• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BASS INDUSTRIES
BASS INDUSTRIES

... The installer is responsible for ensuring that the mounting structure and hardware are capable of supporting the display, and the structure follows all local codes. Because every installation site is unique, no single procedure is approved by Bass Industries displays. The information contained in th ...
Distributed Generation in Power System Network to Alleviate
Distributed Generation in Power System Network to Alleviate

... creating problems such as deterioration of power quality, outages and grid instability. Due to exhaustion of traditional energy sources and increasing price in the generation of electric power had raised interest in the production of electric energy from renewable power sources to balance the energy ...
- ijsetr.
- ijsetr.

87KB - IEEE International Reliability Innovations Conference
87KB - IEEE International Reliability Innovations Conference

- IEEE Mentor
- IEEE Mentor

... Accessory on/off control and monitoring functions should also be controlled by the same computer. Each computer should be capable of independent operation and be able to perform all essential control functions without being connected to any other computer. This suggests that each separate major HVAC ...
Evaluates:  MAX1711 MAX1711 Voltage Positioning Evaluation Kit General Description Features
Evaluates: MAX1711 MAX1711 Voltage Positioning Evaluation Kit General Description Features

LM4041  PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES Description
LM4041 PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES Description

... the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance w ...
Li, J., T. Yuan, Q. Yang, W. Sima, C. Sun, and M. Zahn, Numerical and Experimental Investigation of Grounding Electrode Impulse-Current Dispersal Regularity Considering the Transient Ionization Phenomenon , IEEE Transactions on Power Delivery, Vol. 26, No. 4, pages 2647-2658, October, 2011
Li, J., T. Yuan, Q. Yang, W. Sima, C. Sun, and M. Zahn, Numerical and Experimental Investigation of Grounding Electrode Impulse-Current Dispersal Regularity Considering the Transient Ionization Phenomenon , IEEE Transactions on Power Delivery, Vol. 26, No. 4, pages 2647-2658, October, 2011

SA-600R Series Pure Sine Wave Inverter User`s Manual
SA-600R Series Pure Sine Wave Inverter User`s Manual

... that they functioned properly when connected to the output of the Inverter. ...
EET 3092 SWITCHGEAR AND PROTECTION
EET 3092 SWITCHGEAR AND PROTECTION

HMC284MS8G / 284MS8GE
HMC284MS8G / 284MS8GE

Welding machines: V and HB series IGBTs on two
Welding machines: V and HB series IGBTs on two

... hence the DC voltage output signal has a small switching ripple. The new ST 600 V/650 V IGBT technologies with trench gate field-stop structures are specifically tailored to meet the needs of this topology in single phase main, where the working frequency is generally set to ~60kHz, exhibiting the h ...
RF3701 数据资料DataSheet下载
RF3701 数据资料DataSheet下载

... RF input internally matched to 50  and DC blocked. The RF input matching circuit has a shunt inductor to ground which would short any DC voltage placed on this pin. No connection. Digital control input for power mode selection (see Operating Modes truth table). Digital control input for PA enable a ...
BDTIC ICE2QS02G Quasi-Resonant PWM Controller
BDTIC ICE2QS02G Quasi-Resonant PWM Controller

2 DIODE CLIPPING and CLAMPING CIRCUITS
2 DIODE CLIPPING and CLAMPING CIRCUITS

... voltage, technically called “threshold voltage” and can be changed to a desired value by inserting a D.C. voltage source. This is achieved in two different ways. In the first type, the voltage source of Em ( positive or negative) is connected through output terminals as in Fig. 2.4. Depending on the ...
FEATURES FUNCTIONAL BLOCK DIAGRAM
FEATURES FUNCTIONAL BLOCK DIAGRAM

... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
บทที่ 6 Special Transformers
บทที่ 6 Special Transformers

... • Because current transformers (CTs) are only used for measurement and system protection, their power rating is small-generally between 15 VA and 200 VA. • For safety reasons current transformers must always be used when measuring currents in HV transmission lines. ...
MAX1639 High-Speed Step-Down Controller with Synchronous Rectification for CPU Power ________________General Description
MAX1639 High-Speed Step-Down Controller with Synchronous Rectification for CPU Power ________________General Description

transformers - Crompton Instruments
transformers - Crompton Instruments

... A transformer is a device that transfers electrical energy from one circuit to another by electromagnetic induction (also called transformer action). It is most often used to step up or step down voltage. Occasionally, it is used as an isolating device to eliminate a direct mechanical electrical con ...
Al-Balqa` Applied University Faculty of Engineering Technology
Al-Balqa` Applied University Faculty of Engineering Technology

... Investigation of motor electro-mechanical and torque-speed regulated characteristics for star connection of stator windings by: 1- Adding Resistances in rotor circuit. 2- Varying stator voltage using autotransformer. Experiment procedures carrying out: 1- Investigation of motor electro-mechanical an ...
Lightplane 1 Recessed (LP1R) Install Instructions
Lightplane 1 Recessed (LP1R) Install Instructions

... must be independently supported from the fixture and spaced to fit the fixture width and length before installing the fixture. 6. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver o ...
Modelling of Nonlinear Loads and Estimation of Harmonics
Modelling of Nonlinear Loads and Estimation of Harmonics

... voltage distortion caused by the harmonic-producing load is a function of both the system impedance and the amount of harmonic current injected [1]. The mere fact that a given load current is distorted does not always mean there will be undue adverse effects on other power consumers [2],[3]. If the ...
electric phenomena in relation to lubrication .` of machines
electric phenomena in relation to lubrication .` of machines

... than the molecules in the oil itself. This suggests that oil is not an electrolyte, but impurities dissolved in the oil materially affect its electrical characteristics. In Michie's experiments on insulating oils he was unable to cause the oil to deposit any precipitate merely by an electrical stres ...
Latchable Negative Floating Hot Swap Power
Latchable Negative Floating Hot Swap Power

... The UCC3921 family of negative floating hot swap power managers provides complete power management, hot swap, and fault handling capability. The IC is referenced to the negative input voltage and is powered through an external resistor connected to ground, which is essentially a current drive as opp ...
MEASUREMENTS OF ELECTRICAL QUANTITIES
MEASUREMENTS OF ELECTRICAL QUANTITIES

< 1 ... 210 211 212 213 214 215 216 217 218 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report