P 3 Owner`s Guide
... Balanced connections will give you the best sound. If your source components have balanced XLR output jacks, we recommend that you connect them to these inputs. Refer to the Balanced and Unbalanced Lines in the Technically Speaking section for additional information about why we recommend using bala ...
... Balanced connections will give you the best sound. If your source components have balanced XLR output jacks, we recommend that you connect them to these inputs. Refer to the Balanced and Unbalanced Lines in the Technically Speaking section for additional information about why we recommend using bala ...
FAN2001/FAN2002 1A High-Efficiency Step-Down DC-DC Converter F
... input capacitor, the inductor, and the output capacitor as close as possible to the integrated circuit terminals. In order to minimize voltage stress to the device resulting from ever present switching spikes, use an input bypass capacitor with low ESR. Note that the peak amplitude of the switching ...
... input capacitor, the inductor, and the output capacitor as close as possible to the integrated circuit terminals. In order to minimize voltage stress to the device resulting from ever present switching spikes, use an input bypass capacitor with low ESR. Note that the peak amplitude of the switching ...
OP400
... A dual instrumentation amplifier that consumes less than 33 mW of power per channel is shown in Figure 30. The linearity of the instrumentation amplifier exceeds 16 bits in gains of 5 to 200 and is better than 14 bits in gains from 200 to 1000. CMRR is above 115 dB (G = 1000). Offset voltage drift i ...
... A dual instrumentation amplifier that consumes less than 33 mW of power per channel is shown in Figure 30. The linearity of the instrumentation amplifier exceeds 16 bits in gains of 5 to 200 and is better than 14 bits in gains from 200 to 1000. CMRR is above 115 dB (G = 1000). Offset voltage drift i ...
mx321 automatic voltage regulator (avr)
... S1, S2 on the AVR, (see generator wiring diagram for details). The DROOP adjustment is normally preset in the works to give 5% voltage droop at full load zero power factor. Clockwise increases the amount of C.T. signal injected into the AVR and increases the droop with lagging power factor (cos Ø). ...
... S1, S2 on the AVR, (see generator wiring diagram for details). The DROOP adjustment is normally preset in the works to give 5% voltage droop at full load zero power factor. Clockwise increases the amount of C.T. signal injected into the AVR and increases the droop with lagging power factor (cos Ø). ...
BD6962FVM
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
a 250 MHz, 10 ns Switching Multiplexers w/Amplifier AD8170/AD8174
... current feedback output amplifier whose gain can be programmed via external resistors and is capable of delivering 50 mA of output current. They offer –3 dB signal bandwidth of 250 MHz and slew rate of greater than 1000 V/µs. Additionally, the AD8170 and AD8174 have excellent video specifications wi ...
... current feedback output amplifier whose gain can be programmed via external resistors and is capable of delivering 50 mA of output current. They offer –3 dB signal bandwidth of 250 MHz and slew rate of greater than 1000 V/µs. Additionally, the AD8170 and AD8174 have excellent video specifications wi ...
Advanced PV System Design and Installation
... This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides do not need fire service approval. • Electrical diagram showing PV array configuration, wir ...
... This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides do not need fire service approval. • Electrical diagram showing PV array configuration, wir ...
Analog Devices Welcomes Hittite Microwave Corporation
... [1] See power output vs. tuning voltage graph for power slope. [2] Actual spur level is dependent on loop parameters and will increase at division ratios closest to integer boundaries. ...
... [1] See power output vs. tuning voltage graph for power slope. [2] Actual spur level is dependent on loop parameters and will increase at division ratios closest to integer boundaries. ...
ADS831 数据资料 dataSheet 下载
... are used to create a common-mode voltage (VCM) of approximately +2.5V to bias the inputs of the driving amplifier. Using the OPA681 on a single +5V supply, its ideal common-mode point is +2.5V. This coincides with the recommended common-mode input level for the ADS831 thus, obviating the need for a ...
... are used to create a common-mode voltage (VCM) of approximately +2.5V to bias the inputs of the driving amplifier. Using the OPA681 on a single +5V supply, its ideal common-mode point is +2.5V. This coincides with the recommended common-mode input level for the ADS831 thus, obviating the need for a ...
Section 4-2_Surge
... of 160 µs minimum (260 µs maximum), and shall have a short circuit current waveshape in accordance with Figure 4.3 having a front time (tf) of 10 µs maximum (5 µs minimum)and a decay time (td) of 160 µs minimum (210 µs maximum). The peak voltage shall be at least 1500 V (1650 V maximum) and the peak ...
... of 160 µs minimum (260 µs maximum), and shall have a short circuit current waveshape in accordance with Figure 4.3 having a front time (tf) of 10 µs maximum (5 µs minimum)and a decay time (td) of 160 µs minimum (210 µs maximum). The peak voltage shall be at least 1500 V (1650 V maximum) and the peak ...
ELITE 15 PF OWNER`S MANUAL
... as a vector load. Simply put, the type of power supplies or electronic circuits connected to the Elite-15 PF will have an effect on its circuit breakers perceived current load, and therefore, when it will trip. Though the benefits of power factor correction far outweigh the small reduction in continu ...
... as a vector load. Simply put, the type of power supplies or electronic circuits connected to the Elite-15 PF will have an effect on its circuit breakers perceived current load, and therefore, when it will trip. Though the benefits of power factor correction far outweigh the small reduction in continu ...
Regent VL71i - Victor Lighting
... tappings are shown on the control gear and the limits are shown on the rating plate. If the equipment is located in high or low voltage sections of the system, an appropriate voltage tap should be selected, but care must be taken to log or mark the equipment so that the tapping is re-set if the equi ...
... tappings are shown on the control gear and the limits are shown on the rating plate. If the equipment is located in high or low voltage sections of the system, an appropriate voltage tap should be selected, but care must be taken to log or mark the equipment so that the tapping is re-set if the equi ...
ATE Quick Start Guide
... operating mode is indicated by LED mode indicators at the front panel (Figure 1). Operating mode crossover is automatic and may be monitored remotely by means of a flag signal, available at the rear programming connector. The power supply features “full range” output control by means of 10-turn, hig ...
... operating mode is indicated by LED mode indicators at the front panel (Figure 1). Operating mode crossover is automatic and may be monitored remotely by means of a flag signal, available at the rear programming connector. The power supply features “full range” output control by means of 10-turn, hig ...
BD6964FVM
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
example
... space. The type of transmission medium used is important, since it determines the maximum rate, in terms of binary digits (bits) per second or bps, that data can be transmitted. Some of the more common types of transmission media are discussed in the following sections. 2.2.1 Two-wire open lines A t ...
... space. The type of transmission medium used is important, since it determines the maximum rate, in terms of binary digits (bits) per second or bps, that data can be transmitted. Some of the more common types of transmission media are discussed in the following sections. 2.2.1 Two-wire open lines A t ...