• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Product Brief TLE 4309 G Power LED Driver Adjustable Constant Current Source
Product Brief TLE 4309 G Power LED Driver Adjustable Constant Current Source

Electrical Engineering Semester - VI
Electrical Engineering Semester - VI

... test , Core insulation voltage test, Measurement of impedance ,Testing of auxiliaries and safety device , Oil testing , Classification of testing methods , Testing of bushing. DC and AC Resistance measurement, Temp. Rise test, Short circuit test, Dielectric test, Partial discharge, Insulation resist ...
ADD CURRENT LIMIT TO THE BUF634
ADD CURRENT LIMIT TO THE BUF634

... Modern buffer amplifiers, such as the BUF634, are often used with op amps to drive high-current demand loads such as cables or electro-mechanical devices. BUF634 features internal overload protection to prevent its destruction under fault conditions. Internal current limit protects circuitry and wir ...
AVR-P20 User Manual
AVR-P20 User Manual

... •RS232 Tx, Rx interface with MAX232 IC on socket •10MHz crystal on socket (user can replace with any value) •reset IC ZM33064 •reset button •general purpose push button •status LED connected to PB7 via removable jumper •DIL20 microcontroller socket •selectable +3.3V / +5V power supply voltage regula ...
ECE 310 - University of Illinois at Urbana–Champaign
ECE 310 - University of Illinois at Urbana–Champaign

... The most common type of fault on a three phase system by far is the single line-to-ground (SLG), followed by the line-to-line faults (LL), double lineto-ground (DLG) faults, and balanced three phase faults ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

Shipboard Electrical Equipment
Shipboard Electrical Equipment

... different ratings. The rating of an MG set can be less than 1 kW or as large as 300 kW. MGs can also be used to provide electrical isolation. Isolation is required when certain loads cause distortion of the power and adversely affect the operation of other equipment. The MG set (fig. 12-5) is genera ...
technical data - shaft grounding
technical data - shaft grounding

... A largely unknown segment is shaft grounding in ships. Different metals are used for the construction of ships The hull is made by steel, the propeller made of brass or bronze. The shaft is grounded to avoid electrochemical phenomenon, fed by the conductive salt water. The propeller and the shaft ar ...
GNS RF2422
GNS RF2422

File - new open world
File - new open world

... accessory of an oil filled type transformer which is attached into the oil conservator tank. • It protect moisture entering the conservator tank. • In the refrigeration breather system, an air dryer is fitted to the conservator vessel. ...
ECE4762007_Lect19
ECE4762007_Lect19

... The most common type of fault on a three phase system by far is the single line-to-ground (SLG), followed by the line-to-line faults (LL), double lineto-ground (DLG) faults, and balanced three phase faults ...
Series Vs. Parallel
Series Vs. Parallel

... OF COURSE NOT!!!! Homes are not, and should not, be wired that way. But there ARE electrical hookups that work so all electrical devices on the circuit are either turned ON or turned OFF. This kind of electrical circuit is called a SERIES CIRCUIT. There are 2 important things to remember about a Ser ...
Section P Index
Section P Index

... WIRE (PLUGS AND RECEPTACLES) The term “wire” as used in designating plugs and receptacles indicates the number of either normally current-carrying or equipment grounding connected conductors. ...
Single Circuit and Series Wired Applications
Single Circuit and Series Wired Applications

... •Lighting •Computers and Peripherals •Industrial Equipment •Any Individual Piece of Equipment or Circuit Electrical Environment Because these circuits are connected to high value equipment they are generally somewhat protected and have lower voltages and currents. But as more intelligence is put int ...
Lecture04 - madalina
Lecture04 - madalina

... Due to a different number of factors (technological factors, reduced costs etc) the real values of the parameters are near to the rated (target) values. By the selective measurements, the manufacturers offers only those components which have the parameters in the some specific limits around the rate ...
Single-Line Diagrams
Single-Line Diagrams

Critical Points of Simplified Model for Ferroresonance Phenomenon in Single Phase Power Transformers
Critical Points of Simplified Model for Ferroresonance Phenomenon in Single Phase Power Transformers

... reactance equals the inductive reactance at the frequency at which the circuit is driven. Iron-core inductors have a nonlinear characteristic and have a range of inductance values. Therefore, there may not be a case where the inductive reactance is equal to the capacitive reactance, but yet very hig ...
Riotech Instruments Ltd LLP
Riotech Instruments Ltd LLP

... The VTU1X tracks the speed of the monitored equipment (when a tachometer is used) and generates an output based on that speed and the vibrations measured by an accelerometer. It takes a minimum of four rotations to acquire enough data to generate a stable output. Therefore the update rate is ¼ the R ...
Lab 2. Capacitance, Capacitive Reactance, and Capacitive
Lab 2. Capacitance, Capacitive Reactance, and Capacitive

... Connecting capacitors in parallel is effectively the same as making a single capacitor’s plates larger, and therefore able to hold more charge for a given applied voltage. This simple view is borne out if one analyzes the flow of charge through a parallel array of capacitors connected to a voltage s ...
Guidelines for the Design, Installation, Operation
Guidelines for the Design, Installation, Operation

Electrical Safety Policy Contents - Freeport
Electrical Safety Policy Contents - Freeport

... electrowinning/electrorefining equipment. Standing in puddles of electrolyte and touching energized surfaces can create a shock hazard. Build-up of electrolyte and sulfate around and below tankhouse cells can create unexpected paths for stray currents and must be prevented by timely repairs of leaks ...
Reactive Power Compensation in Transmission Lines Using Static
Reactive Power Compensation in Transmission Lines Using Static

... The study of shunt connected Flexible AC Transmission System (FACTS) device is a connected field with the Reactive Power Compensation and the better mitigation of transmission in Power Systems. The FACTS technology based on Power Electronics devices is used to enhance existing transmission capabilit ...
Evaluating Microstrip with Time Domain Reflectometry
Evaluating Microstrip with Time Domain Reflectometry

... The arrangement shown in Figure 7A has been used to investigate the behavior of two different line shapes. For one line, corners are sharp. This causes the width of the line to be larger at corners than elsewhere. Figure 7B shows that a –7.5% reflection occurs at points 2 and 3 due to the lowered ch ...
Top 10 Aircraft Wiring Mistakes
Top 10 Aircraft Wiring Mistakes

...  http://www.terminaltown.com/Pages/Page2.html ...
R R V V = R R RR VV = = V = V R R R R V V = 5.45.7 1250 750
R R V V = R R RR VV = = V = V R R R R V V = 5.45.7 1250 750

... A series connection of two or more resistors forms a voltage divider. The voltage supplied to the series connection is divided into voltages in the same ratio as the resistances of the components in the unloaded voltage divider. If the voltage divider is loaded, the resistance of the load must be ta ...
< 1 ... 351 352 353 354 355 356 357 358 359 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.