• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Sign in Sign up
Upload
HRP - WordPress.com
HRP - WordPress.com

... an oxidoreductase. HRP has proved to be a robust enzyme that maintains activity over an extended time, making it quite suitable for study in an undergraduate teaching lab. The overall focus of this project is to isolate HRP using multiple protein purification techniques, such as gel filtration, ion ...
Improved detection and identification of low
Improved detection and identification of low

... over 20 h. IPG strips can also be run on IPGphor™ electrophoresis unit using paper bridges on Cup Loading Strip Holder, which achieves equally high spot resolution. All chemicals and reagents used for the second dimension of 2-D electrophoresis are described in reference 6. Initial equilibration of ...
pharmacognosy lec 6
pharmacognosy lec 6

... Analyte, stationary phase, and mobile phase. The observer could represent the detector used in some forms of analytical chromatography. A key point is that the detector need not be capable of discriminating between the analytes, since they have become separated before passing the detector. Chromatog ...
ASMS 2004 de Novo
ASMS 2004 de Novo

... Ionization of peptides and protein digests via MALDI preferentially yields singly charged analyte ions, and the fragmentations of these precursor ions often generate higher background in MS/MS spectra and undergo preferential cleavages. Selective fragmentation reactions limit the amount of de Novo p ...
Proteome
Proteome

... final analysis on basis of label. – Avoid some proportion of technical variance – Best to worst (for avoiding technical variance): • Labelling in vivo • Labelling protein mixture • Labelling peptide digestion mixture ...
ELECTROMETRIC TITRATION OF CHLORIDE IN SMALL VOLUMES
ELECTROMETRIC TITRATION OF CHLORIDE IN SMALL VOLUMES

... two factors: (a) the deterioration in the sharpness of the end-point as the dilution is increased, and (b) the increase in volumetric error as the volumes of sample and titrant are reduced. Schwarz & Schlosser pointed out that the sharpness of the end-point depends upon the solubility product of sil ...
MIAPE_Quant_v1.0_SILAC_MLHS
MIAPE_Quant_v1.0_SILAC_MLHS

... 5.1 Quantification values at peptide and/or feature level: Actual quantification values achieved for each peptide and/or, in case of feature-based quantification, for the corresponding features (mapped back from each peptide), together with their estimated confidence. ...
Document
Document

... Direct detection of resistance genes (MecA, VRE, CTX-M, KPC, NDM) ...
Introduction to Spectroscopy mod4 - Rose
Introduction to Spectroscopy mod4 - Rose

... functioning of a PMT requires a constant voltage across the PMT; maintaining a constant voltage in the face of a high signal requires a well-designed instrument. PMTs are wavelength dependent, with the degree of dependence being related to the metal used in the thin film; most PMTs exhibit the great ...
Hydrophobic Interaction Chromatography (HIC
Hydrophobic Interaction Chromatography (HIC

... CityLab’s SummerLab 4 IV. Rinse the Column with Wash Buffer The wash buffer has a salt concentration that is lower than the binding buffer. It will wash away the weak hydrophobic proteins. GFP is a strong hydrophobic protein. Notebook Entry: Predict whether GFP will be washed off the beads by the w ...
Troubleshooting SDS-PAGE-0410
Troubleshooting SDS-PAGE-0410

... Problem: Bands are skewed or disorted The salt concentration is too Dialyze the sample, precipitate the protein with trichloroacetic acid high (TCA) or use a desalting column. The polymerization around Increase the amount of ammonium persulfate and TEMED. the sample wells is poor Excessive pressure ...
Evaluating Structural Differences in Cortical Bone Tissue
Evaluating Structural Differences in Cortical Bone Tissue

... Although the best results in bone grafting have been achieved with autogeneuos bone tissue, allografts and xenografts have been widely used either in mineralized, demineralized, or calcined forms. Demineralized bone has been proven to stimulate new bone formation by exposing, proteins and growth fac ...
Nickel Affinity Chromatography Protocol/Guide
Nickel Affinity Chromatography Protocol/Guide

... o Increasing the pH of the equilibration buffer from 7 to 8 will increase the binding of your protein to the NTA beads, but will also increase non-specific binding of other proteins. Start using a pH 7.0 buffer unless you are having a difficult time getting the protein to bind to the beads. o Adding ...
Determining Lactose Content In Milk by Polarimetry
Determining Lactose Content In Milk by Polarimetry

