• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
acopos user`s manual (v1)
acopos user`s manual (v1)

... We reserve the right to change the contents of this manual without warning. The information contained herein is believed to be accurate as of the date of publication, however, Bernecker + Rainer Industrie-Elektronik Ges.m.b.H. makes no warranty, expressed or implied, with regards to the products or ...
green book
green book

... Each Distribution Network desires expressly to bring to the attention of users of this publication that the following important matters are applicable to its use. ...
BD2262G-M
BD2262G-M

... (Note 1) Mounted on 70mm x 70mm x 1.6mm glass epoxy board. Reduce 5.4mW per 1°C above 25°C Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins and the internal circuitry. Therefore, it is ...
switchboards
switchboards

DEWA Standards for Distributed Renewable Resources Generators
DEWA Standards for Distributed Renewable Resources Generators

... Apparent Power - Is the product of voltage (in volts) and current (in amperes). It is usually expressed in kilovoltamperes (kVA) or megavolt-amperes (MVA) and consists of a real component (Active Power) and an imaginary component (Reactive Power). In case of inverters, the rated apparent power corre ...
measurement and control of arcing in a submerged-arc
measurement and control of arcing in a submerged-arc

... Charge-chrome furnaces in the industry can vary from a typically low resistance operation to a relatively high resistance operation. The purpose of having a high resistance operation is to facilitate an increase in power delivery within the same electrical constraints for a given furnace installatio ...
g  ESBWR  Design Control Document Tier 2
g ESBWR Design Control Document Tier 2

... 8.2.1.1 Transmission System ........................................................................................ 8.2-1 8.2.1.2 Off-site Power System ...................................................................................... 8.2-1 8.2.2 Analysis........................................ ...
Chapter 8 Prototype - DTUsat-1
Chapter 8 Prototype - DTUsat-1

... (“Electrodynamic Tether for DTUsat”, Feb. 2002) on the investigation and design of an Electrodynamic Tether payload for it. This electrodynamic tether is a long conducting wire, which is deployed from the satellite. As the tether moves through the Earths magnetic field at orbital speeds, electrodyna ...
Sigma-7 Series AC Servo Drive - Yaskawa
Sigma-7 Series AC Servo Drive - Yaskawa

... • Wait for six minutes after turning OFF the power supply and then make sure that the CHARGE indicator is not lit before starting wiring or inspection work. Do not touch the power supply terminals while the CHARGE lamp is lit after turning OFF the power supply because high voltage may still remain i ...
Operating instructions fpr OSRAM DALI Professional Controller
Operating instructions fpr OSRAM DALI Professional Controller

MAX5900/MAX5901 -100V, SOT23/TDFN, Simple Swapper Hot-Swap Controllers General Description
MAX5900/MAX5901 -100V, SOT23/TDFN, Simple Swapper Hot-Swap Controllers General Description

... The MAX5900/MAX5901 are SOT23/TDFN hot-swap controllers that allow a circuit card to be safely hot-plugged into a live backplane without causing a glitch on the power-supply rail. These devices operate from -9V to -100V and provide the simplest hot-swap solution by eliminating all external component ...
Liebert Distribution Monitoring (LDM)
Liebert Distribution Monitoring (LDM)

... national, state and local electrical codes prior to working inside equipment. The area around the equipment must be free of any debris or standing water. All power and control wiring must be installed by a qualified electrician in accordance with the NEC and all applicable national, state and local ...
Virtex-4 PCB 设计指南
Virtex-4 PCB 设计指南

... outer-layer copper for mounting of surface-mount components. Anti-pads are used mainly with vias. Since plated through-hole vias are conductive over the whole length, a method is needed to selectively making electrical connections to traces, planes and planelets of the various layers of a PCB. This ...
LT8490 - Linear Technology
LT8490 - Linear Technology

... operating junction temperature range are assured by design, characterization and correlation with statistical process controls. The LT8490I is guaranteed over the full –40°C to 125°C junction temperature range. Note 4: Do not apply a voltage or current source to these pins. They must be connected to ...
DS1232LP/LPS Low Power MicroMonitor Chip FEATURES PIN ASSIGNMENT
DS1232LP/LPS Low Power MicroMonitor Chip FEATURES PIN ASSIGNMENT

... The watchdog timer function forces RST and RST signals to the active state when the ST input is not stimulated for a predetermined time period. The time period is set by the TD input to be typically 150 ms with TD connected to ground, 600 ms with TD left unconnected, and 1.2 seconds with TD connecte ...
APT 5kV-15kV Metal Clad Drawout Vacuum Circuit Breaker
APT 5kV-15kV Metal Clad Drawout Vacuum Circuit Breaker

Cable Fault Location - HV TECHNOLOGIES, Inc.
Cable Fault Location - HV TECHNOLOGIES, Inc.

... Power supply networks are growing continuously and their reliability is getting more important than ever. The complexity of the whole network comprises numerous components that can fail and interrupt the power supply for the end user. For most of the worldwide operated low voltage and medium voltage ...
AN1790
AN1790

... All digital systems require the power supply to be controlled during power-up and normal operations. Noise resulting from ground loops or switching many signals at once, can create glitches in the power supply which can cause the system to malfunction. For this reason ST has developed a new type of ...
Design and protective measures of a Power Factor
Design and protective measures of a Power Factor

... rating of an appliance gives the rate at which it uses energy. The total amount of energy consumed by this appliance is the wattage multiplied by the amount of time during which it was used; this energy can be expressed in units of watt-hours (or, more commonly, kilowatt-hours). The power dissipated ...
A750 Series, 105°C
A750 Series, 105°C

... Conductive polymer aluminum solid electrolytic capacitors are prone to a change in leakage current due to thermal stress during soldering. The leakage current may increase after soldering or reflow soldering. Therefore, do not use these capacitors in circuits sensitive to leakage current. • Do not ...
SmartPlant Electrical Basic Training Guide
SmartPlant Electrical Basic Training Guide

... Create a Project Generator ................................................................................................ 13 ...
PAM8303C Description Pin Assignments
PAM8303C Description Pin Assignments

... harmonic distortion (THD) as low as possible. Power supply decoupling also prevents the oscillations causing by long lead length between the amplifier and the speaker. The optimum decoupling is achieved by using two different types of capacitors that target on different types of noise on the power s ...
A System for Efficient Neural Stimulation with Energy Recovery Shawn Kevin Kelly
A System for Efficient Neural Stimulation with Energy Recovery Shawn Kevin Kelly

ACS Stepper Hardware & Installation User Guide
ACS Stepper Hardware & Installation User Guide

... It is recommended that the power and signal cables for the ACS Drive be routed as far apart as possible to minimize system noise. NOTE! The standard cables from Tolomatic are not flex rated and have a minimum bend radii of 3.75 inches. Any repeated flexing or excessive bending can result in broken c ...
Baluns: Choosing the Correct Balun
Baluns: Choosing the Correct Balun

... think. The balun has just as much core stress and flux density when placed at the input as it would have when in the traditional location, on the output. Common-mode isolation is also the same as a traditional current balun on the tuner output. Relocating the balun to the input of an unbalanced netw ...
< 1 ... 20 21 22 23 24 25 26 27 28 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.