Download The QUICKEST way to wire.

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Power inverter wikipedia , lookup

Rectifier wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Islanding wikipedia , lookup

Fault tolerance wikipedia , lookup

Opto-isolator wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Skin effect wikipedia , lookup

Electrical substation wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Buck converter wikipedia , lookup

Loading coil wikipedia , lookup

Rectiverter wikipedia , lookup

Power over Ethernet wikipedia , lookup

Transmission tower wikipedia , lookup

Ground (electricity) wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Earthing system wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Home wiring wikipedia , lookup

National Electrical Code wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Electrical wiring wikipedia , lookup

Transcript
T h e
# 1
S e l l i n g
M o d u l a r
W i r i n g
S o l u t i o n
S i n c e
1 9 7 7
The QUICKEST
way to wire.
For recessed-ceiling,
open-ceiling and
power applications.
the RELOC Advantage
®
• Innovative, patented products
• Fast estimating and simple ordering
• Lowest total job cost
• Easy fixture relocation
• Easy project management
• Safety and reliability
RELOC® Wiring Solutions
In
today’s
fast-paced
construction
market, staying on schedule and under
budget is tougher than ever. Every job
demands wiring solutions that reduce
installation time and adapt to changes,
whether they occur during construction
or after a building is occupied. With rising
labor costs and the shortage of qualified
electricians, traditional wiring methods no
longer measure up.
RELOC Wiring Solutions from Acuity Brands
Lighting has been the leader in modular
wiring since 1977. Reloc offers three
unique wiring systems that are fast, easy
and effective: Quick-Flex® wiring for
recessed ceiling lighting installations,
OnePass® system for open-ceiling lighting
installations and System 820 for specialty
lighting and power applications.
Reduce, Reuse, Recycle. . .RELOC®
REDUC
E
USE
RE
Y
REC CLE
RELOC products are a greener solution than traditional wiring. RELOC products minimize installation
time and construction waste while maximizing productivity, reusability and the use of recycled materials.
Please see www.acuitybrandslighting.com/sustainability for more information.
Lowest Total Job Cost
Easy Fixture Relocation
RELOC components snap together in a frac-
Complete
tion of the time it takes to wire a fixture with
and inexpensively by reusing RELOC
conventional wiring methods — and require
components. Simply unplug the original
less labor and fewer materials. Installation
system,
time is reduced by up to 66 percent, result-
reconnect the system. Quick changes
ing in significantly reduced total job cost.
minimize facility down-time.
Easy Project Management
Safety and Reliability
RELOC wiring enhances the ability to
All RELOC components are 100-percent
plan and manage a tight schedule. Since
electrically tested. Safety features such
RELOC wiring is installed with fixtures in
as dead-fronted contacts are designed to
the finish phase, labor, material costs and
comply with UL183 and CSA 22.2 203.1
trade conflicts are reduced during the
(standard for manufactured wiring sys-
critical rough-in stage.
tems) and 2008 NEC 410.130 (G) and
wiring
relocate
changes
the
quickly
fixtures
and
Quick-Flex®
OnePass®
CEC 30-308 (ballast disconnective means)
Fast Estimating and
Simple Ordering
while following standard safety practices.
RELOC estimating tools provide fast project
System 820
estimates and simple ordering, eliminating the need for time-consuming factory
drawings.
RELOC Wiring Offers
Lowest Total Job Cost vs.
Traditional Wiring Methods
Manufactured wiring systems
are described in NEC 604 and
Canadian CEC 12-2500.
All products are UL Listed,
NYC Approved and C-UL Listed
or CSA Certified.
New York City
Approved
Calendar Numbers
47802, 48072 and 48273
1 ONE
Quick-Flex®
