Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Multi-Module
... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
HMC344LH5 数据资料DataSheet下载
... The HMC344LH5 is a broadband non-reflective GaAs MESFET SP4T switch in a hermetic SMT leadless package. Covering DC to 12 GHz, this switch offers high isolation and low insertion loss. This switch also includes an on board binary decoder circuit which reduces the required logic control lines to two. ...
... The HMC344LH5 is a broadband non-reflective GaAs MESFET SP4T switch in a hermetic SMT leadless package. Covering DC to 12 GHz, this switch offers high isolation and low insertion loss. This switch also includes an on board binary decoder circuit which reduces the required logic control lines to two. ...
AP7176B Description Pin Assignments
... The regulator ground pin should be connected to the external circuit ground to reduce voltage drop caused by trace impedance. Ground plane is generally used to reduce trace impedance. Wide trace should be used for large current paths from VIN to VOUT, and load circuit. Place the R1, R2, and C1 (opti ...
... The regulator ground pin should be connected to the external circuit ground to reduce voltage drop caused by trace impedance. Ground plane is generally used to reduce trace impedance. Wide trace should be used for large current paths from VIN to VOUT, and load circuit. Place the R1, R2, and C1 (opti ...
Power Switching Devices and their Static Electrical Characteristics
... at the pn-ring junction for a given reverse bias voltage. Negatively charged glass film techniques are also employed to widen the scl near the surface, as shown in figures 3.1c and 3.1d. Multiple guard rings are sometimes employed for very high breakdown voltage devices. Similar techniques are exten ...
... at the pn-ring junction for a given reverse bias voltage. Negatively charged glass film techniques are also employed to widen the scl near the surface, as shown in figures 3.1c and 3.1d. Multiple guard rings are sometimes employed for very high breakdown voltage devices. Similar techniques are exten ...
Manual - Effective Solar
... Use a well regulated DC power supply that has an output voltage between 11 volts and 15 volts and can deliver the required current. If the supply is adjustable, make sure that the output voltage is adjusted to be between 11 volts and 15 volts. The inverter may shut down if the voltage is outside the ...
... Use a well regulated DC power supply that has an output voltage between 11 volts and 15 volts and can deliver the required current. If the supply is adjustable, make sure that the output voltage is adjusted to be between 11 volts and 15 volts. The inverter may shut down if the voltage is outside the ...
TL1963A-Q1 数据资料 dataSheet 下载
... 1.5 A of output current with a dropout voltage of 340 mV. Operating quiescent current is 1 mA, dropping to less than 1 mA in shutdown. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. In addition to fast transient response, the TL1963A regulato ...
... 1.5 A of output current with a dropout voltage of 340 mV. Operating quiescent current is 1 mA, dropping to less than 1 mA in shutdown. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. In addition to fast transient response, the TL1963A regulato ...
sam-1500c-12_owners_..
... and the current demand will start reducing. When the current reduces to less than 15A, the charger will exit current limit / Bulk Charge Stage (Point 2, Fig 2.1) and will output a fixed Float Voltage of 13.8V thereafter (Points 2 to 3 on the Voltage Curve in Fig 2.2). Battery’s intrinsic voltage wil ...
... and the current demand will start reducing. When the current reduces to less than 15A, the charger will exit current limit / Bulk Charge Stage (Point 2, Fig 2.1) and will output a fixed Float Voltage of 13.8V thereafter (Points 2 to 3 on the Voltage Curve in Fig 2.2). Battery’s intrinsic voltage wil ...
DF33642645
... One of the inputs of both FG_MOSs is biased mode for tuning the MOS (Vth) (basically hear I use positive bias voltage for NFGMOS and same negative bias voltage for PFGMOS) and another input is used as operational input. The design of the proposed circuit is typically characterized by the ratio (β) o ...
... One of the inputs of both FG_MOSs is biased mode for tuning the MOS (Vth) (basically hear I use positive bias voltage for NFGMOS and same negative bias voltage for PFGMOS) and another input is used as operational input. The design of the proposed circuit is typically characterized by the ratio (β) o ...
Data Sheets
... On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_ TH, and EN is low, the device enters startup after a 10ms internal delay. ...
... On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_ TH, and EN is low, the device enters startup after a 10ms internal delay. ...
