InstallatIon and operatIon manual Solibro Solar Modules SL2 and SL2-F
... ¼¼ Note the wiring and dimensioning of the system. ¼¼ The observance of all necessary safety regulations when laying out and installing the system are the responsibility of the installer of the system. This manual does not form a legal responsibility on the part of Solibro. Solibro only accepts lia ...
... ¼¼ Note the wiring and dimensioning of the system. ¼¼ The observance of all necessary safety regulations when laying out and installing the system are the responsibility of the installer of the system. This manual does not form a legal responsibility on the part of Solibro. Solibro only accepts lia ...
gei50261 - GE Grid Solutions
... The principal application of the NBV11A relay is to protect three-phase motors from the damage that may be caused by single-phase operation. When one fuse blows in a three-phase supply to a group of motors, these motors will continue to run on single-phase power. At this time, the voltage unbalance ...
... The principal application of the NBV11A relay is to protect three-phase motors from the damage that may be caused by single-phase operation. When one fuse blows in a three-phase supply to a group of motors, these motors will continue to run on single-phase power. At this time, the voltage unbalance ...
ADM1172 数据手册DataSheet 下载
... Power-Fail Comparator Output. Digital output from the power-fail comparator. Input Pin. The ON (ON-CLR) pin is an input to a comparator that has a low-to-high threshold of 1.3 V with 80 mV hysteresis and a glitch filter. The ADM1172 is reset when the ON (ON-CLR) pin is low. When the ON (ON-Error!) p ...
... Power-Fail Comparator Output. Digital output from the power-fail comparator. Input Pin. The ON (ON-CLR) pin is an input to a comparator that has a low-to-high threshold of 1.3 V with 80 mV hysteresis and a glitch filter. The ADM1172 is reset when the ON (ON-CLR) pin is low. When the ON (ON-Error!) p ...
P82623
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
Code of Practice for Personnel Electrical Safety for
... ‘Power line’ or ‘line’ means any aerial conductor or conductors with associated supports, insulators and other apparatus erected, or in the course of erection, to convey electrical energy. ‘Procedure’ means the documentation of a systematic series of actions (or activities) directed to achieve a des ...
... ‘Power line’ or ‘line’ means any aerial conductor or conductors with associated supports, insulators and other apparatus erected, or in the course of erection, to convey electrical energy. ‘Procedure’ means the documentation of a systematic series of actions (or activities) directed to achieve a des ...
Multi-Output Power Supply with VCOM Amplifier MAX17114 General Description
... charge pump, an operational amplifier, a high-accuracy, high-voltage gamma reference, and a high-voltage switch control block. The MAX17114 can operate from input voltages from 8V to 16.5V and is optimized for an LCD TV panel running directly from 12V supplies. The step-up and step-down switching re ...
... charge pump, an operational amplifier, a high-accuracy, high-voltage gamma reference, and a high-voltage switch control block. The MAX17114 can operate from input voltages from 8V to 16.5V and is optimized for an LCD TV panel running directly from 12V supplies. The step-up and step-down switching re ...
Residual Current Protective Devices / Arc Fault Detection Devices SENTRON
... Frequency converters, medical devices and UPS systems are seeing increasing use in industry. Smooth DC residual currents or currents with low residual ripple may occur in the event of faults on these devices. Type A residual current protective devices are unable to detect these smooth DC residual cu ...
... Frequency converters, medical devices and UPS systems are seeing increasing use in industry. Smooth DC residual currents or currents with low residual ripple may occur in the event of faults on these devices. Type A residual current protective devices are unable to detect these smooth DC residual cu ...
Mapping Document
... meeting all of the requirements of R7.1, R7.2, R7.3, and R7.4 recorded no further than two Substations away, then for each Substation having a total of seven or more transmission lines connected at 200 kV or above, the Transmission Owner shall record (or have a process in place to derive) the follow ...
... meeting all of the requirements of R7.1, R7.2, R7.3, and R7.4 recorded no further than two Substations away, then for each Substation having a total of seven or more transmission lines connected at 200 kV or above, the Transmission Owner shall record (or have a process in place to derive) the follow ...
Distance Protection for Half Wavelength Transmission Lines
... over long distances is very important in countries with continental dimensions. Brazil has great energy potential in the north region in the Amazon rainforest, which also encompasses neighboring countries, while large consumer centers are in the southeastern region of Brazil. Nowadays, these huge bu ...