recessed-ceiling
wiring is faster
and easier
to install than
MC Cable® or other
modular wiring
systems. With only three basic components, the
Quick-Flex system snaps together in a fraction of the time it
takes to wire a fixture with MC Cable. There is no need for
tools, factory estimating or drawing services. Due to faster
installation, labor costs are dramatically reduced, cutting
down the total job cost.
The Quick-Flex system is ideal for wiring lay-in troffers,
parabolics, downlights, indirect fixtures and emergency lighting
equipment in office buildings, schools and retail stores.
Quick-Flex Standard Features
• The Quick-Flex fixture combo is shipped standard with an
access plate (as shown in the photo below). These access
plates have one pre-punched knockout to speed the
installation of Lithonia troffers and parabolics. For downlights or
non-Lithonia fixtures, discard access plate and install fixture
cable directly to any 1/2” knockout.
• UL Listed autoground – Fixtures are grounded
automatically as soon as the access plate is
snapped in place. No ground leads to connect.
• Auto-latching springs allow for an easy, secure connection and
prevent accidental disengagement.
Factory-Installed Combo Option
The Quick-Flex fixture cable (QFC) can be prewired to the fixture
in the factory. Both the fixture and Quick-Flex cable are shipped
together. This reduces the amount of time spent sorting materials
at the job site. It also cuts on-site disposal costs. This option is
ideal for jobs with 100 or more fixtures of the same type, using the
same Quick-Flex fixture cable.
See page 3 for ordering information.
Ask your local
Acuity Brands Lighting
representative for
your RELOC 1-2-3
price guarantee.
TWO 2
Quick-Flex Wiring is
Easy to Estimate
1) One QFC cable per fixture
2) One QC converter per circuit run
3) 10% QE cables and 3% QS splitters (spare parts)
Dust covers
are not included
with combo
option and must
be ordered
separately.
Switching Solutions
If MC Cable is used
between switches,
Quick-Flex wiring can
provide a simple and
efficient link from the
switchbox to the fixtures
on the switched circuit.
For best results, install
Quick-Flex switch drops
during the rough-in stage.
Add a Quick-Flex extender
between the switch drops
during the finish phase
when the fixtures and
QFC cables are installed.
35%
Cost Savings = ______
MC Cable
Quick-Flex
Materials
$385.00
$545.00
Labor
$677.00
$136.00
Total*
$1062.00
$681.00
* Based on a typical single-circuit, 30-fixture application
on 10-foot centers with a $55/hr. labor rate (USD).
35%
Savings
On Total
Installed
Cost
How To Order Fluorescent Combo Option
Lithonia Lighting fixture with Quick-Flex fixture cable attached and prewired.
Example: RELOC QFC277 12/3G11 becomes luminaire option QFC311GAB
2SP8 G 3 32 A12 347 GEB10IS QFC311GAB
Specifying wiring option:
Wiring Option 2 conductors (1 hot) ex: QFC2 (length) xx 3 conductors (2 hot) ex: QFC3 (length) xx
A
All ballasts/inverters on "A" circuit.
B
All ballasts/inverters on "B" circuit.
AB
Outboard lamps on "A", inboard on "B"
(If fixture contains 2 ballasts plus an
inverter, the inverter will be located at
the access plate. Not connected to a
QFC supplied circuit.)
AE
NW
Access plate with knockouts installed
in fixture. RELOC included with fixture,
not wired.
All ballast(s) on "A", inverter on "B". Access plate with knockouts installed
in fixture. RELOC included with fixture,
not wired.
3 THREE
OnePass® open-ceiling wiring simplifies
the installation of high bay fixtures.
Traditional hardwiring requires three or more passes to install conduit, pull wire and hang fixtures. Using the OnePass
system, only three basic components and one pass are needed. Faster installation reduces labor costs and the total job cost.
Plus, there is no need for factory estimating or drawing services.
The OnePass system is ideal for installing HID­­and fluorescent fixtures in manufacturing facilities, warehouses, retail
facilities and any other open-ceiling fixture applications.