... polarimeter tube. It is affected by temperature (20°C reference temperature) and wavelength (usually the sodium D line, 589 nm, is used), and can be measured using the following formula: ...
2-D Quant Kit - GE Healthcare Life Sciences
2-D Quant Kit - GE Healthcare Life Sciences

... The 2-D Quant Kit circumvents these limitations and can be used to accurately quantify protein samples prepared for 2-D electrophoresis as well as any sample that contains substances that otherwise interfere with protein quantification. The procedure uses a combination of a unique precipitant and co ...
18_2014_1558_MOESM8_ESM
18_2014_1558_MOESM8_ESM

... represents protein relative abundance. Thresholds for decreased and increased abundance were set at <0.83 and >1.2, respectively. The P-value was calculated using Stouffer’s z-test, which enables P-values from several protein ratios belonging to the same analysis group to be combined, generating a s ...
Efficiency assay of detergent removal columns on - G
Efficiency assay of detergent removal columns on - G

... and suppress peptide ionization when analyzed by mass spectrometry. New (GB‐S10) detergent removal columns from G‐Biosciences were tested for their efficiency to remove anionic, nonionic or zwitterionic detergents (e.g. SDS, TritonX100 or CHAPS) from protein and tryptic peptide samples with minimal  ...
Sample Preparation 2D-GE
Sample Preparation 2D-GE

... gel pieces to disintegrate, making the in-gel digestion procedure more difficult and reducing recovery of digested protein. 7. Label tubes clearly and place tape over writing 8. Tubes can be shipped via FedEx next day air. Reagents to avoid There are many common biochemical reagents that are not com ...
Capillary Electrophoresis of Proteins
Capillary Electrophoresis of Proteins

... – 24 is maximum number of injections due to polymer build up on interface block – Buffer vials incremented every 8 runs • Necessary due to polymer build up on the vial cap ...
DiaEasy - BioVision
DiaEasy - BioVision

... Biovision’s DiaEasy™ dialyzer (1 kDa MWCO) can be used primarily for dialysis or buffer exchanges of sample volumes upto 15 ml. They can also be used for several other purposes as shown below. The DiaEasy™ tube’s membrane is ultra-clean, sulfur and heavy metal free and EDTA treated which makes it su ...
PolyWAX LP ERLIC instructions
PolyWAX LP ERLIC instructions

... B in no less than 20’ if the sample is likely to contain peptides with at least 3 phosphate groups. For analysis of tryptic digests containing large numbers of phosphate groups, running a longer gradient and collecting more fractions will result in significantly more phosphopeptides being identified ...
Electrophoresis HCC 2013 BMS2 intro
Electrophoresis HCC 2013 BMS2 intro

... • The smaller the polypeptides size, the higher acrylamide concentration needed to properly separate. * Otherwise, the small proteins would just race through the gel matrix with no quantitative results for classifying polypeptides. * The best concentration for particular size ranges has thankfully b ...
Limited Proteolysis
Limited Proteolysis

... 0.5 mL immobilized trypsin, and (c) fully-digested for 24hours with 0.5 mL immobilized trypsin MDH. A spectrum of the undigested protein is seen in Figure 2a and shows only the standards used (myoglobin ~17 kDa, and BSA ~ 66 kDa) and native MDH. The small peak at 50 kDa is most likely due to impurit ...
2-3 Solving Systems with Matrices
2-3 Solving Systems with Matrices

... A. If a matrix has an inverse, it is called invertible (or nonsingular); otherwise, it is called singular. Remember, only a square matrix can have an inverse. But not all square matrices have inverses. If, however, a matrix does have an inverse, that inverse is unique. 1. To determine if a matrix ha ...
Document
Document

... for reproducing focusing conditions. This needs to be ...
1 2 >

Sample preparation in mass spectrometry

The sample preparation for mass spectrometry is used for the optimisation of a sample for the analysis in a mass spectrometer (MS).These have depending on their ion source different requirements for volume, concentration, and composition of the analyte solution. Furthermore, in protein mass spectrometry usually the protein of interest is cleaved into peptides before analysis, either by in-gel digestion or by proteolysis in solution.
  • studyres.com © 2023
  • DMCA
  • Privacy
  • Terms
  • Report