SEL LED Remote (SRP/SRM) instruction sheet - 049-261
... 3. Do not let power supply cords touch hot surfaces. 4. Use caution when working with batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately. 5. Do not use this equipment for other than the i ...
... 3. Do not let power supply cords touch hot surfaces. 4. Use caution when working with batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately. 5. Do not use this equipment for other than the i ...
AN-3004 - Fairchild
... current, high voltage thyristors, while providing a guaranteed 7.5 kV dielectric withstand voltage between the line and the control circultry. An integrated, zero-crossing switch on the detector chip eliminates current surges and the resulting electromagnetic interference (EMI) and reliability probl ...
... current, high voltage thyristors, while providing a guaranteed 7.5 kV dielectric withstand voltage between the line and the control circultry. An integrated, zero-crossing switch on the detector chip eliminates current surges and the resulting electromagnetic interference (EMI) and reliability probl ...
DET Series EARTH GROUND ELECTRODE TESTERS USER GUIDE
... operation in situations which require it. The most appropriate output voltage should be selected by the operator based on local safety procedures. The procedure for changing the output voltage is as follows: ...
... operation in situations which require it. The most appropriate output voltage should be selected by the operator based on local safety procedures. The procedure for changing the output voltage is as follows: ...
NEMA # ICS-14 - Hubbell Industrial Controls
... 1. External control circuits that extend outside the fire pump room shall be arranged so that failure of any external circuit (open or short-circuit) shall not prevent operation of pump(s) from all other internal or external means (NFPA 20, 10.5.2.6; NFPA 70, 695.14). 2. Failure of external control ...
... 1. External control circuits that extend outside the fire pump room shall be arranged so that failure of any external circuit (open or short-circuit) shall not prevent operation of pump(s) from all other internal or external means (NFPA 20, 10.5.2.6; NFPA 70, 695.14). 2. Failure of external control ...
External SPDs - Surge Protective Devices
... Filter shall utilize a tuned, series-hybrid CLC filtering circuit coupled with metal oxide varistor array between each available mode. In addition to series inductor elements, the unit shall be mounted in series with the downstream load. Devices without series inductor elements designed to meet the ...
... Filter shall utilize a tuned, series-hybrid CLC filtering circuit coupled with metal oxide varistor array between each available mode. In addition to series inductor elements, the unit shall be mounted in series with the downstream load. Devices without series inductor elements designed to meet the ...
Train Current Detection Manual_J2C
... J2C Engineering Train Current Detection Manual This manual assumes that the user has a basic understanding of model railroading DCC and/or DC block wiring. The manual is broken down into several sections: Section 1 gives an overview of the pin out of the J2C detection circuit. Section 2 shows how t ...
... J2C Engineering Train Current Detection Manual This manual assumes that the user has a basic understanding of model railroading DCC and/or DC block wiring. The manual is broken down into several sections: Section 1 gives an overview of the pin out of the J2C detection circuit. Section 2 shows how t ...
Click here
... nothing is connected to the terminal that the switch is contacting in its normal position. (b) A single-pole, double-throw (SPDT) switch has three terminals. (c) A double-pole, single-throw (DPST) switch has two positions (off and on) and can control two separate circuits. (d) A double-pole, double- ...
... nothing is connected to the terminal that the switch is contacting in its normal position. (b) A single-pole, double-throw (SPDT) switch has three terminals. (c) A double-pole, single-throw (DPST) switch has two positions (off and on) and can control two separate circuits. (d) A double-pole, double- ...
LT1787/LT1787HV - Precision, High Side Current Sense Amplifiers
... Available in 8-Lead SO and MSOP Packages ...
... Available in 8-Lead SO and MSOP Packages ...
BD15HC0WEFJ
... (2) Connecting the power supply connector backward Connecting of the power supply in reverse polarity can damage the IC. Take precautions when connecting the power supply lines. An external direction diode can be added. (3) Power supply lines Design the PCB layout pattern to provide low impedance GN ...
... (2) Connecting the power supply connector backward Connecting of the power supply in reverse polarity can damage the IC. Take precautions when connecting the power supply lines. An external direction diode can be added. (3) Power supply lines Design the PCB layout pattern to provide low impedance GN ...
ALM-Gauge Manual
... wideband oxygen sensor and Bosch driver chip CJ125 to accurately measure the exhaust air/fuel ratio (AFR) of variant combustion engines. ALM-Gauge is a smaller size version of our previous ALM . It has the same accuracy and fast response characteristics like ALM, but much smaller size. The controlle ...
