• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
When power is supplied by V or V , the
When power is supplied by V or V , the

... The Teridian 73S8009C is a versatile power management and single smart card interface circuit that is ideally suited for smart card reader products that are battery and/or USB bus-powered. In addition to its EMV 4.1 and ISO-7816-3 compliant smart card-to-host interface circuitry; it provides control ...
BD1482EFJ
BD1482EFJ

... Use of the IC in excess of absolute maximum ratings such as the applied voltage or operating temperature range may result in IC damage. Assumptions should not be made regarding the state of the IC (short mode or open mode) when such damage is suffered. A physical safety measure such as a fuse should ...
BD1484EFJ
BD1484EFJ

... Use of the IC in excess of absolute maximum ratings such as the applied voltage or operating temperature range may result in IC damage. Assumptions should not be made regarding the state of the IC (short mode or open mode) when such damage is suffered. A physical safety measure such as a fuse should ...
244-33LOADS
244-33LOADS

... ELEMENTS ELECTRONIC DEVICES SPECIAL PROCESS EQUIPMENT RESISTIVE LOADS & INDUCTIVE LOADS ...
Document
Document

... The rapid, spontaneous transfer of electrostatic charge induced by a high electrostatic field. Usually, the charge flows through a spark between two bodies at different electrostatic potentials as they approach one another. (from ESD-ADV1.0-1994) ...
antennas - N8PR-Pete Rimmel`s Homepage
antennas - N8PR-Pete Rimmel`s Homepage

... trapped antennas. They cover the 10-15-20 Meter Bands but not the WARC bands 12 & 17 M. The reason that there are so many is that they have been around much longer, since they were designed before the WARC bands were created. Also, they are in demand by contesters where only the non-WARC bands are u ...
ANTENNAS: PART II
ANTENNAS: PART II

... trapped antennas. They cover the 10-15-20 Meter Bands but not the WARC bands 12 & 17 M. The reason that there are so many is that they have been around much longer, since they were designed before the WARC bands were created. Also, they are in demand by contesters where only the non-WARC bands are u ...
AP1539
AP1539

... General Description ...
Protection Relays Guide 2012
Protection Relays Guide 2012

... Application • Phase and earth fault dual-powered overcurrent protection applicable in MV substations • Applicable in systems where auxiliary supply voltage may be interrupted or lost • Auxiliary protection of HV/MV transformers Interaction with Circuit Breaker • Tripping a CB when powered by cur ...
File Ref.No.72742/GA - IV - J1/2014/Admn  UNIVERSITY OF CALICUT
File Ref.No.72742/GA - IV - J1/2014/Admn UNIVERSITY OF CALICUT

UNIT 1
UNIT 1

... trapped antennas. They cover the 10-15-20 Meter Bands but not the WARC bands 12 & 17 M. The reason that there are so many is that they have been around much longer, since they were designed before the WARC bands were created. Also, they are in demand by contesters where only the non-WARC bands are u ...
19/23-5SS
19/23-5SS

... technician certified by Eaton and Carrier as a commissioner for the LCX9000 VFD. Proper commissioning forms should be completed for submission to Eaton. The entire VFD parameter set should be collected using the Eaton XDrive utility program (available from Eaton) and submitted to Eaton as part of st ...
273 Branchport Avenue Long Branch, N.J.
273 Branchport Avenue Long Branch, N.J.

BD8963EFJ
BD8963EFJ

... 5. Considerations on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including ...
AB2 Driver User Manual D/N: AB02458000-00  REV: C
AB2 Driver User Manual D/N: AB02458000-00 REV: C

... provisions constitute the exclusive remedy of the Purchaser for product defects or any other claim of liability in connection with the purchase or use of NM products. This warranty policy applies only to NM products purchased directly from NM or from an authorized NM distributor or representative. T ...
ADP1712-14
ADP1712-14

Measurement of High Voltage - Department of Electrical Engineering
Measurement of High Voltage - Department of Electrical Engineering

... potential). If both electrodes are at equal high voltage of opposite polarity (i.e. + ½ V and - ½ V), as in a symmetrical gap, then the polarity has no effect. Figure 6.4 shows these breakdown voltage variations. In the case of the asymmetrical gap, there are two breakdown characteristics; one for t ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anticrime systems; safety equipment; and medical equipment not specifically designed for life support. “Specific”: Aircraft; aerospace equipment; submersible repeaters; nuclea ...
Power Plant “Horror Stories” - Beckwith Electric Co., Inc.
Power Plant “Horror Stories” - Beckwith Electric Co., Inc.

... during ground fault conditions. If the generator is solidly grounded (not usually the case), it will deliver a very high current to a SLG (single-line-to-ground) fault at its terminals, accompanied by a 58% reduction in the phase-to-phase voltages involving the faulted phase and a modest neutral vol ...
IECEx 800 Enhanced Core Processor Certificate
IECEx 800 Enhanced Core Processor Certificate

... Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: Description The signal processing device is used for the connection of sensors to transmitters. The electrical components are completely encapsulated in a plastic housing. On the top of the housing terminals for th ...
Circuit Breakers Supplementary Protectors
Circuit Breakers Supplementary Protectors

... that when they trip, they rely upon the zero-crossing characteristics of the current waveform for complete circuit interruption. Under these conditions, the let-through energy can be quite high and components affected by the fault, which might include a critical load, will be subject to a high level ...
mv controller - Siemens Industry, Inc.
mv controller - Siemens Industry, Inc.

60-W, 24-V, High-Efficiency Industrial Power
60-W, 24-V, High-Efficiency Industrial Power

... The TMP302 is a temperature switch in a micro package (SOT563). The TMP302 offers low power (15-μA maximum) and ease-of-use through pin selectable trip points and hysteresis. These devices require no additional components for operation. They can function independent of microprocessors or microcontro ...
LSA 46.2 / 47.1 - 4 POLE
LSA 46.2 / 47.1 - 4 POLE

... - Away from humidity : in conditions of relative humidity of more than 90%, the machine insulation can drop very rapidly, to just above zero at around 100%; monitor the state of the anti-rust protection on unpainted parts. For storage over an extended period, the machine can be placed in a sealed en ...
AP7167  1.2A LOW DROPOUT REGULATOR WITH POK Description
AP7167 1.2A LOW DROPOUT REGULATOR WITH POK Description

< 1 ... 77 78 79 80 81 82 83 84 85 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report