• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Voltage Collapse Mitigation - pes-psrc
Voltage Collapse Mitigation - pes-psrc

MN225014EN/ Old S225-10-10PSVR
MN225014EN/ Old S225-10-10PSVR

... voltage levels within programmed limits to improve power quality and are compatible with SCADA and automation distribution systems. Available in single-phase, 2-in-1 and 3-in-1 configurations, Eaton's pad-mounted voltage regulators are suitable for three- or four-wire underground systems. The 2-in-1 ...
Uses for TPS cables
Uses for TPS cables

... Neutral screened cable—These are circular cables with a copper screen surrounding the actives that is intended to be the neutral conductor Screened cable—Circular TPS cables with copper braided screens are commonly used for the connections between induction motors and variable frequency drives. The ...
MIG Series OPERATOR MANUAL wilkinsonstar.com MIG/MAG/MMA Separate wire feed welding  machine
MIG Series OPERATOR MANUAL wilkinsonstar.com MIG/MAG/MMA Separate wire feed welding machine

... equipment. Operators should ...
Domestic_Defrost
Domestic_Defrost

... • The impedance of the timer motor is much greater than the resistance of the heater • For this reason almost all the voltage of this circuit is dropped across the timer motor. • The impedance of the timer motor also limits the current flow throughout the defrost heater to such an extent that it doe ...
FAN6920MR ™ Technology Integrated Critical-Mode PFC mWSaver and Quasi-Resonant Current-Mode PWM Controller
FAN6920MR ™ Technology Integrated Critical-Mode PFC mWSaver and Quasi-Resonant Current-Mode PWM Controller

... PFC inductor winding to detect the ZCD voltage signal once the PFC inductor current discharges to zero. When the ZCD voltage signal is detected, the controller starts a new PFC switching cycle. When the ZCD pin voltage is pulled to under 0.2 V (typical), it disables the PFC stage and the controller ...
The Complete Guide to Electrical Insulation Testing
The Complete Guide to Electrical Insulation Testing

... However, most equipment is capacitive and so your very first spot reading on equipment in your plant, with no prior tests, can be only a rough guide as to how good or bad the insulation is. For many years, maintenance professionals have used the one-megohm rule to establish the allowable lower limit ...
BD768xFJ-LB series Quasi-Resonant converter Technical Design
BD768xFJ-LB series Quasi-Resonant converter Technical Design

... BD768xFJ-LB series has overload protection correction function in the input voltage. After the IC detects overload, there is a delay time to stop the switching operation. This delay is to increase the overload protection point with an increase input voltage. Correction function reduces the current d ...
Keysight Technologies B2900 Series Precision Source/Measure Unit
Keysight Technologies B2900 Series Precision Source/Measure Unit

... For connecting a DUT, you can choose the connection type 2-wire connection or 4-wire connections. If you want to simplify the connections, use the 2-wire connections by connecting the Force terminals only. Then open the Sense terminals. The Force terminals can be used to apply and measure dc voltage ...
BU4538B
BU4538B

... extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our Prod ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... Each EPSS division contains a low voltage regulating transformer that powers MCCs BNB02 and BNB03. The low voltage regulating transformer maintains the voltage at or above a minimum level to meet electrical requirements of MCC loads (primarily motor-operated valves) during EPSS system voltage transi ...
DC-Arc Models and Incident-Energy Calculations
DC-Arc Models and Incident-Energy Calculations

... the literature deals with arcs that have been constrained or stabilized.” They also noted that “The bulk of the arc literature is based on single-phase opposing electrodes, where the current comes from one side and flows across to the other side” [1]. Series electrodes have historically received the ...
Distribution Transformers
Distribution Transformers

... Transformers for variable speed drives: These units can be supplied with primary power ratings up to 30 MVA. They can be supplied as oil type or dry type. Converter transformers can be used for the variable speed drives of high-load, low-speed equipment such as mine hoists, rolling mills and ship pr ...
Fuse Facts - Marine Electricity
Fuse Facts - Marine Electricity

... VOLTAGE RATING: The voltage rating, as marked on a fuse, indicates that the fuse can be relied upon to safely interrupt its rated short circuit current in a circuit where the voltage is equal to, or less than, its rated voltage. This system of voltage rating is covered by N.E.C. regulations and is a ...
HID Ballast Application Guide | GE Lighting
HID Ballast Application Guide | GE Lighting

... opposed to the Magnetically Regulated circuit. The circuit consists of a high reactance autotransformer with a capacitor in series with the lamp resulting in a high power factor ballast. A CWA ballast also has a significantly lower dropout voltage (the voltage at which the lamp extinguish) than the ...
Insulated Gate Bipolar Transistor (IGBT)
Insulated Gate Bipolar Transistor (IGBT)

Generator Protection - My Protection Guide
Generator Protection - My Protection Guide

The CMN module
The CMN module

... Zoomed View, red line depicts average system noise ...
PDF copy - Alain Destexhe
PDF copy - Alain Destexhe

... is held fixed; in voltage clamp mode, the potential at the amplifier input is held fixed (using a feedback circuit). When two intracellular electrodes are used (in addition to the reference electrode), one electrode injects a current and the other one measures the potential. When only one intracellu ...
anti-theft systems - Pearson Higher Education
anti-theft systems - Pearson Higher Education

TEK P6205 Instruction
TEK P6205 Instruction

... offset and additional voltage sources, are not required by the P6205; therefore, the contact pins are omitted from the connector. NOTE. Your oscilloscope may not implement all features of the TEKPROBE interface. Refer to your oscilloscope manual for details. BNC Locking Ring. The BNC locking ring ho ...
Cable System Transient Study
Cable System Transient Study

Master Examination Practice Drill #1 2011
Master Examination Practice Drill #1 2011

Third Rail Fuse Link Application Guide
Third Rail Fuse Link Application Guide

... Third rail railway systems are used for many urban, metro and subway railways throughout the world. They are characterised by the power being supplied by a live outside third rail and returned through the wheels to the earthed running rails. Alternatively, a center fourth rail, isolated from the run ...
ON REDUCTION OF SUBSTRATE NOISE IN MIXED-SIGNAL CIRCUITS Erik Backenius
ON REDUCTION OF SUBSTRATE NOISE IN MIXED-SIGNAL CIRCUITS Erik Backenius

< 1 ... 16 17 18 19 20 21 22 23 24 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report