... over long distances is very important in countries with continental dimensions. Brazil has great energy potential in the north region in the Amazon rainforest, which also encompasses neighboring countries, while large consumer centers are in the southeastern region of Brazil. Nowadays, these huge bu ...
AN4026
... Voltage on the L6563H VFF pin (#5) has the same value as the peak value of the voltage on the MULT pin (#3) and it is generated by the RC network (R15 + R26, C12) connected to VFF, completing an internal peak-holding circuit. This signal is necessary to derive information from the RMS input voltage ...
... Voltage on the L6563H VFF pin (#5) has the same value as the peak value of the voltage on the MULT pin (#3) and it is generated by the RC network (R15 + R26, C12) connected to VFF, completing an internal peak-holding circuit. This signal is necessary to derive information from the RMS input voltage ...
Optocoupler, Phototransistor Output, with Base Connection
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
Data Sheet V2.0 2014-01-20 CoolSET™ F3R80 ICE3AR1080VJZ
... All values which are used in the functional description are typical values. For calculating the worst cases the min/max values which can be found in section 4 Electrical Characteristics have to be considered. ...
... All values which are used in the functional description are typical values. For calculating the worst cases the min/max values which can be found in section 4 Electrical Characteristics have to be considered. ...
Conductivity Monitoring LRGT 16-1 LRGT 16-2 LRGT 17-1
... electrodes, the boiler wall, the smoke tubes and any other metal fittings as well as the low water level (LW). Note that the measuring surface(s) must be constantly in contact with the water. ...
... electrodes, the boiler wall, the smoke tubes and any other metal fittings as well as the low water level (LW). Note that the measuring surface(s) must be constantly in contact with the water. ...
Dual High-Voltage Power Supply for use On Board a CubeSat
... look towards interplanetary travel. These small satellites could provide a cost effective means of exploring the galaxy, using off the shelf components and piggy-backing on other launch vehicles with more expensive payloads. However, CubeSats are traditionally launched into Low Earth Orbit (LEO), an ...
... look towards interplanetary travel. These small satellites could provide a cost effective means of exploring the galaxy, using off the shelf components and piggy-backing on other launch vehicles with more expensive payloads. However, CubeSats are traditionally launched into Low Earth Orbit (LEO), an ...
Technical guide Protection criteria for medium voltage
... and additional protections can also be provided exploiting the potential logics and protection functions available in digital relays. The “from the theoretical point of view” statement, is to underline that, from the theoretical point of view, it is possible to identify and therefore eliminate just ...
... and additional protections can also be provided exploiting the potential logics and protection functions available in digital relays. The “from the theoretical point of view” statement, is to underline that, from the theoretical point of view, it is possible to identify and therefore eliminate just ...
Vacuum Circuit Breaker Technology
... C37.04-1999, the rated TRV is represented by a 1-cosine wave, while on the other hand, in IEC 62271-100, 2003 the TRV is represented by an exponential-cosine wave as shown in Table 2 and Fig. 9. These ratings are for shortcircuit tests, duty 4 and duty 5 in IEEE C37.09 and for terminal fault test, d ...
... C37.04-1999, the rated TRV is represented by a 1-cosine wave, while on the other hand, in IEC 62271-100, 2003 the TRV is represented by an exponential-cosine wave as shown in Table 2 and Fig. 9. These ratings are for shortcircuit tests, duty 4 and duty 5 in IEEE C37.09 and for terminal fault test, d ...
appendix d: suggestion form, qa-90
... METRON warrants that the QA-90 Electrical Safety Analyzer will substantially conform to published specifications and to the documentation, provided that it is used for the purpose for which it was designed. METRON will, for a period of twelve (12) months from date of purchase, replace or repair any ...
... METRON warrants that the QA-90 Electrical Safety Analyzer will substantially conform to published specifications and to the documentation, provided that it is used for the purpose for which it was designed. METRON will, for a period of twelve (12) months from date of purchase, replace or repair any ...
MMFE-8-Specification
... L1DDC I/O The I/O from/to the L1DDC are via a 36 pin MiniSAS connector. This is shown on Sheet 3 of the schematic. The signals are all “VMM LVDS”, called custom LVDS in the VMM specification document. The data and clocks correspond to three e-links. E-link 1 is actually two data e-links but with onl ...
... L1DDC I/O The I/O from/to the L1DDC are via a 36 pin MiniSAS connector. This is shown on Sheet 3 of the schematic. The signals are all “VMM LVDS”, called custom LVDS in the VMM specification document. The data and clocks correspond to three e-links. E-link 1 is actually two data e-links but with onl ...
4N25 - Vishay
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.