SolidStateKlystronModulators_1SPLColMet - Indico
... • All active electronic components on transformer primary side (medium voltage); • Semiconductor switches of standard commercial types (multisource); • Transformers are not of “pulsed type”. Traditional High Frequency transformer design and construction techniques can be applied; • Flat-top closed l ...
... • All active electronic components on transformer primary side (medium voltage); • Semiconductor switches of standard commercial types (multisource); • Transformers are not of “pulsed type”. Traditional High Frequency transformer design and construction techniques can be applied; • Flat-top closed l ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
... In many CMOS technologies, it is difficult to fabricate resistors with tightly-controlled values or a reasonable physical size. Consequently, it is desirable to replace such resistance with a MOS transistor. A MOSFET can operate as a small-signal resistor if its gate and drain are shorted. The activ ...
... In many CMOS technologies, it is difficult to fabricate resistors with tightly-controlled values or a reasonable physical size. Consequently, it is desirable to replace such resistance with a MOS transistor. A MOSFET can operate as a small-signal resistor if its gate and drain are shorted. The activ ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... efficiency, thermal management, voltage regulation, reliability, power density, and cost. Going forward, these factors will remain critical. A typical breakdown of electricity use and power consumption in data center equipment .It can be observed that computer servers consume more than half of the t ...
... efficiency, thermal management, voltage regulation, reliability, power density, and cost. Going forward, these factors will remain critical. A typical breakdown of electricity use and power consumption in data center equipment .It can be observed that computer servers consume more than half of the t ...
Chuff-Generator
... The C-G is mounted on the curved mount glued to the motor. As you can see, there are no additional spacers. Note also that the sensor is extended from the board to achieve the 1mm spacing in contrast to the previous installation where the sensor was soldered flush to the board. For the larger motor ...
... The C-G is mounted on the curved mount glued to the motor. As you can see, there are no additional spacers. Note also that the sensor is extended from the board to achieve the 1mm spacing in contrast to the previous installation where the sensor was soldered flush to the board. For the larger motor ...
Low Voltage Ride-through Capability Enhancement of Doubly Fed
... RSC from the rotor to protect the converter, while the DFIG operation is changed to a squirrel cage induction generator (SCIG) operation, which absorbs reactive power from the grid. In [8], the authors proposed the use of an energy storage system (ESS) that is connected to the DC-link of DFIG. This ...
... RSC from the rotor to protect the converter, while the DFIG operation is changed to a squirrel cage induction generator (SCIG) operation, which absorbs reactive power from the grid. In [8], the authors proposed the use of an energy storage system (ESS) that is connected to the DC-link of DFIG. This ...
Top 10 “Transformer-based” vs. “Transformerless”
... Response: This may have been true 20 years ago, but today’s transformerless UPSs have internal circuitry, fusing and fast DSP controls that allow the machine to effectively handle internal shorts and external downstream and upstream faults, all while protecting the load and UPS internal components. ...
... Response: This may have been true 20 years ago, but today’s transformerless UPSs have internal circuitry, fusing and fast DSP controls that allow the machine to effectively handle internal shorts and external downstream and upstream faults, all while protecting the load and UPS internal components. ...
AN-6075 Compact Green-Mode Adapter Using FSQ500L for Low Cost 1. Introduction www.fairchildsemi.com
... 2.1 Startup Circuit and Soft Start At startup, an internal high-voltage current source supplies the internal bias and charges the external capacitor (Ca) connected to the VCC pin, as illustrated in Figure 4. An internal high-voltage regulator (HV/REG) located between the D and VCC pins regulates the ...
... 2.1 Startup Circuit and Soft Start At startup, an internal high-voltage current source supplies the internal bias and charges the external capacitor (Ca) connected to the VCC pin, as illustrated in Figure 4. An internal high-voltage regulator (HV/REG) located between the D and VCC pins regulates the ...
First Circuit Breaker for Terminal Blocks
... CHICAGO – December 16, 2002 – E-T-A Circuit Breakers announced a new circuit breaker designed to plug into industry-standard terminal blocks. The 1180 series thermal circuit breaker can reduce costly equipment downtime by replacing the fuses commonly used in DINrail terminal block applications that ...
... CHICAGO – December 16, 2002 – E-T-A Circuit Breakers announced a new circuit breaker designed to plug into industry-standard terminal blocks. The 1180 series thermal circuit breaker can reduce costly equipment downtime by replacing the fuses commonly used in DINrail terminal block applications that ...
