ACS713 - Allegro Microsystems
... solutions for DC current sensing in industrial, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. The devi ...
... solutions for DC current sensing in industrial, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. The devi ...
M V L I
... event that a line-to-ground fault is detected, or that the safety system has otherwise been compromised. The Mark V employs a unique monitoring technique to simultaneously analyze the line-to-ground impedance of both output legs of an IPS. It divides the line voltage by the lower of the two ground i ...
... event that a line-to-ground fault is detected, or that the safety system has otherwise been compromised. The Mark V employs a unique monitoring technique to simultaneously analyze the line-to-ground impedance of both output legs of an IPS. It divides the line voltage by the lower of the two ground i ...
High performance Flying Capacitor based Multilevel Inverter fed
... output voltage waveform. It is assumed that the modulating signal varies from + 2 to − 2. The amplitudes of the 4 carrier waves vary from 0 to 1, 1 to 2, in the positive half cycle of the modulating signal, and from 0 to − 1, and − 1 to − 2 in the negative half cycle. In the positive half cycle the ...
... output voltage waveform. It is assumed that the modulating signal varies from + 2 to − 2. The amplitudes of the 4 carrier waves vary from 0 to 1, 1 to 2, in the positive half cycle of the modulating signal, and from 0 to − 1, and − 1 to − 2 in the negative half cycle. In the positive half cycle the ...
OC Series - Haefely Hipotronics
... switch and rotary output voltage control in addition to input power and overload circuits. ...
... switch and rotary output voltage control in addition to input power and overload circuits. ...
D380 Installation and Operation Manual
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
Introduction - EECG Toronto
... Figure 8 – (a) Current Steering Amplifier Cell, (b) VCO using a three-stage CSA ring oscillator………………………………………………………………………...pg. 14 Figure 9 – Measure VCO Performance for [6]………………………………… pg. 16 Figure 10 – Basic Charge Pump……………………………………………….. pg. 17 Figure 11 – PLL with Voltage Doubler inserted……… ...
... Figure 8 – (a) Current Steering Amplifier Cell, (b) VCO using a three-stage CSA ring oscillator………………………………………………………………………...pg. 14 Figure 9 – Measure VCO Performance for [6]………………………………… pg. 16 Figure 10 – Basic Charge Pump……………………………………………….. pg. 17 Figure 11 – PLL with Voltage Doubler inserted……… ...
Page 276 - Stoody Industrial and Welding Supply
... AIR-PLASMA CUTTING SYSTEMS – Thermal Arc power supplies deliver exceptionally smooth, powerful cutting current. SMART START™, AUTO PILOT RESTART – Instantly reignites pilot arc when the cutting arc is interrupted, such as when cutting expanded metal. 1TORCH™ SERIES 70° HAND TORCH - WITH A 20 Ft. CAB ...
... AIR-PLASMA CUTTING SYSTEMS – Thermal Arc power supplies deliver exceptionally smooth, powerful cutting current. SMART START™, AUTO PILOT RESTART – Instantly reignites pilot arc when the cutting arc is interrupted, such as when cutting expanded metal. 1TORCH™ SERIES 70° HAND TORCH - WITH A 20 Ft. CAB ...
C5 Manual.indd
... volt source to make the amplifier operational. Typically, remote turn-on leads are provided at the head unit that will turn on and off the amplifier in correspondence with the source. This means you will most likely have to remove the head unit from the dash to find the source +12V output wire. Once th ...
... volt source to make the amplifier operational. Typically, remote turn-on leads are provided at the head unit that will turn on and off the amplifier in correspondence with the source. This means you will most likely have to remove the head unit from the dash to find the source +12V output wire. Once th ...
MV Switchgear 25kVMetal-Clad Outdoor
... type that operates from the 5 ampere secondary output of the current transformers. The device shall provide ANSI 50/51 protective functions for each of the three phases, and ANSI 50/51N or 50/51G ground fault protection functions as shown on the drawings and as determined by the coordination study. ...
... type that operates from the 5 ampere secondary output of the current transformers. The device shall provide ANSI 50/51 protective functions for each of the three phases, and ANSI 50/51N or 50/51G ground fault protection functions as shown on the drawings and as determined by the coordination study. ...
micom P342 / 343 / 344 / 345
... can be used for loss of grid or load shedding applications. The number of frequency averaging cycles, number of protection iterations, operating mode – fixed or rolling window and direction of operation can be set to suit the application. Power protection The power protection element provides two st ...
... can be used for loss of grid or load shedding applications. The number of frequency averaging cycles, number of protection iterations, operating mode – fixed or rolling window and direction of operation can be set to suit the application. Power protection The power protection element provides two st ...
ONET8511T 数据资料 dataSheet 下载
... The voltage drop across the internal photodiode supply-filter resistor is monitored by the bias and RSSI control circuit block in the case where a PIN diode is biased using the FILTER pins. If the dc input current exceeds a certain level then it is partially cancelled by means of a controlled curren ...
... The voltage drop across the internal photodiode supply-filter resistor is monitored by the bias and RSSI control circuit block in the case where a PIN diode is biased using the FILTER pins. If the dc input current exceeds a certain level then it is partially cancelled by means of a controlled curren ...
Graduate Category: Engineering and Technology Degree Level: Ph.D Abstract ID# 1016
... voltage is regulated by low-dropout (LDO) regulator. Other noises generated by each PLL block are filtered by ALF. Therefore, high frequency noise of the VCO's control voltage is eliminated and stable control voltage decreases PLL jitter. The LDO regulator provides 0.8V output, -83 dB PSRR with PLL ...
... voltage is regulated by low-dropout (LDO) regulator. Other noises generated by each PLL block are filtered by ALF. Therefore, high frequency noise of the VCO's control voltage is eliminated and stable control voltage decreases PLL jitter. The LDO regulator provides 0.8V output, -83 dB PSRR with PLL ...
A Static Phase Offset Reduction Technique for Multiplying Delay
... In high-speed data communication systems, on-chip clock multiplication plays a very important role. Phaselocked loops (PLLs) and multiplying delay locked loops (MDLLs) are widely employed to generate the accurate high-frequency on-chip timing signals from a low frequency, low jitter clock source. If ...
... In high-speed data communication systems, on-chip clock multiplication plays a very important role. Phaselocked loops (PLLs) and multiplying delay locked loops (MDLLs) are widely employed to generate the accurate high-frequency on-chip timing signals from a low frequency, low jitter clock source. If ...
AN-770 APPLICATION NOTE
... designing isolators into the digital signal path between the transceivers and the local CAN bus controller. The system side of the CAN bus transceivers use digital logic level signals of 0 V to 5 V or 0 V to 3 V, and typically connect to a CAN controller or processor. iCoupler isolators contain inpu ...
... designing isolators into the digital signal path between the transceivers and the local CAN bus controller. The system side of the CAN bus transceivers use digital logic level signals of 0 V to 5 V or 0 V to 3 V, and typically connect to a CAN controller or processor. iCoupler isolators contain inpu ...
MAX9155 Low-Jitter, Low-Noise LVDS Repeater in an SC70 Package General Description
... termination of 100Ω. Interconnects with a characteristic impedance and termination of 90Ω to 132Ω impedance are allowed, but produce different signal levels (see Termination). Use cables and connectors that have matched differential impedance to minimize impedance discontinuities. Avoid the use of u ...
... termination of 100Ω. Interconnects with a characteristic impedance and termination of 90Ω to 132Ω impedance are allowed, but produce different signal levels (see Termination). Use cables and connectors that have matched differential impedance to minimize impedance discontinuities. Avoid the use of u ...