• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Technical Information
Technical Information

... The temperature range of this material can vary from -55°C to 90°C. The actual range would depend on the formulation used. Neoprene is both oil-resistant and sunlightresistant, making it ideal for many outdoor applications. The most stable colors are Black, Dark Brown, and Gray. The electrical prope ...
Mounting Instruction
Mounting Instruction

... • Do not penetrate the device's interior with any kind of object. • During installation or any other work in the switching cabinet, protect the device against falling parts (pieces of wire, stranded wire, pieces of metal, and so on). Parts with conductive properties may cause a short circuit within ...
Power engineering
Power engineering

... Although the PDU and module power supplies differ in AC- and DC-powered systems, power distribution is similar: power is input to the pedestal and distributed to individual power supplies in each module. In AC-powered systems, the module power supplies convert the AC voltage to several usable DC vol ...
Basic Electrostatic Spray Finishing
Basic Electrostatic Spray Finishing

... electric fields are used to attract particles of atomized coating material to the target (the object to be coated). In the most common types of electrostatic systems, electrical charges are applied to the coating material and the target is grounded, creating an electric field. The charged particles ...
UNIVERSITY OF CALIFORNIA, SAN DIEGO CMOS Power Amplifiers for Wireless Communications
UNIVERSITY OF CALIFORNIA, SAN DIEGO CMOS Power Amplifiers for Wireless Communications

Switch Ratings, What`s it all Mean?
Switch Ratings, What`s it all Mean?

... never seen a manual switch weld shut. I've seen them corrode open, I've seen over-center springs rust out, I've see wires break off the back, etc. But never a welding. Now, contactors weld . . . with some frequency . . . but that's another topic. Electrical stresses that weld switch contacts in the ...
2.12 The Simple Fuse
2.12 The Simple Fuse

chapter i - Sacramento - California State University
chapter i - Sacramento - California State University

... and alternative electric power supply has been significantly increasing. Any type of electric power generation resource including solar Photo-Voltaic (PV), small gas turbines, fuel cells, and/or wind turbines, interconnected to distribution system is referred to as DG. DG is perceived to provide vol ...
The Role of Isolation Transformers in Data Center UPS Systems
The Role of Isolation Transformers in Data Center UPS Systems

... The dual mains configuration is required when the bypass is fed from a second mains that is different from the mains feeding the UPS rectifier input. The difference in the mains can range from minor (e.g., they are fed from different breakers on the same panel) to major (e.g. they come from complete ...
AI044230235
AI044230235

... operation fastens. The carry-select adder is one of the faster types of adders, and has smaller area overhead than all other types of adders except for the carryskip adder. The main difference between a carryselect adder and a ripple-carry adder is that in a ripple-carry adder the carry has to rippl ...
Dry Type Transformers
Dry Type Transformers

... is magnetically induced between the primary and secondary. As such, twowinding transformers isolate the load circuit from the supply circuit. Autotransformers are specially designed transformers consisting of one continuous winding. The primary and secondary are electrically connected. The required ...
Dynaco ST70 - thehistoryofrecording.com
Dynaco ST70 - thehistoryofrecording.com

... on hand the origin of which is doubtful it is wise to obtain new 50/50 or 60/40 l' a sin core solder. Whenever sol del' in g is required, the assembly instructions specify it by "(S)." If this symbol is not shown aiter a connection is specified, it indicates that further connections will be made at ...
cable terminology
cable terminology

... Messenger : A bare cable used for its strength characteristics to support power conductors and insulated power cables. A messenger can be used as a conductor, partial conductor, or nonconductor. Milliken conductors : With alternating current there is a tendency for more of the current to be carried ...
Table of Contents HARTMAN Power Switching Contactors
Table of Contents HARTMAN Power Switching Contactors

... please visit www.te.com ...
MN202001EN/ Old S210-12-1
MN202001EN/ Old S210-12-1

... nameplate. Reduced BIL can result in an internal dielectric breakdown with a risk of explosion, tank rupture, or fire. To maintain full cabinet security, the transformer tank and cabinet base have provisions for installing cleats to secure transformer to pad. If gaps still exist between the cabinet ...
Transmission to Distribution/ End-User Interconnection Guidelines
Transmission to Distribution/ End-User Interconnection Guidelines

... Upon completion of the interconnection study and acceptance of the required interconnection facilities, DPC and the distribution project developer shall notify the reliability entities of the modified existing or new transmission facilities required for this transmission to distribution interconnect ...
CMPWR150 - 500 mA/3.3 V SmartOR TM Power Regulator
CMPWR150 - 500 mA/3.3 V SmartOR TM Power Regulator

On-Chip Transient Detection Circuit for System
On-Chip Transient Detection Circuit for System

Molded Case Circuit Breakers
Molded Case Circuit Breakers

... necessary to keep the current from exceeding the conductor’s continuous current rating. ...
Manual
Manual

... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
Procedures and Qualifications Operators must establish procedures
Procedures and Qualifications Operators must establish procedures

- aes journals
- aes journals

switchboard multi-metering
switchboard multi-metering

... Provide interlocks to prevent racking the circuit breaker unless the breaker is open b. Ratings: Interrupting up to 100 kA at 480V without fuses. Short time current ratings for each circuit breaker shall be as indicated on the drawings or data tables. Circuit breakers shall be 600-volt class. c. Ope ...
Control of Multi-terminal VSC-HVDC Systems
Control of Multi-terminal VSC-HVDC Systems

Three-Phase Transformer Banks - Lab-Volt
Three-Phase Transformer Banks - Lab-Volt

... The need for innovative technologies to make the grid smarter has recently emerged as a major trend, as the increase in electrical power demand observed worldwide makes it harder for the actual grid in many countries to keep up with demand. Furthermore, electric vehicles (from bicycles to cars) are ...
< 1 ... 19 20 21 22 23 24 25 26 27 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.