AAT4686 数据资料DataSheet下载
... On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_ TH, and EN is low, the device enters startup after a 10ms internal delay. ...
... On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_ TH, and EN is low, the device enters startup after a 10ms internal delay. ...
NCP1250 - ON Semiconductor
... that can be used to sense an overvoltage condition on the adapter. If this pin is brought higher than the internal reference voltage Vlatch, then the circuit permanently latches off. The VCC pin is pulled down to a fixed level, keeping the controller latched. The latch reset occurs when the user dis ...
... that can be used to sense an overvoltage condition on the adapter. If this pin is brought higher than the internal reference voltage Vlatch, then the circuit permanently latches off. The VCC pin is pulled down to a fixed level, keeping the controller latched. The latch reset occurs when the user dis ...
KE2517881796
... series connected device whose function is to protect a sensitive industrial load from voltage sags.The voltage sag compensator, based on a transformer-coupled is connected in series to voltage source inverter, is among the most costeffective solution against voltage sags. To mitigate the problems ca ...
... series connected device whose function is to protect a sensitive industrial load from voltage sags.The voltage sag compensator, based on a transformer-coupled is connected in series to voltage source inverter, is among the most costeffective solution against voltage sags. To mitigate the problems ca ...
APPLICATION NOTE AT02876: Atmel REB212BSMA Hardware User Manual Atmel MCU Wireless Introduction
... Analog ground pins are to be routed to the paddle underneath the IC. The trace width has to be similar to the pad width when connecting the pads, and increase, if possible, in some distance from the pad. This measure will decrease the parasitic inductance as far as possible. Each ground pin should b ...
... Analog ground pins are to be routed to the paddle underneath the IC. The trace width has to be similar to the pad width when connecting the pads, and increase, if possible, in some distance from the pad. This measure will decrease the parasitic inductance as far as possible. Each ground pin should b ...
G044023238
... the dc capacitor CA and output filter (LB, CB) form as a third-order low-pass filter to filter out the switching harmonic in the output voltage. Hence, a lower capacitance dc capacitor CA of several tens of microfarads can be selected. 2.2 AC Buck Mode When the utility voltage is higher than the spe ...
... the dc capacitor CA and output filter (LB, CB) form as a third-order low-pass filter to filter out the switching harmonic in the output voltage. Hence, a lower capacitance dc capacitor CA of several tens of microfarads can be selected. 2.2 AC Buck Mode When the utility voltage is higher than the spe ...
These customisations are simple to carry out using the
... localised set of parameters that would better suit their needs. Up until the 2012 version of Revit MEP, the electrical template was very much a straight copy of the United State’s version of the same, and as such it was pretty much unusable as a design template. Quite apart from the basics of differ ...
... localised set of parameters that would better suit their needs. Up until the 2012 version of Revit MEP, the electrical template was very much a straight copy of the United State’s version of the same, and as such it was pretty much unusable as a design template. Quite apart from the basics of differ ...
NorMax® - Norelco Oy
... other circuit breakers (vacuum or SF6) can be fitted into the circuit breaker cubicle. Norelco uses reliable overcurrent, short circuit and earth fault current relay protection. Alternative relay according customer needs can be fitted. ...
... other circuit breakers (vacuum or SF6) can be fitted into the circuit breaker cubicle. Norelco uses reliable overcurrent, short circuit and earth fault current relay protection. Alternative relay according customer needs can be fitted. ...
WBO2 Meter Slim Manual Wide Band O2 Sensor display
... The sensor must be inserted in the exhaust system with its tip exposed to the exhaust gas flow. It must stay in an angle between 10 to 90 degrees to horizontal position, that is, with its end downward, in such a way that steam droplets cannot be accumulated between the body of the sensor and its cer ...
... The sensor must be inserted in the exhaust system with its tip exposed to the exhaust gas flow. It must stay in an angle between 10 to 90 degrees to horizontal position, that is, with its end downward, in such a way that steam droplets cannot be accumulated between the body of the sensor and its cer ...
Table of Contents 8.0
... The U.S. EPR FSAR includes the following COL Item in Section 8.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information describing the interface between the offsite transmission system, and the nuclear unit, including switchyard interconnections. ...
... The U.S. EPR FSAR includes the following COL Item in Section 8.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information describing the interface between the offsite transmission system, and the nuclear unit, including switchyard interconnections. ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.