OnePass Standard Features
• The OnePass system is listed for open accessible
ceilings and dry locations, meeting or exceeding the
UL 183 and 22.2 203.1 requirements, the National
Electrical Code and Canadian Standards.
• All components are easy to install and relocate,
featuring easy-to-grip cable heads and self-latching
springs that simply plug together.
OnePass Factory-Installed Option
Use the following guidelines to order fixtures with OnePass pre-installed.
• Add OCS to the description: Example IB 454 277 LP835A OCS. Consult
factory for other options.
•
For four or five conductor fixture drops, follow the same guidelines as
above, except tap positions must now be specified for the OCU product.
Example: OCU122N = 5' white cord with two hots, two dedicated
neutrals and a ground.
Example: OCU2310 = 10' white cord with two hots and one neutral.
• OnePass wiring is rated at 20A with 90ºC 12
AWG conductors. The OnePass OC2 cable also is
available in a 10AWG, 20A option to reduce voltage
drop on longer runs.
• All components are keyed to prevent different
voltages from connecting, and color-coded cable
heads allow for easy identification.
25%
Savings
On Total
Installed
Cost
FOUR 4
NEW
Circuit Selection at Every Fixture
Position 1
G 1 2 3 N
The OCS is a polarized plug-in connection for industrial
fixtures, featuring a patented thumbslide action. Just
choose the desired hot conductor(s) needed to
energize each fixture. Simply slide the circuit selector
to position 1, 2 or 3 and plug the fixture into the
system. No more worrying about coordinating
different-circuited fixtures. The OCS permits removal of
any fixture from the branch circuit without additional
components or interruption in the branch circuit.
All cables now available
in custom colors.
For details, contact the factory
at 1-800-541-4750.
25%
Cost Savings = ______
Pipe & Wire
OnePass
Materials
$700.00
$1267.00
Labor
$2062.00
$825.00
Total*
$2762.00
$2092.00
* Based on a typical single-circuit, 30-fixture application
on 20-foot centers with a $55/hr. labor rate (USD).
Ask your local Acuity Brands Lighting
representative for your Reloc
1-2-3 price guarantee.
OnePass Wiring is Easy to Estimate
1) One OCS per fixture
2) One OC2 cable for each fixture
3) One OC per circuit run
5 FIVE
Quick-Flex® Components
Recessed-Ceiling Lighting System
Example: QC120 12/3G
QC
QC - Converter
Provides interface between
hardwiring and Quick-Flex wiring
at the homerun location.
12/3G
Family
Voltage
Size and no. of conductors
QC Q
uickFlex
converter
120 120V
277 277V
347 347V
12/3G
Family
Voltage
Size and no. of conductors
QSFC Q
uickFlex
starter
fixture cable
120 120V
277 277V
347 347V
12/2G
12/3G
QSFC
QSFC - Starter Fixture
Cable1
Combination of converter (QC)
and fixture cable (QFC).
Length
Optional ground lead
09 9 feet G No. 18 AWG ground
11 11 feet
lead dropped to
13 13 feet
fixture (REQUIRED
15 15 feet
IN CANADA)
QFC
QFC - Fixture Cable1
Male/female cable provides
power from fixture to fixture.
Access plate is preattached.
Family
Voltage
Size and no. of conductors
Length
Optional ground lead
120 120V
277 277V
347 347V
12/2G
12/3G
09 9 feet
11 11 feet
13 13 feet
15 15 feet
G No. 18 AWG ground
lead dropped to
fixture (REQUIRED
IN CANADA)
Family
Voltage
Size and no. of conductors
Length
QE Q
uickFlex
extender
120 120V
277 277V
347 347V
12/2G
12/3G
09 9 feet
11 11 feet
15 15 feet
21 21 feet
Voltage
Size and no. of conductors
120 120V
277 277V
347 347V
1LEVEL
2LEVEL
1LEVEL/N
QFC Q
uickFlex
fixture
cable
QE
QE - Extender
Male/female cable provides
additional length anywhere within
the system.
QSD
QSD - Switch Drop
Provides local switched power for
fixtures as well as the ability to
carry on unswitched power through
the use of a QE.
Family
QSD Q
uickFlex
switch
drop
QPT
QPT - Power Tee
Provides hardwire connection to
any electrical device.
Family
QPT Q
uickFlex
power
tee
12/3G
Voltage
Size and no. of conductors
Length
120 120V
277 277V
347 347V
12/3G
01 1 foot
09 9 feet
15 15 feet
QS
QS - Splitter
