• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Local Technical - Florida Building Code
Local Technical - Florida Building Code

... (A) General. Metal raceways, cable trays, cable armor, cable sheath, enclosures, frames, fittings, and other metal non-current-carrying parts that are to serve as equipment grounding conductors, with or without the use of supplementary equipment grounding conductors, shall be bonded where necessary ...
article - EE Times
article - EE Times

Ground Resistance Clamp-On Tester - Cole
Ground Resistance Clamp-On Tester - Cole

DSTATCOM supported induction generator for improving power
DSTATCOM supported induction generator for improving power

... for improving current induced power quality issues and voltage regulation of three-phase selfexcited induction generator (SEIG). The use of SMC for regulating the DC link voltage of DSTATCOM offers various advantages such as reduction in number of sensors for estimating reference currents and the st ...
Capacitor Self
Capacitor Self

... CABLE! ...
#2095
#2095

... * N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems. ** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. ...
DN351 - Versatile Micropower Voltage Reference Provides Resistor Programmable Output from 0.4V to 18V
DN351 - Versatile Micropower Voltage Reference Provides Resistor Programmable Output from 0.4V to 18V

... reference voltage above 0.4V with the added feedback components. This configuration provides programmable reference voltages anywhere up to 0.35V below the supply potential used, the dropout voltage. Resistor RG is chosen in the range from 10k to 100k to set the quiescent loading of the reference, t ...
SET 1 - contentcarry
SET 1 - contentcarry

... Q.30:- “In all cases of electromagnetic induction, an induced voltage will cause a current to flow in a closed circuit in such a direction that the magnetic field which is caused by that current will oppose the change that produces the current” is the original statement of (a) (b) (c) (d) ...
bolt heating equipment
bolt heating equipment

... the bolts and screwing down the nuts while in this hot condition. The joint flange bolt heating unit is used for heating the bolts to allow the subsequent screwing down of the nuts to give the required preloading. The heating effect is generated by passing a high electric current through the bolt to ...
Chapter 6: Analog Electrical Devices
Chapter 6: Analog Electrical Devices

... The ground at the feeder box may not be at the earth ground potential due to the voltages that have been induced into the down stream ground conductor. – The difference between the two ground point voltages is called common-mode voltage. ...
Low saturation voltage type 3-pin regulator
Low saturation voltage type 3-pin regulator

... This protection circuit limits the current in the shape of a ’7’. This circuit is designed with a high margin, so that that current is restricted and latching is prevented, even if a high-capacitance capacitator causes a large amount of current to temporary flow through the IC. However, these protec ...
PDF
PDF

... Bushing terminals will be threaded stud type, 1 1/4-12 UNF2A, Current interruption will occur in vacuum interrupters, one interrupter per phase. It will be possible to replace one or all bushings without any re-alignment or adjustment of the vacuum interrupters or operating mechanism. The interrupti ...
Operating instructions ATEX - i-for-T
Operating instructions ATEX - i-for-T

... ►► Read them before use to familiarise yourself with operating conditions, UK installation and operation. ►► Follow the safety instructions. The operating instructions are intended for authorised persons according to the EMC and low voltage directives. 2.2  Other important notes • The unit must onl ...
Lab 2 - Classes - Oregon State University
Lab 2 - Classes - Oregon State University

... relative to node E. Also measure the current through the ladder. (Remember to break the circuit loop and insert the ammeter to measure current – as we saw in the previous lab, unlike a voltmeter, an ammeter only measures current passing through it.) Are the voltage and current values close to what w ...
Distribution systems
Distribution systems

SBF5089Z
SBF5089Z

- PAT tel doo
- PAT tel doo

... for individual power supply for 3 RRH, especially when using circuit breakers. The PTTA box medium has optional a second power entry cable gland. This is useful when a bigger cross section is needed in case of long distances. The cross section can be increased up to 32 mm2 (2 x 16 mm2). Further, the ...
PQ Overview – Practical Aspect
PQ Overview – Practical Aspect

TRANSFORMER TYPES Potential Transformers
TRANSFORMER TYPES Potential Transformers

... various voltage, frequency and physical size ranges. We have broken them up into several different groupings: low voltage, which are system voltages under 15kV; high frequency, operating frequency over 1kHz; and size ranges from board mount parts up to current transformers with window sizes of 254mm ...
DC POWER SUPPLY BLOCK DIAGRAM OF POWER SUPPLY
DC POWER SUPPLY BLOCK DIAGRAM OF POWER SUPPLY

... A resistor constructed so that its resistance value may be changed without interrupting the circuit to which it is connected. Also known as variable resistor. ...
AN-996 Using the Fairchild FST Bus Switch AN-
AN-996 Using the Fairchild FST Bus Switch AN-

... To preserve the low power design of the switch and to provide optimal operation, select a low current turn on diode with a forward turn on voltage (Vf) of at least 0.7V. A resistor (R) is added from the VCC pin to GND to provide forward turn on current (If) for the diode. This is necessary to help t ...
Quick Start Guide
Quick Start Guide

... in the vehicle, or even from additional electrical equipment connected to the vehicle’s electrical power system. Without treatment, sharp spikes are a potential threat to K530 Series router as well as other electrical equipment on the vehicle. ...
Kirchhoffs_Laws
Kirchhoffs_Laws

... Layout the schematic shown below using these components: Vdc, R_var, R (twice), and gnd_earth. ...
Experiment FT2: Measurement of Inductance and Mutual Inductance
Experiment FT2: Measurement of Inductance and Mutual Inductance

... If the secondary circuit is closed, for example, by connecting a resistor to the terminals, a current I2 will start to flow. By this electromagnetic induction, the electrical energy is transferred from the primary winding to the secondary winding by means of magnetic field coupling. Assuming that th ...
A 100 Watt Audio Amplifier Employing The LM3876
A 100 Watt Audio Amplifier Employing The LM3876

... and C6 form the time constant for the IC's power-on mute function, which suppresses power-on pops by disabling the internal bias supplies until the power supply voltages have fully stabilized. C1, C2, C5, and C7 provide additional power supply filtering and should be mounted directly onto U1's power ...
< 1 ... 448 449 450 451 452 453 454 455 456 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report