 10
... But some of the devices do not obey that rule (like a pn junction diode), whereas other do (like a resistor). We can state then that A conducting device obeys Ohm’s law when its resistance is independent of the magnitude and polarity of the applied potential difference. Power in electric circuits If ...
... But some of the devices do not obey that rule (like a pn junction diode), whereas other do (like a resistor). We can state then that A conducting device obeys Ohm’s law when its resistance is independent of the magnitude and polarity of the applied potential difference. Power in electric circuits If ...
The Petite Fridge - Health Care Logistics
... were placed in three locations within each of the refrigerators intermingled with the simulated medications. Room temperature and humidity were controlled. The collective results of the testing are as follows: At room temperatures between 69o and 73o F (21º and 23ºC) and a humidity range averaging 4 ...
... were placed in three locations within each of the refrigerators intermingled with the simulated medications. Room temperature and humidity were controlled. The collective results of the testing are as follows: At room temperatures between 69o and 73o F (21º and 23ºC) and a humidity range averaging 4 ...
Lumped element model
The lumped element model (also called lumped parameter model, or lumped component model) simplifies the description of the behaviour of spatially distributed physical systems into a topology consisting of discrete entities that approximate the behaviour of the distributed system under certain assumptions. It is useful in electrical systems (including electronics), mechanical multibody systems, heat transfer, acoustics, etc.Mathematically speaking, the simplification reduces the state space of the system to a finite dimension, and the partial differential equations (PDEs) of the continuous (infinite-dimensional) time and space model of the physical system into ordinary differential equations (ODEs) with a finite number of parameters.