Loop Selective Direction Measurement for Distance Protection
... The negative sequence direction measurement is however not one of the first choices of a modern numerical distance protection because it is not suitable for a full scheme distance relay that requires a separate direction decision for each of the six measured loops. For the other alternatives in Tabl ...
... The negative sequence direction measurement is however not one of the first choices of a modern numerical distance protection because it is not suitable for a full scheme distance relay that requires a separate direction decision for each of the six measured loops. For the other alternatives in Tabl ...
Online Full Text
... A metal oxide varistor consists of a bulk semiconductor material (typically sintered granular zinc oxide) that can conduct large currents (effectively short-circuits) when presented with a voltage above its rated voltage. MOVs typically limit voltages to about 3 to 4 times the normal circuit voltage ...
... A metal oxide varistor consists of a bulk semiconductor material (typically sintered granular zinc oxide) that can conduct large currents (effectively short-circuits) when presented with a voltage above its rated voltage. MOVs typically limit voltages to about 3 to 4 times the normal circuit voltage ...
AC Film Capacitors in Connection with the Mains
... energy pulse is applied and the self healing properties are failing (self healing is the ability to recover after a breakdown). As general rule for standard capacitors, not approved according international standards for EMI capacitors, this can happen if surges occur higher than the guaranteed proof ...
... energy pulse is applied and the self healing properties are failing (self healing is the ability to recover after a breakdown). As general rule for standard capacitors, not approved according international standards for EMI capacitors, this can happen if surges occur higher than the guaranteed proof ...
development of a gate drive with overcurrent
... The demand for reliable and high robustness gate driver for power switches is increasing worldwide [1]. It is concomitant with the development of power electronics domain which plays important role for technological enhancement [2]. Most of the conventional gate drive circuit utilize a direct connec ...
... The demand for reliable and high robustness gate driver for power switches is increasing worldwide [1]. It is concomitant with the development of power electronics domain which plays important role for technological enhancement [2]. Most of the conventional gate drive circuit utilize a direct connec ...
QS6U22
... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
VIII .Typical Transmission Line Surge Arrester Installation
... for the insulation design of power system and substation. Whenever lightning strikes the top of a transmission tower, a lightning current flows down to the bottom of the tower and causes a tower voltage to raise and results in a back-flashover across an arc horn. This causes transmission line outage ...
... for the insulation design of power system and substation. Whenever lightning strikes the top of a transmission tower, a lightning current flows down to the bottom of the tower and causes a tower voltage to raise and results in a back-flashover across an arc horn. This causes transmission line outage ...
CA650052EN
... is fully shielded, submersible, and meets the requirements of IEEE Std 386™-2006 standard – Separable Insulated Connector Systems. The design employs a unique, 600 A rated, plated copper probe and mating PUSH-OP bushing utilizing a plated copper finger contact system. The PUSH‑OP connector's sta ...
... is fully shielded, submersible, and meets the requirements of IEEE Std 386™-2006 standard – Separable Insulated Connector Systems. The design employs a unique, 600 A rated, plated copper probe and mating PUSH-OP bushing utilizing a plated copper finger contact system. The PUSH‑OP connector's sta ...
HFBR-5911LZ/ALZ
... 11. The maximum Optical Output Power complies with IEEE 802.3 and is Class 1 laser eye safe. 12. Optical Extinction Ratio is defined as the ratio of the average optical power of the transmitter in the high (“1”) state to the low (“0”) state. The transmitter is driven with a Gigabit Ethernet 1250 MB ...
... 11. The maximum Optical Output Power complies with IEEE 802.3 and is Class 1 laser eye safe. 12. Optical Extinction Ratio is defined as the ratio of the average optical power of the transmitter in the high (“1”) state to the low (“0”) state. The transmitter is driven with a Gigabit Ethernet 1250 MB ...
QS5U27
... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
Magnatone 210 Details
... audio signal to the input of the amplifier in opposite phase potential such that part of the input signal is cancelled out due to the opposite phase relationship of the two signals (the two signals being the input signal and the feedback signal). This serves the purpose of reducing nonlinear ha ...
... audio signal to the input of the amplifier in opposite phase potential such that part of the input signal is cancelled out due to the opposite phase relationship of the two signals (the two signals being the input signal and the feedback signal). This serves the purpose of reducing nonlinear ha ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.