• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
16890_chapter-06-elect-measurements-meters
16890_chapter-06-elect-measurements-meters

... • Caution: – Always turn off power before connecting an ammeter to a circuit – An analog ammeter must never be connected in parallel – Never connect an ammeter directly to a voltage source ...
Analog signal chain design considerations
Analog signal chain design considerations

RF5622 3.0V TO 3.6V, 2.4GHz TO 2.5GHz LINEAR POWER AMPLIFIER Features
RF5622 3.0V TO 3.6V, 2.4GHz TO 2.5GHz LINEAR POWER AMPLIFIER Features

... Description RF input. Input is matched to 50 and DC block is provided internally. Bias current control voltage for the first and second amplifier stage. Power detector which provides an output voltage proportional to the RF output power level. May need external decoupling capacitor for load sensiti ...
AN-5044 Analog Switches with 2V Undershoot Protection −
AN-5044 Analog Switches with 2V Undershoot Protection −

A novel square-root domain realization of first
A novel square-root domain realization of first

... power consumption and the total harmonic distortion were measured as 2.54 mW and 1.41%, respectively. The dependence of the output harmonic distortion of presented filter on input signal amplitude is illustrated in Figure 6. As shown in this figure, THD increases with input signal. As such, input sign ...
LM337 - 1.5 A, Adjustable Output Negative Voltage Regulator
LM337 - 1.5 A, Adjustable Output Negative Voltage Regulator

TO: ALL SALES FORCE FROM: Blue Streak Tech
TO: ALL SALES FORCE FROM: Blue Streak Tech

... the conformal-coat that is applied to the ECM circuit board. The conformal-coat is applied to the circuit board to help protect the ECM from corrosion and the elements. However, after some time, the conformal-coat may shift, swell, or spread, causing the movement of certain electronic components on ...
Chapter3 : Oscilloscope Measurement Techniques
Chapter3 : Oscilloscope Measurement Techniques

2938633 Datasheet
2938633 Datasheet

... Devices of the same type can be connected in parallel to increase both redundancy and power. The default setting does not have to be adjusted. A maximum of five devices can be connected in parallel. If the output voltage is adjusted, an even current distribution can be ensured by precisely setting a ...
Evaluates: MAX105/MAX107 MAX105 Evaluation Kit General Description Features
Evaluates: MAX105/MAX107 MAX105 Evaluation Kit General Description Features

... ADC. Ferrite beads are used to filter out high-frequency noise at the analog power supply. At 100MHz, the ferrite beads have an impedance of 600Ω. ...
A Single-Phase Energy Meter with Capacitive Power Supply
A Single-Phase Energy Meter with Capacitive Power Supply

FAN8303 2A 23V Non-Synchronous Step-Down DC/DC Regulator FAN8303 — 2A 23V Non-Synchr Features
FAN8303 2A 23V Non-Synchronous Step-Down DC/DC Regulator FAN8303 — 2A 23V Non-Synchr Features

... to about 45kHz when the output is shorted to ground. This frequency fold-back allows the inductor current more time to decay to prevent potential run-away condition. The oscillator frequency switches to 370kHz as VOUT rises gradually from 0V back to regulated level. ...
TECH TIPS
TECH TIPS

... Alternators that are being installed on inboard gasoline engines must be certified to meet Coast Guard requirements for ignition protection. In order for the alternator to be certified, it must pass the testing procedure, Marine SAE J1171, laid-out by the Society of Automotive Engineers (SAE). Brush ...
All amplifiers are analogue, but some amplifiers are more
All amplifiers are analogue, but some amplifiers are more

... does not. Figure 5 shows the output current of the power stage. The current waveform is in fact a pair of sinusoids with a high-frequency triangle superimposed on it. It stands to reason that the myth of the “digital amplifier” would have never taken off if it had been as common to show current wave ...
Aalborg Universitet
Aalborg Universitet

Mojotone Tweed Champ Style Amp Kit
Mojotone Tweed Champ Style Amp Kit

... Turn amp on without tubes installed first, checking transformers and components for shorting, excessive heat, arcing, smoking, etc. ...
High-Resolution Electrometer with Micromechanical Variable
High-Resolution Electrometer with Micromechanical Variable

... bandwidth of 1 Hz and a full-scale voltage of 1V. The series represented by triangles used a 3.1 Hz bandwidth and 50 mV fullscale. The maximum relative error of the entire series with respect to a linear fit is less than 15%. Also plotted on Fig. 7 is the noise floor of the lower-range measurement, ...
An Oscillating Active CMOS Pixel for Subretinal Stimulation
An Oscillating Active CMOS Pixel for Subretinal Stimulation

AN-5023 LVDS Compatibility with RS422 and RS485 Interface Standards AN-
AN-5023 LVDS Compatibility with RS422 and RS485 Interface Standards AN-

... © 2002 Fairchild Semiconductor Corporation ...
Workshop Attendee Notes
Workshop Attendee Notes

1C.6.1—Voltage Disturbances
1C.6.1—Voltage Disturbances

earth grounding resistance
earth grounding resistance

final_paper
final_paper

PS22A76
PS22A76

... 1 :If control GND and power GND are patterned by common wiring, it may cause malfunction by fluctuation of power GND level. It is recommended to connect control GND and power GND at only a N1 point at which NU, NV, NW are connected to power GND line. 2 :It is recommended to insert a Zener diode D1 ( ...
2SC4793
2SC4793

... Tc = 25°C Curves must be derated linearly with increase in temperature. VCEO max ...
< 1 ... 169 170 171 172 173 174 175 176 177 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.