Male/female component that can
be used anywhere in the system.
Separates branch circuit into two
directions.
SIX
6
Length
01 1 foot
09 9 feet
12/3G
Family
Voltage
Size and no. of conductors
QS Q
uickFlex
splitter
120 120V
277 277V
347 347V
12/3G
Quick-Flex Dust Cover
Dust cover is required to protect unused ports
in a RELOC system per NEC Article 604.7.
QUICK FLEX Dust cover J50
NOTES:
1
Furnished with poke home connectors
for easy connection to fixture wires.
OnePass® Components
Open-Ceiling Lighting System
Example: OC 277 12/4G
OC
12/4G
Family1
OC OnePass
converter
OSC2
Family1
Voltage
120
208
240
277
347
480
OSC2 OnePass
starter
cable
Size and no. of conductors3
Voltage
120
208
240
277
347
480
12/4G
120V
208V2
240V2
277V
347V
480V2
Cable length
Size and no. of conductors
120V
208V2
240V2
277V
347V
480V2
09
15
21
25
31
12/2G
12/3G
12/4G
10/2G
10/3G
10/4G
9 feet
15 feet
21 feet
25 feet
31 feet
OC - Converter
Provides interface between
hardwiring and RELOC wiring at
homerun location.
OSC2 - Starter Cable
Provides interface between
hardwiring and RELOC wiring system.
OC2
Family1
Voltage
OC2 OnePass
twoport
cable
120
208
240
277
347
480
Size and no. of conductors
Cable length
12/2G
12/3G
12/4G
10/2G
10/3G
10/4G
120V
208V2
240V2
277V
347V
480V2
09
15
21
25
31
9 feet
15 feet
21 feet
25 feet
31 feet
OCS
Family4
Voltage
OCS OnePass
cord
with
circuit
selector
120
208
240
277
347
480
120V
208V2
240V2
277V
347V
480V2
Cable length
Cord colors5
05 5 feet
10
10 feet
15
15 feet
20
20 feet
WH White cord
BK Black cord
OC2 - Two-Port Cable
Provides feed-through and tap in
one component. Acts as an extension
cable between fixture connections.
OCS - Circuit Selector
A polarized plug-in connector for
industrial fixtures. Allows on-site circuit
selection of desired hot conductor(s).
Prewired by fixture manufacturer or
field installed by contractor.
OCU
Family1,4
OCU OnePass
cord
unselectable
Tap
position
Voltage
120 120V
TAP2 2
208 208V2 TAP12 1 and 2
240 240V2 TAP34 3 and 4
347 347V
TAP1 1
480 480V2 TAP3 3
TAP23 2 and 3
TAP123 1, 2 and 3
Cord colors5
Cable length
05
10
15
20
5 feet
10 feet
15 feet
20 feet
WH White cord
BK Black cord
OCU - Cord Unselectable
A polarized, non-circuit selectable
plug-in connection for industrial
fixtures. Prewired by fixture manufacturer or field installed by contractor.
OD
Family1
OD OnePass
drop
cable
Voltage
120
208
240
277
347
480
Size and no. of conductors
12/2G
12/3G
12/4G
120V
208V2
240V2
277V
347V
480V2
OSS
Family1
OSS OnePass
splitter
splice
Cable length
05
10
15
20
5 feet
10 feet
15 feet
20 feet
OD - Drop Cable
Allows miscellaneous devices (exits,
etc.) to become part of the system.
12/4G
Voltage
120
208
240
277
347
480
Size and no. of conductors3
12/4G
120V
208V2
240V2
277V
347V
480V2
OnePass Dust Cover
Dust cover is required to protect unused ports
in a RELOC system per NEC Article 604.7.
RDC3 METAL Dust cover CSA/UL J50
OSS - Splitter Splice
Male/female component that can be
used anywhere in the system.
Separates branch circuit into two
directions.
NOTES:
1
For two neutral applications, specify 2N (10/4G and 12/4G only).
Consult factory for other options.
Please consult factory when ordering 208V, 240V or 480V.
Use 12/4G product for 10GA, 20A systems.
16AWG rubberized cord rated for 600V, 105ºC with fully rated ground conductor.
White cord standard. Black cord requires longer lead time.
2
3
4
5
7 SEVEN
System 820
Specialty Power and Lighting System
Example: CD 120 F
CD
CD - Circuit Distributor
Provides interface between
hardwiring and RELOC wiring
system.
Family
CD
Voltage
No. of conductors
120 120V D Three
277 277V E Four
347 347V F Five
CE
CE - Cable Extender
Male/female cable that provides
additional length anywhere
throughout the RELOC system.
U
Family
Voltage
CE
120 120V
277 277V
347 347V
No. of conductors
D Three
E Four
F Five
Male/female cable, provides power
from fixture to fixture. Attaches
to access plate or through 1/2”
trade-size knockout by means of
poke home connectors.
Family
Voltage
SSC
