• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Date_umn_0130M_15283 - University of Minnesota
Date_umn_0130M_15283 - University of Minnesota

... Figure 1.2: Input common mode range of NMOS differential pair ………………………2 Figure 1.3: Input common mode range of PMOS differential pair ……………………….3 Figure 1.4: Variation in the transconductance throughout the input common mode range …………………………………………………………………………3 Figure 2.1: DC level shifting using PM ...
PDF: 1.47MB
PDF: 1.47MB

... became possible to decrease the thermal resistance between junction and case Rth(j-c) substantially. And also it incorporates Mitsubishi's latest power chips CSTBT. So that despite its mounting area decreases to 75%, it realized higher current rating up to 50A. (2) Changing the method of short circu ...
Railcar Repairer Study Guide
Railcar Repairer Study Guide

... • Condition assessment ‐ what does the physical evidence mean?  • Linking the physical evidence to probable causes.  • Investigating the probable causes to determine if they were contributors to the  problem.  • Determining the root cause(s).  • Use of a Cause & Effect diagram (“fish bone” diagram)  ...
MAX3967A 270Mbps SFP LED Driver General Description Features
MAX3967A 270Mbps SFP LED Driver General Description Features

NCP1060 - High-Voltage Switcher for Low Power Offline SMPS
NCP1060 - High-Voltage Switcher for Low Power Offline SMPS

... Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected. 1. This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JES ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... Most important problem is due to the leakage inductance of the isolation transformer, which will result in high voltage spike during switching transition. And the current freewheeling due to the leakage inductance will increase conduction loss. A passive or an active clamp circuit can be used to sol ...
1 general
1 general

... dead-front covers shall be constructed of 16 gage steel and be secured using fast thread screws. Dead-front panels shall incorporate card slots (or similar feature) for each panel board to allow for individual branch breaker identification. Input/output gland plate (cable tray) shall be provided for ...
HMC574MS8 - University of Toronto Physics
HMC574MS8 - University of Toronto Physics

... be generated with proper RF circuit design techniques. Signal lines at the RF port should have 50 ohm impedance and the package ground leads and package bottom should be connected directly to the ground plane similar to that shown above. The evaluation circuit board shown above is available from Hit ...
™ ZXMS6004DT8 60V N-CHANNEL SELF PROTECTED ENHANCEMENT MODE
™ ZXMS6004DT8 60V N-CHANNEL SELF PROTECTED ENHANCEMENT MODE

... without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in acco ...
MapDCCD Version 2 Installation and setup guide
MapDCCD Version 2 Installation and setup guide

... and powered. This can potentially avoid creating a bigger issue that can take time, effort and cost to rectify. We recommend testing the following: ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... frequency at 60 Hz except during periods of major generation loss. During periods of generation loss, frequency will drop; however, ERCOT employees automatic firm load shedding schemes which unload the grid and allow generators to recover to normal frequency. All the transmission lines to the STPEGS ...
AC Sources - Operating 3.8.1  3.8  ELECTRICAL POWER SYSTEMS
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS

... ------------------------------NOTES------------------------------[ 1. This Surveillance shall not normally be performed in MODE 1 or 2. However, this Surveillance may be performed to reestablish OPERABILITY provided an assessment determines the safety of the plant is maintained or enhanced. Credit m ...
AC Sources - Operating 3.8.1  3.8  ELECTRICAL POWER SYSTEMS
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS

... ------------------------------NOTES------------------------------[ 1. This Surveillance shall not normally be performed in MODE 1 or 2. However, this Surveillance may be performed to reestablish OPERABILITY provided an assessment determines the safety of the plant is maintained or enhanced. Credit m ...
T N UC
T N UC

ZRC250
ZRC250

... The ZRC250 design provides a stable voltage without an external capacitor and is stable with capacitive loads. The ZRC250 is recommended for operation between 20μA and 5mA and so is ideally suited to low power and battery powered applications. ...
Disconnect Individually Mounted
Disconnect Individually Mounted

Singing Tesla Coil: Building a Musically
Singing Tesla Coil: Building a Musically

... be. Perhaps Edison’s greatest act of cruelty came in 1903, when he electrocuted Topsy the 6-ton circus elephant with 6000 volts AC in front of a group of 1500 spectators. [4] [5] (Warning: the videos are gruesome with regards to animal cruelty.) Ultimately, though, AC power won out. For one, lightbu ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
Liebert Series 610 UPS DISCONTINUED PRODUCT

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
the electromagnetic pulse and its effects
the electromagnetic pulse and its effects

... away from the burst point at the speed of light, as do all electromagnetic waves (§ 1.73), the radiation can be collected by metallic and other conductors at a distance, just as radio waves are picked up by antennas. The energy of the radiation can then be converted into strong electric currents and ...
evk-hades1210
evk-hades1210

... The isolated switched mode power supply is a regulated flyback DC-DC converter providing both isolated gate drivers with the positive and negative supply voltages required to drive the different types of FETs. The DC-DC converter function is fully integrated in CHT-HADES2P device. It provides as wel ...
Application Note No. 101
Application Note No. 101

Dynatel 965SLA OSP Basics - A collection of Bell System Practices
Dynatel 965SLA OSP Basics - A collection of Bell System Practices

InstallatIon and operatIon manual Solibro Solar Modules SL2 and SL2-F
InstallatIon and operatIon manual Solibro Solar Modules SL2 and SL2-F

... systems, on working with direct current and regulations of the responsible energy supply company regarding parallel operation of solar power plants. ...
ILD223T - PC Components Company
ILD223T - PC Components Company

... estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products ...
Mitigation of voltage sags/swells to enhance Power Quality of
Mitigation of voltage sags/swells to enhance Power Quality of

... momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage . This means that any differential voltages caused by transient disturbances in the ac feeder will be compensated by an equivalent voltage generate ...
< 1 ... 72 73 74 75 76 77 78 79 80 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report