• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DL Quench Detection System
DL Quench Detection System

... voltages over time or temperature changes. This high impedance is important and ensures that only a small amount of current is taken from the solenoid during operation. The Amplifier is protected from any voltage spikes by two opposing diodes connected across its input pins, this will minimise the i ...
Ignitron Driver Manual - Wide Bandwidth High Voltage Probes
Ignitron Driver Manual - Wide Bandwidth High Voltage Probes

... An accessory consisting of an 8 kV diode, and 3 kV spark gap is provided on all boards. This accessory prevents positive voltages of greater than 3 kV from being applied to the trigger unit. Negative voltages are protected by diodes in the unit itself. Such voltages are sometimes applied to the igni ...
Troubleshooting Techniques
Troubleshooting Techniques

... possibility is that the IC is bad. Verify that the reference voltage is correct. If the reference voltage is okay, and if it is possible to force the comparator into the alternate state, then the comparator is okay, and the likely problem is with the input signal. ...
Simple Method for Predicting a Cable Shielding Factor, Based on
Simple Method for Predicting a Cable Shielding Factor, Based on

Three-Phase Brushless Motor Driver
Three-Phase Brushless Motor Driver

Ch21_Faraday_ANS
Ch21_Faraday_ANS

... CCW current will create an induced B out of the page. This current is an example of an "eddy current". Question 2: B) left. Method I (the easy way ): The magnetic forces on eddy currents are always in the direction which opposes the motion. (Otherwise you could make a perpetual motion machine). Meth ...
+ - A +
+ - A +

... If the voltage of the voltage source VS = 0, then the voltage VAB = 0. The potentials of the point A and point B are equal. Compare to the wire connecting points A and B: No matter what current is flowing through the wire, VAB = 0. The voltage source with ZERO voltage is equivalent to a wire (shortc ...
If you move a bar magnet toward a loop of wire, it causes an electric
If you move a bar magnet toward a loop of wire, it causes an electric

... What does this mean? If you move a bar magnet toward a loop of wire, it increases the flux through the loop, which induces a voltage around the loop, which causes an electric current to flow in the wire! It means you no longer need to comb your cat on a dry day to create electric current, and you no ...
Chapter 2 Interconnect Parasitic Extraction
Chapter 2 Interconnect Parasitic Extraction

... – 10W chip draws 4A at 2.5V – Peak current may be 10-20A ...
IMT17
IMT17

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
A/C Generator Systems
A/C Generator Systems

TSP-WG6-20MA-15V-04 - Axiomatic Technologies Corporation
TSP-WG6-20MA-15V-04 - Axiomatic Technologies Corporation

... system input and power supply. It also has a LINE SIGNAL and POWER side which is connected to the transmission wire. The EARTH connection of the modules must be terminated to earth by low impedance heavy gauge wire. ...
(3D IC) Floorplan and Power/Ground Network Co
(3D IC) Floorplan and Power/Ground Network Co

... • A 3D Floorplan and P/G Co-synthesis tool was developed to create the 3D floorplan and the 3D P/G network simultaneously. • By considering the IR drop while floorplanning, exploring the 3D P/G design space, and evaluating 3D IC’s effect on 3D P/G networks, a more efficiently designed P/G network ca ...
Torque On A Current Loop In A Uniform Magnetic Field
Torque On A Current Loop In A Uniform Magnetic Field

... presence of a uniform magnetic field in the plane of the loop. ...
2x5, LC Duplex Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet
2x5, LC Duplex Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

1.5A switch step down switching regulator
1.5A switch step down switching regulator

Technical Teaching Equipment
Technical Teaching Equipment

... Three sounders connections. Lamp 24 VDC. Contacts: One Normally Open Contact (NO). Fuse: 5A. Ground terminal. • EMT7. Asynchronous Three-Phase Motor of Squirrel Cage. Nominal power: 370 W. Nominal voltage: 3x 230/400 VAC Δ/Y. Frequency: 50/60 Hz. Number of poles: 2. RPM: 2730 r.p.m. Nominal current: ...
The ME118 SN754410 Dual 1A H-Bridge Module
The ME118 SN754410 Dual 1A H-Bridge Module

... J3, pin 2 : Since the SN754410 is capable of switching two H-Bridge channels at a maximum of 1A each, care must be taken in the methods employed returning this substantial current to ground. For this reason, a separate high-current ground connection is available at J3, pin 2. A separate connection s ...
Buck Boost Converter Seminar.pdf
Buck Boost Converter Seminar.pdf

UML4N
UML4N

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of which would directly endange ...
OIL PRESSURE GAUGE and SENDER Model # GIOP, GIOP80
OIL PRESSURE GAUGE and SENDER Model # GIOP, GIOP80

... STEP ONE(this usually solves the problem) - Before you do anything else, check for defective wiring or grounds, as this is the most common cause of failures. Inspect all wiring an terminals. Also, look for corroded or missing engine ground strap connections. ...
clipper circuits
clipper circuits

... open switch. Consequently the entire input voltage appears across the diode or across the load resistance RL if R is much smaller than RL ...
Data Sheet-AR-2330D
Data Sheet-AR-2330D

... 220V or 230V via an internal jumper. The AR-2330D can handle loads totaling up to 30 amps as long as the input voltage is above the selected output voltage. For voltages below that level, its capacity must be derated at approximately .15 amperes per volt. The AR-2330D has been designed specifically ...
Truepath Assembly Instructions
Truepath Assembly Instructions

HMC430LP4 数据资料DataSheet下载
HMC430LP4 数据资料DataSheet下载

... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
< 1 ... 205 206 207 208 209 210 211 212 213 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report