seminar - Voltimum
... Operating condition in an electrically damaged circuit where there is an accidental or intentional connection by a relatively low resistance between two points of a circuit which are normally at different voltages ...
... Operating condition in an electrically damaged circuit where there is an accidental or intentional connection by a relatively low resistance between two points of a circuit which are normally at different voltages ...
MAINTENANCE OF MECHANICAL AND ELECTRICAL EQUIPMENT
... conditions of wear. Always paint metal surfaces before corrosion becomes so severe that equipment is damaged. Surfaces must be prepared before they can be painted; sandblast metal surfaces if practical or clean them thoroughly with sandpaper and a wire brush. Paint should be mixed properly and scree ...
... conditions of wear. Always paint metal surfaces before corrosion becomes so severe that equipment is damaged. Surfaces must be prepared before they can be painted; sandblast metal surfaces if practical or clean them thoroughly with sandpaper and a wire brush. Paint should be mixed properly and scree ...
Autotransformers - ELHAND Transformatory
... three-phase autotransformers of the EA1, EA3-type and start-up transformers of the EA3R-type ...
... three-phase autotransformers of the EA1, EA3-type and start-up transformers of the EA3R-type ...
eet 3086 power transmission and distribution
... current transformers and overcurrent relays (four instead of six). Furthermore, this allows the same line current transformers to be used for both overcurrent protection and earth fault protection, by connecting the neutral point of the transformers to that of the overcurrent relays through an earth ...
... current transformers and overcurrent relays (four instead of six). Furthermore, this allows the same line current transformers to be used for both overcurrent protection and earth fault protection, by connecting the neutral point of the transformers to that of the overcurrent relays through an earth ...
Chapter02
... cases, motherboards, and power supplies • Learn how electricity is measured and about electrical components • Learn how to select a power supply • Learn how to protect yourself and your equipment against the dangers of electricity • Learn how to work inside a computer case • Learn how to troubleshoo ...
... cases, motherboards, and power supplies • Learn how electricity is measured and about electrical components • Learn how to select a power supply • Learn how to protect yourself and your equipment against the dangers of electricity • Learn how to work inside a computer case • Learn how to troubleshoo ...
1 .8 Differentiating EMC ferrite ↔ inductor
... In reality, there are other factors that affect the behavior of transformers. The most important ones are: • Leakage inductance • Coupling capacitance (capacitance between windings) • Winding capacitance (capacitance within a winding) Leakage inductance Looking at two windings, we see that the en ...
... In reality, there are other factors that affect the behavior of transformers. The most important ones are: • Leakage inductance • Coupling capacitance (capacitance between windings) • Winding capacitance (capacitance within a winding) Leakage inductance Looking at two windings, we see that the en ...
Chapter 8 – Methods of Analysis and Selected Topics (dc)
... networks may appear in one of three forms as indicated below The ...
... networks may appear in one of three forms as indicated below The ...
QPI-8 - Vicor
... and a capacitor (CE), the UVEN pin can be filtered from reacting immediately to a transient loss of power, thereby maintaining a high PWRGD status and allowing the converter to run off of its bulk capacitors. There is a practical limit to the amount of bulk capacitance that can be used as an energy ...
... and a capacitor (CE), the UVEN pin can be filtered from reacting immediately to a transient loss of power, thereby maintaining a high PWRGD status and allowing the converter to run off of its bulk capacitors. There is a practical limit to the amount of bulk capacitance that can be used as an energy ...
The high voltage (HV) pulse radiation of a discone antenna
... few hundreds of kilo volts, it is quite obvious that the antenna cannot be fed like any other antenna, with a coaxial cable as in the case of [6]. Hence, here radiation is intended to achieve by corona charging mechanism[10]. Here the cone element of the antenna is grounded while the disc is fed wit ...
... few hundreds of kilo volts, it is quite obvious that the antenna cannot be fed like any other antenna, with a coaxial cable as in the case of [6]. Hence, here radiation is intended to achieve by corona charging mechanism[10]. Here the cone element of the antenna is grounded while the disc is fed wit ...
Voltage Stability Analysis of Radial Distribution Networks with
... requires examination of lots of system states and many contingency scenarios. For this reason the approach based on steady state analysis is more feasible, and it can also provide global insight of the voltage reactive power problems [2]. The voltage stability phenomenon has been well recognized in ...
... requires examination of lots of system states and many contingency scenarios. For this reason the approach based on steady state analysis is more feasible, and it can also provide global insight of the voltage reactive power problems [2]. The voltage stability phenomenon has been well recognized in ...
TITLE: Quality Objectives
... Alternating current machines: Manual arc welding and cutting – 80 volts (V) Automatic arc welding and cutting – 100 V Direct current machines: Manual & automatic welding & cutting - 100V When special welding and cutting processes require valves or open circuit voltages higher than listed above ...
