• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Training
Training

TENMA VARIABLE OUTPUT ISOLATION TRANSFORMER SAFETY
TENMA VARIABLE OUTPUT ISOLATION TRANSFORMER SAFETY

... TENMA VARIABLE OUTPUT ISOLATION TRANSFORMER SAFETY: AC power supplies are sources of high voltage. Improper or careless use could result in fatal electrical shock. Observe common sense safety precautions when using this and other electronic devices. Turn the INPUT POWER switch OFF and set the OUTPUT ...
gc-10 : parallel path isolator
gc-10 : parallel path isolator

... the cable ground allows a groundconductor monitor to ignore the parallel path and monitor only the cable ground conductor. • two or more pieces of trailing-cable-fed equipment are fed from the same power center. Trailing cable ground conductors are parallelled if equipment frames touch or are conne ...
electrical transients:keeping the enemy out of your facility
electrical transients:keeping the enemy out of your facility

unparalleled protection - I-Gard
unparalleled protection - I-Gard

... the loss of low-voltage power can be especially disruptive and can cause a complete upset. This scenario can cause a plant to close, create personnel and equipment safety problems, have an adverse environmental impact, and can result in substantial economic losses. As such, the need for a safe, reli ...
Dia 1 - XAMK Moodle
Dia 1 - XAMK Moodle

... Over current protective devices: *Miniature circuit breakers * Fuses *Residual current protective devices ...
city of surrey electrical inspection report for primary unit substations
city of surrey electrical inspection report for primary unit substations

... A Field Review report from the design engineer is to be submitted indicating the installation has been inspected, all test reports have been reviewed, and the installation is now ready to energize Supplementary bonding requirements for high voltage room (pull pit cover; doors; duct work; steel cladd ...
Basic Terms Note sheet
Basic Terms Note sheet

UcD400
UcD400

... Although Hypex UcD modules are based on very efficient Class-D technology, additional cooling is a must. Mounting the modules on a sheet of aluminium will provide enough cooling for use under normal conditions. When the module is used in a closed case, provide enough airflow by means of ventilation ...
3A1978
3A1978

... directly into the cable of the system/equipment to be protected using the connectors at both ends. The overvoltage protection circuit has a valve characteristic, i.e., the BSPD5BNCSI is installed so that the output indicated on the equipment label ( protected) faces towards the equipment to be prot ...
EE 201 ELECTRIC CIRCUITS
EE 201 ELECTRIC CIRCUITS

... Find the equivalent resistance ...
Glossary of Terms - Lyncole Grounding
Glossary of Terms - Lyncole Grounding

... International Association of Electrical Inspectors (IAEI) - A professional society of electrical inspectors. Joule - A unit of electrical, mechanical and thermal energy. One joule is equal to the amount of energy to the work done when a current of one ampere is passed through a resistance of one ohm ...
Power-system protection
Power-system protection

WEEK TWO LISBURN 2391
WEEK TWO LISBURN 2391

... the Week One workbook. It is, however, important to ensure that these other aspects of protection are fully appraised in our inspection. We continue now to look at one very important method of protection against indirect shock. EBADOS is by far the most common method employed to provide such protect ...
Theories In Electronics Vocabulary Teacher`s Guide
Theories In Electronics Vocabulary Teacher`s Guide

... Resistance – The ability to oppose an electrical current. Conductor – A material that has a loose grip on its electrons so the electrical current can pass through it. Insulator – A material that maintains a tight grip on its electrons so that an electrical current cannot flow through it. Fuse – A ci ...
Operational Manual For A Voltage Stabilizing Ground Reference
Operational Manual For A Voltage Stabilizing Ground Reference

... To understand the operation of the Voltage Stabilizing Ground Reference the following explanation is necessary: Ohms Law for AC circuits is Voltage equals Current multiplied by Ohms of Impedance, and as the leading event the voltage change when detected offers the fastest reaction time. Phaseback op ...
Lecture 13
Lecture 13

... are designed to sense the development of a dangerous situation and operate to cut off the electrical supply to that circuit before the danger reaches an unacceptable level. ...
INTRODUCTION TO T&T WIRING CODE
INTRODUCTION TO T&T WIRING CODE

... system is subjected only to that potential difference. • Facilitates the operation of over current devices such as fuses, circuit breakers or relays under ground fault conditions. ...
Electrical System
Electrical System

... ω is the angular frequency (unit: radians per second) – The angular frequency is related to the physical frequency, f, which represents the number of oscillations per second (unit = hertz), by the equation ...
Notes on Wiring the G320 and Mach 3
Notes on Wiring the G320 and Mach 3

... apart are at the same potential. (ground is not Ground!) The more current there is between the systems and the higher the frequencies the more pronounced the difference. For logic level circuits a volt or two of noise can produce unwanted effects. Two opto isolated systems must have separate power ...
Electrical Grounds
Electrical Grounds

... – Limit the voltage upon the circuit which might otherwise occur through exposure to lightning or other voltages higher than that for which the circuit is designed. – Another purpose in grounding one of the wires of the system is to limit the maximum voltage to ground under normal operating conditio ...
Electrical Engineering for Physicists
Electrical Engineering for Physicists

...  Vrms  ...
Electrical Flow Rate
Electrical Flow Rate

... Electrical Rate: Page 82 Flow of electrons! ...
What causes the electrical faults or voltage dips? These electrical
What causes the electrical faults or voltage dips? These electrical

... These electrical faults arise because the smoke and other matter from the fire provide a conductive path, which in layman’s terms results in a “short circuit”. Smoke containing carbon and ash from the bushfire rises and can cause electricity to ‘arc’, or ‘jump’, from one line to another creating a p ...
ELECTRICAL SAFETY DEVICES
ELECTRICAL SAFETY DEVICES

... this and cuts off the power before he/she can get injured. GFCIs are generally installed where electrical circuits may accidentally come into contact with water. They are most often found in kitchens, bath and laundry rooms, or even out-of-doors or in the garage where electric power tools might be u ...
< 1 ... 578 579 580 581 582 583 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report