120 120V
277 277V
347 347V
SS
SS - Splitter Splice
Used to split branch circuit into
two directions in commercial or
power applications.
Family
Voltage
SS
120120V
277277V
347347V
CSU
CSU - Circuit Selector
Unit
Provides wiring of any device
through 1/2" trade-size
knockout. CSU uses No. 12
AWG leads, allowing full circuit
access.
Family
CSU
Factory
keying
U
Options
Cable
length
09
11
15
21
25
9 feet
11 feet
15 feet
21 feet
25 feet
IGW Isolated ground
wire; available
with 120V and F
conductor only
2NTwo circuit, two
neutral; F conductors only
U
SSC
SSC - Standard
Selector Cable
Options
IGW Isolated ground
wire; available
with 120V and F
conductor only
2NTwo circuit, two
neutral; F conductors only
Voltage
No. of conductors
D Three
E Four
F Five
Factory
keying
U
F
U
No. of conductors
Factory
keying
F Five
U
F
U
No. of conductors
Factory
keying
120 120V F Five
277 277V
347 347V
U
Options
Cable
length
09
11
13
15
9 feet
11 feet
13 feet
15 feet
Options
IGW Isolated ground
wire; available with
120V and F conductor only
2NTwo circuit, two
neutral; F conductors only
Options
IGW Isolated ground wire;
available with 120V
and F conductor only
2NTwo circuit, two
neutral; F conductors
only
820 Dust Cover
Dust cover is required to protect unused ports in a RELOC system per NEC Article 604.7.
RDC3 METAL Dust cover CSA/UL J50
EIGHT
8
2NTwo circuit, two
neutral; F conductors only
G Ground lead with
lug terminal
(REQUIRED IN
CANADA)
System 820
Specialty Power and Lighting System
Number of
duplexes
(blank) One
2 Two
DUP
120
Series
Voltage
DUP
120 120V
A
Hot receptacle
position
Interface component
F
Family
No. of
conductors
FFive1
Voltage
Family
RRCA2
Voltage
120 120V
208 208V
347 347V
480 480V
011 foot
055 feet
Options
IGW Isolated ground
wire; available
with E and F conductors only (add
only if required)
1 One
2 Two
3 Three
Tap position
Drop type
1 1
2
2
3
3
121 and 2
131 and 3
232 and 3
123 1, 2 and 3
A Armored
Options
IGWIsolated ground
wire; available
with 120V; E and
F conductors only
Cable
2N
Two circuit, two
length
neutral; F conductors only
01 1 foot
03 3 feet
09 9 feet
15 15 feet
F
RRCA
DUP - Duplex Receptacle
Cable
length
The DUP is a prewired power
receptacle outlet box that integrates
with a RELOC system. The DUP can
be used to manage phase loading
on power receptacle applications.
Pre-order the appropriate number of
receptacles for each circuit prewired
from the factory.
A
PT
120 120V
277 277V
347 347V
A Armored
D Three
E Four
F Five
PT Power tee1
DC Drop cable
PT
Drop type
No. of
conductors
No. of
conductors
FFive
Tap position
123 1, 2 and 3
(120V or 277V)
1234 1, 2, 3 and 4
(208V or 480V)
05
WH
Cable length
Cord color
05 5 feet
WH White
PT - Power Tee
Provides hardwire connections to
any electrical device.
RRCA - Replacement
RELOC Cord Assembly
Ideal for retrofitting projects done with
old RELOC system. Prewired by fixture
manufacturer or field installed
by the contractor.
U
DC
Family
Voltage
DC
120 120V
277 277V
347 347V
No. of
conductors
D Three
EFour
FFive
Factory keying
U
Cable length
09
11
13
15
9 feet
11 feet
13 feet
15 feet
Options
IGW Isolated ground
wire; available
with 120V and F
conductor only
2N Two circuit, two
neutral; F conductors only
DC - Drop Cable
Provides integration of other electrical
devices into the 820 system, such as
power outlets and power strips.
NOTES:
1
2
Power Tee (PT) is available in five-conductor only with DUP product.
RRCA is sold only with white cord and five-wire configuration.
9 NINE
REDUC
E
USE
RE
Y
REC CLE
Reduce, Reuse, Recycle. . .RELOC®
RELOC products are a greener solution than traditional wiring. RELOC products
minimize installation time and construction waste while maximizing productivity,
reusability and the use of recycled materials.
Please see www.acuitybrandslighting.com/sustainability for more information.
One Lithonia Way, Conyers, GA 30012 | TEL 800.241.4750 | FAX 770.808.8650 | www.relocwiring.com
© 2011 Acuity Brands Lighting, Inc., All Rights Reserved. 06/11 R6980 Form No. 670.208