... Alternating current machines: Manual arc welding and cutting – 80 volts (V) Automatic arc welding and cutting – 100 V Direct current machines: Manual & automatic welding & cutting - 100V When special welding and cutting processes require valves or open circuit voltages higher than listed above ...
light-controlled mixer
... a voltage source (in our case, an audio signal) and splits it up between two resistors. If one resistor has a higher resistance (measured in ohms) than the other, it will get a proportionately higher share of the signal. A resistor that is more than ten times the value of the other resistor will get ...
... a voltage source (in our case, an audio signal) and splits it up between two resistors. If one resistor has a higher resistance (measured in ohms) than the other, it will get a proportionately higher share of the signal. A resistor that is more than ten times the value of the other resistor will get ...
Power Electronic Device Protection (VFD, Drive Protection)
... which it was tested). It does not have to be marked with the type overcurrent protective device if it has followed certain procedures. However, the manufacturer can list the drive with fuse protection only and then the label will be marked to identify that branch-circuit protection shall be provided ...
... which it was tested). It does not have to be marked with the type overcurrent protective device if it has followed certain procedures. However, the manufacturer can list the drive with fuse protection only and then the label will be marked to identify that branch-circuit protection shall be provided ...
A compact, high voltage 25kW, 50 kHz DC
... are presented in Section V. In Fig. 5 the turn off losses for the nominal voltage of 350 V are given. There, the losses at (25 ◦ C) have been measured and as could be seen, these correspond very well to the losses given in the data sheet. Therefore, the loss data for a junction temperature of 125 ◦ ...
... are presented in Section V. In Fig. 5 the turn off losses for the nominal voltage of 350 V are given. There, the losses at (25 ◦ C) have been measured and as could be seen, these correspond very well to the losses given in the data sheet. Therefore, the loss data for a junction temperature of 125 ◦ ...
Lecture2 - WordPress.com
... Alternating voltage and current • Electricity is produced by generators at power station. • Electricity is then distributed by a vast network of transmission lines called National Grid System. • It is easier and cheaper to generate AC than DC. • It is more convenient to distribute AC than DC since ...
... Alternating voltage and current • Electricity is produced by generators at power station. • Electricity is then distributed by a vast network of transmission lines called National Grid System. • It is easier and cheaper to generate AC than DC. • It is more convenient to distribute AC than DC since ...
dl 2617 six pulse control unit
... Technical features: The power supply has two sections: •Regulated variable voltage section, used to supply the armature of dc motors. Output: 0 ÷ 240 Vdc, 5 A Drive: manual or external via 0 ÷ 10 Vdc signal •Constant voltage section, used to supply the excitation circuit of dc machines. Output: 220 ...
... Technical features: The power supply has two sections: •Regulated variable voltage section, used to supply the armature of dc motors. Output: 0 ÷ 240 Vdc, 5 A Drive: manual or external via 0 ÷ 10 Vdc signal •Constant voltage section, used to supply the excitation circuit of dc machines. Output: 220 ...
Genius Voltage/Current Analog I/O Blocks datasheet, GFK
... Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave ...
... Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave ...
SCB-100 Installation Guide
... The following cautions contain important safety information concerning hazardous voltages and connector blocks. Caution To avoid electrical shock, do not remove equipment covers or shields unless you are qualified to do so. If signal wires are connected to the SCB-100, hazardous voltages may exist e ...
... The following cautions contain important safety information concerning hazardous voltages and connector blocks. Caution To avoid electrical shock, do not remove equipment covers or shields unless you are qualified to do so. If signal wires are connected to the SCB-100, hazardous voltages may exist e ...
Fundamentals of Linear Electronics Integrated & Discrete
... each digit is lit in a continuous sequence (1,2,3,4,1,2,3,4...) how much power would the display use? ...
... each digit is lit in a continuous sequence (1,2,3,4,1,2,3,4...) how much power would the display use? ...
Document
... source of emf. When current flows, however, the voltage across the terminals of the source of emf is no longer the open-circuit value, due to voltage drops inside the device due to its internal resistance Suppose a source of emf “E” is connected with a resistance, say load “R”, through which uniform ...
... source of emf. When current flows, however, the voltage across the terminals of the source of emf is no longer the open-circuit value, due to voltage drops inside the device due to its internal resistance Suppose a source of emf “E” is connected with a resistance, say load “R”, through which uniform ...
Genius Voltage/Current Analog I/O Blocks datasheet, GFK
... Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave ...
... Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave ...
Drive Circuits
... • Signal processing circuits which generate the logic control signals not considered part of the drive circuit • Drive circuit amplifies control signals to levels required to drive power switch • Drive circuit has significant power capabilities compared to logic level signal processing circuits ...
... • Signal processing circuits which generate the logic control signals not considered part of the drive circuit • Drive circuit amplifies control signals to levels required to drive power switch • Drive circuit has significant power capabilities compared to logic level signal processing circuits ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.