... wideband oxygen sensor and Bosch driver chip CJ125 to accurately measure the exhaust air/fuel ratio (AFR) of variant combustion engines. ALM-Gauge is a smaller size version of our previous ALM . It has the same accuracy and fast response characteristics like ALM, but much smaller size. The controlle ...
BD9123MUV
... 6. Consideration on Permissible Dissipation and Heat Generation As this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including lowe ...
... 6. Consideration on Permissible Dissipation and Heat Generation As this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including lowe ...
Accurate single-end fault location and line-length estimation
... Accurate fault locating is critical for the reliable operation of power systems. Identifying permanent faults is important for power system restoration; however, locating temporary faults with successful autoreclosing may not have a similar level of urgency. Traveling-wave-based fault location (TWFL ...
... Accurate fault locating is critical for the reliable operation of power systems. Identifying permanent faults is important for power system restoration; however, locating temporary faults with successful autoreclosing may not have a similar level of urgency. Traveling-wave-based fault location (TWFL ...
OWNER`S MANUAL 193111-079
... In addition to the usual function of protecting personnel against the hazard of electrical shock due to fault in the equipment, grounding serves to discharge the static electrical charges which tend to build up on the surfaces of equipment. These static charges can cause painful shock to personnel, ...
... In addition to the usual function of protecting personnel against the hazard of electrical shock due to fault in the equipment, grounding serves to discharge the static electrical charges which tend to build up on the surfaces of equipment. These static charges can cause painful shock to personnel, ...
BD00HC0WEFJ
... (2) Connecting the power supply connector backward Connecting of the power supply in reverse polarity can damage the IC. Take precautions when connecting the power supply lines. An external direction diode can be added. (3) Power supply lines Design the PCB layout pattern to provide low impedance GN ...
... (2) Connecting the power supply connector backward Connecting of the power supply in reverse polarity can damage the IC. Take precautions when connecting the power supply lines. An external direction diode can be added. (3) Power supply lines Design the PCB layout pattern to provide low impedance GN ...
the tetrode boards
... • Loading too light, or too heavy • Too much RF drive • Loss or major change in anode, screen or control grid voltage • RF and DC arcs, flashovers and other ‘glitches’ • Blower failure, resulting in overheating of the tube(s). All of these faults will result in too much screen current, either positi ...
... • Loading too light, or too heavy • Too much RF drive • Loss or major change in anode, screen or control grid voltage • RF and DC arcs, flashovers and other ‘glitches’ • Blower failure, resulting in overheating of the tube(s). All of these faults will result in too much screen current, either positi ...
- Integrated
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
Introduction - Electrical and Computer Engineering
... Time-varying currents and voltages resulting from sudden application of sources, usually due to switching ...
... Time-varying currents and voltages resulting from sudden application of sources, usually due to switching ...
Document
... 67P element is advocated to detect power flow from the low side of Transformer I toward the high side, which it states can be caused by high-side faults under the switching conditions described previously. Reference [1] also states that reverse power flow can occur during times when Breaker F is ope ...
... 67P element is advocated to detect power flow from the low side of Transformer I toward the high side, which it states can be caused by high-side faults under the switching conditions described previously. Reference [1] also states that reverse power flow can occur during times when Breaker F is ope ...
Liebert Series 610 UPS Installation Manual - 300-450kVA, 60Hz, Three Phase Multi-Module
... Slots at the base of the modules and battery cabinets are intended for forklift use. Base slots will support the unit only if the forks are completely beneath the unit. System Control Cabinets (SCCs) have holes intended for rigging bars or chains. Prevent chains or cables from contacting cabinet by ...
... Slots at the base of the modules and battery cabinets are intended for forklift use. Base slots will support the unit only if the forks are completely beneath the unit. System Control Cabinets (SCCs) have holes intended for rigging bars or chains. Prevent chains or cables from contacting cabinet by ...
DISTRIBUTION TRANSFORMERS AND MAINTENANCE KALOGERAKIS STYLIANOS
... varied types of transformers used on the electricity supply network. There are around 500 000 distribution transformers on public electricity supply system operated by the Regional Electricity Companies and a similar number installed in industrial installations. They range in size from about 15 kVA, ...
... varied types of transformers used on the electricity supply network. There are around 500 000 distribution transformers on public electricity supply system operated by the Regional Electricity Companies and a similar number installed in industrial installations. They range in size from about 15 kVA, ...
... of power electronics based loads and microprocessor based controlled loads. On one hand these devices introduce power quality problem and on other hand these mal-operate due to the induced power quality problems. PQ disturbances cover a broad frequency range with significantly different magnitude va ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.