Ü ÿ Ÿ - Tascam
... This switch should be used in conjunction with the “reference level” settings on various pieces of TASCAM equipment. When an analog signal is at its nominal level (i.e. the meter reads “0 dB”), the signal level on digital equipment must not read 0 dB—this would mean that any signals above 0 dB (anal ...
... This switch should be used in conjunction with the “reference level” settings on various pieces of TASCAM equipment. When an analog signal is at its nominal level (i.e. the meter reads “0 dB”), the signal level on digital equipment must not read 0 dB—this would mean that any signals above 0 dB (anal ...
technical note - Digi-Key
... output cable and handle assembly through the cartridge. If the resistance of the output circuit exceeds a preset reference level, the system is turned off. This is fail-safe protection against any ground loss. On the OK International MFR Series and the Metcal MX-5000 Series soldering systems, a grou ...
... output cable and handle assembly through the cartridge. If the resistance of the output circuit exceeds a preset reference level, the system is turned off. This is fail-safe protection against any ground loss. On the OK International MFR Series and the Metcal MX-5000 Series soldering systems, a grou ...
Circuit Loading and the OP AMP
... example, if the meter has the specification 10,000 Ω /V, then the meter input resistance on the 10 V range is 100 kΩ . If the Ω /V specification is present on the AMM you used for this exercise, calculate the meter input resistance on each VDC range. For each voltage range compute the percent error ...
... example, if the meter has the specification 10,000 Ω /V, then the meter input resistance on the 10 V range is 100 kΩ . If the Ω /V specification is present on the AMM you used for this exercise, calculate the meter input resistance on each VDC range. For each voltage range compute the percent error ...
NSEQ-2 Twin Topology Stereo Parametric Equalizer
... not likely to be walked on or pinched by having objects placed on it. Pay particular attention to plugs, receptacles, and the point where the AC power cord exits the NSEQ-2. 4. GROUNDING For your safety, it is extremely important that the grounding pin of the 3-wire power cable (included with unit) ...
... not likely to be walked on or pinched by having objects placed on it. Pay particular attention to plugs, receptacles, and the point where the AC power cord exits the NSEQ-2. 4. GROUNDING For your safety, it is extremely important that the grounding pin of the 3-wire power cable (included with unit) ...
BDTIC C C M - P F C
... The IC is designed not to support any output power that corresponds to a voltage lower than -0.75V at the ISENSE pin. A further increase in the inductor current, which results in a lower ISENSE voltage, will activate the Soft Over Current Control (SOC). This is a soft control as it does not directly ...
... The IC is designed not to support any output power that corresponds to a voltage lower than -0.75V at the ISENSE pin. A further increase in the inductor current, which results in a lower ISENSE voltage, will activate the Soft Over Current Control (SOC). This is a soft control as it does not directly ...
MIL EMI and Transient Solutions
... lead connections. This represents a potentially large loop cross-sectional area that, if not effectively controlled, can generate magnetic fields. Common mode noise is a function of the dv/dt across the main switch in the converter and the effective input to output capacitance of the converter. Diff ...
... lead connections. This represents a potentially large loop cross-sectional area that, if not effectively controlled, can generate magnetic fields. Common mode noise is a function of the dv/dt across the main switch in the converter and the effective input to output capacitance of the converter. Diff ...
Differential Voltage Probe
... mentioned before, the amplifier allows you to measure positive and negative voltages on any of our interfaces. Since many lab interfaces can read voltages only in the range of 0 to 5 volts, the amplifier offsets and amplifies the incoming signal so that the output is always in the range of 0 to 5 vo ...
... mentioned before, the amplifier allows you to measure positive and negative voltages on any of our interfaces. Since many lab interfaces can read voltages only in the range of 0 to 5 volts, the amplifier offsets and amplifies the incoming signal so that the output is always in the range of 0 to 5 vo ...
AT-7000 Advanced Wire Tracer
... Get accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification. The Receiver’s patented Smart Sensor,™ with its innovative new antenna design and advanced signal processor, clearly displays the location and orientation of energized wires in w ...
... Get accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification. The Receiver’s patented Smart Sensor,™ with its innovative new antenna design and advanced signal processor, clearly displays the location and orientation of energized wires in w ...
nti-power_quality_at.. - IDEAL INDUSTRIES, INC.
... General tester can not identify high resistance or series faults • Nor can they identify a neutral to ground bond – Glowing contacts in copper or aluminum wiring – High resistance in Back-wired devices like receptacle – Loose or corroded connections – Bad splices – Hot plugs, or high resistance cont ...
... General tester can not identify high resistance or series faults • Nor can they identify a neutral to ground bond – Glowing contacts in copper or aluminum wiring – High resistance in Back-wired devices like receptacle – Loose or corroded connections – Bad splices – Hot plugs, or high resistance cont ...
Evaluation Board User Guide
... implied, or statutory including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. No license is granted by implication or otherwise under any patents or other intellectual property by application or use of evaluation boards. Information furnished by An ...
... implied, or statutory including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. No license is granted by implication or otherwise under any patents or other intellectual property by application or use of evaluation boards. Information furnished by An ...
