• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
wrong cable size? how did you determine the maximum demand?
wrong cable size? how did you determine the maximum demand?

Safety Induction to the Lift & Escalator Industry
Safety Induction to the Lift & Escalator Industry

...  Familiarise yourself with the safe system of work for installing and maintaining this type of equipment,  The manufacturer should provide instructions detailing how to safely install and maintain the equipment.  Beware, on some lifts the car roof cannot support the weight of a person so manufact ...
WIPO IPC: Internet Publication
WIPO IPC: Internet Publication

... the whole mechanical aspect of the apparatus or devices, whereas the electrical aspect, as such, is covered by subclass H05B;  In the case of lighting, this mechanical aspect should be taken to cover the material arrangement of the various electric elements, i.e., their geometrical or physical posi ...
Mains Electricity - We can`t sign you in
Mains Electricity - We can`t sign you in

... because it is a good conductor of electricity. Each wire is made of thin strands of copper to keep the cable flexible. Each wire is encased in plastic to stop the wires touching and causing a short circuit. Plastic is used as it is a good insulator as well as being tough and flexible. The whole cabl ...
C22 Preamplifier Complete User Manual
C22 Preamplifier Complete User Manual

... 3. Connect the power transformer 280-300V AC, 12-15V AC, and 6.3V AC to the board, without plugging the vacuum tubes. 4. Measure the AC voltages at the connectors to see whether the voltages are maintained that are 280V AC, 15V AC and 6.3V AC. 5. If the voltages are correct, plug in the tubes and tu ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

24-Transistor
24-Transistor

True RMS - Test Equipment Depot
True RMS - Test Equipment Depot

Lockheed Martin Challenge - Senior Design
Lockheed Martin Challenge - Senior Design

... Video System Antennae • Weight, simplicity, range, and frequency (2.4GHz) were the driving factors when selecting an antenna for both the transmitter and the receiver • Directional antenna on-board is preferred to omnidirectional, but is not practical – Larger size/weight than omni-directional – In ...
Interphase Power Controllers - IEEE Canadian Review / La revue
Interphase Power Controllers - IEEE Canadian Review / La revue

... ne of the main reasons for developing the Interphase Power Controller (IPC) technology was to create new power flow controllers that would overcome the limitations on system operation caused by high short-circuit levels. In fact, excessive short-circuit levels constitute a widespread problem that ha ...
MV Switchgear 25kVMetal-Clad Outdoor
MV Switchgear 25kVMetal-Clad Outdoor

... specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by the local utility’s specifications. It shall also conform to the general electrical and construction design of the switchgear specified above. ...
3CX3000A7- - - 7.12to 7.87 VAC
3CX3000A7- - - 7.12to 7.87 VAC

... never exceed 10% of the forward or incident power. It is the user's responsibility to choose a cable type that will handle the expected opernting power from the amplifier at the frequency of operntion. A minimum choice of coax would be RG8 or RG213 type. GROUND LUG: This lug is provided for an earth ...
After you`ve designed the world`s best servo…
After you`ve designed the world`s best servo…

... Ripple refers to the power supply's instantaneous output voltage variations, Figure 8, which occur at twice the power supply frequency. While output droop may be measured on an ordinary DC-reading voltmeter, ripple viewing requires an oscilloscope. Ripple creates problems that are less readily diagn ...
STI13005-1
STI13005-1

... No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, ...
Here
Here

... uncertainty conditions. Reference [3] research work has been done in GSM based fully automated system in power transformer. To operate a power distribution system with a transformer out of service is always very difficult. The impact of a transformer fault is more serious than a transmission line ou ...
401300_CFR_Layout 1 - Pactrol Controls Ltd
401300_CFR_Layout 1 - Pactrol Controls Ltd

1. Introduction
1. Introduction

... be the same as on substation 138kV bus j, except for possible zero-sequence component blocking and positive/negative-phase shifts. The significance of the above paragraph is that for transmission faults, one monitor at either the substation 138kV bus or at the substation 12.47kV bus is adequate to p ...
Amateur Radio Technician Class Element 2 Course Presentation
Amateur Radio Technician Class Element 2 Course Presentation

...  The winding axes of solenoid inductors should be placed at right angles to minimize their mutual inductance. (G6A10) ...
Microcomputer Datasheets Important Notices TLCS
Microcomputer Datasheets Important Notices TLCS

... With regard to the Toshiba 8-bit microcontrollers listed above, the following corrections should be made to the technical datasheets regarding the electrical characteristics of the power-on reset circuit. If you have any questions or require any further information, please contact your local Toshiba ...
MV Switchgear 5kVMetal-Clad Indoor
MV Switchgear 5kVMetal-Clad Indoor

... covered by metal shutters when the circuit breaker is withdrawn from the connected position to the test or disconnected position or removed from the circuit breaker compartment. Extend a ground bus into the circuit breaker compartment to automatically ground the breaker frame with high current sprin ...
Lab 9 Handout
Lab 9 Handout

... in the prelab. The values from the prelab are the same for this circuit. You will not put a resistor in this circuit; the series resistance of the inductor will act as the resistive component (R = 0.6 Ohms). The measurements in this circuit will be different from the first two. You will be measuring ...
Sitras SFC plus - center
Sitras SFC plus - center

... It essentially consists of only one converter that directly couples the two networks. The three-phase AC voltage is directly converted into a single-phase AC voltage with different frequency. Due to the multilevel technology no traction transformer is needed to feed the overhead contact line. ...
Y4905142146
Y4905142146

... The distribution static compensator (DSTATCOM) is a shunt active filter, which injects currents into the point of common coupling (PCC) (the common point where load, source, and DSTATCOM are connected) such that the harmonic filtering, power factor correction, and load balancing can be achieved. The ...
Chapter 3 Special-Purpose Diodes
Chapter 3 Special-Purpose Diodes

... The coefficient of coupling between various coils is indicated in Fig. 22.2. In Fig. 22.2(a), the ferromagnetic steel core ensures that most of the flux linking the primary also links the secondary, establishing a coupling coefficient very close to 1. In Fig. 22.2(b), the fact that both coils are o ...
doc - Design Group
doc - Design Group

... As can be seen from this calculation the IRLZ34N is a suitable component for the amount of current. The other consideration when using the component as it was intended was the voltage drop across the component due to the RDS on value of 0.035 (with Vgs of 10 V). Even with the maximum current draw fr ...
< 1 ... 349 350 351 352 353 354 355 356 357 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report