F5019 - Fuji Electric America
... • Electrical home appliances • Personal equipment • Industrial robots etc. 5. If you need to use a product in this Catalog for equipment requiring higher reliability than normal, such as for the equipment listed below, it is imperative to contact Fuji Electric Systems Co., Ltd. to obtain prior appro ...
... • Electrical home appliances • Personal equipment • Industrial robots etc. 5. If you need to use a product in this Catalog for equipment requiring higher reliability than normal, such as for the equipment listed below, it is imperative to contact Fuji Electric Systems Co., Ltd. to obtain prior appro ...
quint-ps-100-240ac/24dc/5
... The two DC OK outputs are for preventive function monitoring of the power supply unit. A floating signal contact 4 and an active DC OK signal 3 are available. In addition, the DC OK LED 6 can be used to evaluate the function of the power supply directly at the installation location (see "Status Indi ...
... The two DC OK outputs are for preventive function monitoring of the power supply unit. A floating signal contact 4 and an active DC OK signal 3 are available. In addition, the DC OK LED 6 can be used to evaluate the function of the power supply directly at the installation location (see "Status Indi ...
SMA - SMA 2
... These devices and their accessories may only be operated in compliance with the operating instructions (intended use)! These devices and their accessories may only be commissioned by trained and qualified personnel. These devices may only be operated with the intended operating voltages and paramete ...
... These devices and their accessories may only be operated in compliance with the operating instructions (intended use)! These devices and their accessories may only be commissioned by trained and qualified personnel. These devices may only be operated with the intended operating voltages and paramete ...
6517B Electrometer/High Resistance Meter
... a sample, measure the current that flows through the sample, then calculate the resistance using Ohm’s Law (R=V/I.) While high resistance materials and devices produce very small currents that are difficult to measure accurately, Keithley electrometers and picoammeters are used successfully for such ...
... a sample, measure the current that flows through the sample, then calculate the resistance using Ohm’s Law (R=V/I.) While high resistance materials and devices produce very small currents that are difficult to measure accurately, Keithley electrometers and picoammeters are used successfully for such ...
Ground loop problems and how to get rid of them
... (60Hz in the US, 50Hz in Europe) through the sound system. A ground loop in the power or video signal occurs when some components in the same system are receiving its power from a different ground than other components, or the ground potential between two pieces of equipment is not ...
... (60Hz in the US, 50Hz in Europe) through the sound system. A ground loop in the power or video signal occurs when some components in the same system are receiving its power from a different ground than other components, or the ground potential between two pieces of equipment is not ...
The QUICKEST way to wire.
... • OnePass wiring is rated at 20A with 90ºC 12 AWG conductors. The OnePass OC2 cable also is available in a 10AWG, 20A option to reduce voltage drop on longer runs. • All components are keyed to prevent different voltages from connecting, and color-coded cable heads allow for easy identification. ...
... • OnePass wiring is rated at 20A with 90ºC 12 AWG conductors. The OnePass OC2 cable also is available in a 10AWG, 20A option to reduce voltage drop on longer runs. • All components are keyed to prevent different voltages from connecting, and color-coded cable heads allow for easy identification. ...
AN-107 - IXYS Integrated Circuits Division
... as the Electrocardiogram (ECG) presents some special problems. Cardiac signals for adults are approximately 1mV in magnitude while for a fetus can be as low as 50µV. Since the heart signals are low in amplitude, noise such as residual electrode voltages and 50/60Hz power line pickup can easily mask ...
... as the Electrocardiogram (ECG) presents some special problems. Cardiac signals for adults are approximately 1mV in magnitude while for a fetus can be as low as 50µV. Since the heart signals are low in amplitude, noise such as residual electrode voltages and 50/60Hz power line pickup can easily mask ...
65-0084 7800 Series Q7800A,B 22
... withstand high voltages up to 25,000 Vrms in a salt bath for one minute without breakdown. It is rated at 200°F (93°C) for continuous duty, and up to 350°F (177°C) for intermittent use.) Recommended grounding practices: a. Each 7800 SERIES Relay Module or S7830A will have an earth ground terminal G ...
... withstand high voltages up to 25,000 Vrms in a salt bath for one minute without breakdown. It is rated at 200°F (93°C) for continuous duty, and up to 350°F (177°C) for intermittent use.) Recommended grounding practices: a. Each 7800 SERIES Relay Module or S7830A will have an earth ground terminal G ...
product manual for st6917 (me003 - m9417 - 1 - c) - Metrix
... Minimum supply voltage = 260 (1V/50 ohms) + 10V = 15.2 VDC The maximum loop power supply voltage that may be applied is 30 VDC. The maximum loop resistance (RL) is calculated by the equation: RL = 50 (VS - 10) ohms Example: RL = 50 (24 - 10) = 700 ohms for 24 VDC loop supply. CONNECTION TO PLC OR OT ...
... Minimum supply voltage = 260 (1V/50 ohms) + 10V = 15.2 VDC The maximum loop power supply voltage that may be applied is 30 VDC. The maximum loop resistance (RL) is calculated by the equation: RL = 50 (VS - 10) ohms Example: RL = 50 (24 - 10) = 700 ohms for 24 VDC loop supply. CONNECTION TO PLC OR OT ...