• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Title Electrical and Thermal Characteristics of Household Appliances
Title Electrical and Thermal Characteristics of Household Appliances

... These potential impacts of harmonics mean that regulation of electromagnetic compatibility (EMC) is of crucial importance. Current EU directive on EMC, [6], repealed directive [7], regulating EU wide electrical standards in relation to electrical equipment and appliances. That directive refers to a ...
Ch1 RLC Load - Bridging Theory into Practice
Ch1 RLC Load - Bridging Theory into Practice

... circuit to the flow of alternating current that is analogous to the actual electrical resistance to a direct current. • The impedance of a circuit element represents its resistive and/or reactive components ...
ADP3334 数据手册DataSheet 下载
ADP3334 数据手册DataSheet 下载

... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADP3334 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
AAT4625 数据资料DataSheet下载
AAT4625 数据资料DataSheet下载

... TSD(MIN) is the minimum temperature required to activate the device over-temperature protection. The typical thermal limit temperature specification is 125°C for the AAT4625; for calculations, 115°C is a safe minimum value. For example, a portable device is specified to operate in a 50°C environment ...
MAX5051 Parallelable, Clamped Two-Switch Power
MAX5051 Parallelable, Clamped Two-Switch Power

... The MAX5051 is a clamped, two-switch power-supply controller IC. This device can be used both in forward or flyback configurations with input voltage ranges from 11V to 76V. It provides comprehensive protection mechanisms against possible faults, resulting in very high reliability power supplies. Wh ...
50mA-20A, Single-Supply, Low-Side or High
50mA-20A, Single-Supply, Low-Side or High

... is intended to be accurately measured. When configured in a low-side current sensing solution the common mode voltage applied to the amplifier is essentially zero and in many cases can be ignored. This allows the designer to choose an amplifier that may not have very high common mode rejection ratio ...
Transformerless Power Supply Design
Transformerless Power Supply Design

Quad DMOS Full Bridge PWM Motor Driver A3988
Quad DMOS Full Bridge PWM Motor Driver A3988

... to an exposed surface on the PCB. Thermal vias are used to transfer heat to other layers of the PCB. ...
ABB drives - Technical guide No. 5 - Bearing currents in modern AC
ABB drives - Technical guide No. 5 - Bearing currents in modern AC

... between the stator windings and the motor frame. This capacitance is distributed around the circumference and length of the stator. As the current leaks into the stator along the coil, the high frequency content of the current entering the stator coil is greater than the current leaving. This net cu ...
A Distributed Static Series Compensator System for
A Distributed Static Series Compensator System for

... Unfortunately, ac power flow follows Ohm’s Law, not contract law. Uncontrolled ‘loop flow’ causes congestion and reliability problems, and reduces the ability to fulfill energy contracts. Loop flows also impact the ability to fully utilize certain transmission lines, even as other lines suffer conge ...
Unit 10 Lab - TTU Physics
Unit 10 Lab - TTU Physics

EM8559A
EM8559A

... increases cycle-by-cycle current limit comparator inverting input voltage slowly after it starts. The typical soft-start time is 3.5mS. The pulse width to the power MOSFET is progressively increased to establish the correct working conditions for transformers, rectifier diodes and capacitors. The vo ...
GEK-98000B-P Power/Vac Electrically Operated 15kV Ground
GEK-98000B-P Power/Vac Electrically Operated 15kV Ground

... The equipment described in this document may contain high voltages and currents which can cause serious injury or death. The equipment is designed for use, installation, and maintenance by knowledgeable users of such equipment having experience and training in the field of high voltage electricity. ...
Test Point Diagram
Test Point Diagram

... Measure the resistance in the following points (connectors, etc.). If they are short-circuited, it means that they are broken. 1. Check of DIP-IPM P-U, P-V, P-W, N-U, N-V, N-W 2. Check of DIP-PFC P-R, P-S, R-N, S-N ...
MAX40200 - Part Number Search
MAX40200 - Part Number Search

... blocks reverse-voltages and passes current when forwardbiased just as a normal diode. The improvements are that instead of a cut-in voltage around 500mV and a logarithmic voltage-current transfer curve, the MAX40200 has a near constant voltage drop independent of the magnitude of the forward current ...
2009 30 Spring Wiring Matters
2009 30 Spring Wiring Matters

... the control of the person relying upon the safe isolation remaining effective. Similarly where a fuse has been removed to effect isolation, the fuse and any spare fuses in close proximity to the distribution board or consumer unit should be retained under the control of the person relying upon the i ...
ADP3331 数据手册DataSheet 下载
ADP3331 数据手册DataSheet 下载

... circuit against damage due to excessive power dissipation. Thermal protection limits the die temperature to a maximum of 165∞C. Under extreme conditions (i.e., high ambient temperature and power dissipation) where the die temperature starts to rise above 165∞C, the output current will be reduced unt ...
Poor Man`s 1-GHz
Poor Man`s 1-GHz

... the components are surface mounted (SMD), but assembly by hand is reasonably easy with a fine tipped soldering iron and tweezers. The parts are assembled on one side of a double sided 1.6-mm thick PCB. Connections are made between the ground plane on each side of the board with solid wire soldered o ...
B. Tech. (Electrical Engineering)
B. Tech. (Electrical Engineering)

... EHU-301/ EHU-302 ...
TD-1 Manual - Millennia Media
TD-1 Manual - Millennia Media

... 3. Read this manual carefully and completely before attempting to use the TD-1. Improper operation could result in damage to product. It is the user’s responsibility to understand the safe use and operation of this device. 4. The shipping box of the TD-1 system will include (1) Owner’s Manual, (2) T ...
2SC5001
2SC5001

... 3) Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating char ...
RF2472 2.4GHz LOW NOISE AMPLIFIER WITH ENABLE Features
RF2472 2.4GHz LOW NOISE AMPLIFIER WITH ENABLE Features

Diode Circuits
Diode Circuits

... prediction of the current-voltage relationship of the PN junction itself - especially the temperature variation - and can be improved somewhat by choosing Io and VT empirically to fit a particular diode. € However, for a real diode, other factors are also important: in particular, edge effects aroun ...
IET LABS, INC. 1864-1644 Positive Polarity Megohmmeter
IET LABS, INC. 1864-1644 Positive Polarity Megohmmeter

... WARNING High voltage is applied to the measurement terminals of 1864-1644 Megohmmeters at all times, except when the function switch is set to DISCHARGE. While the current is limited to a value that is not dangerous under most conditions, the energy stored in a capacitor connected to the terminals m ...
< 1 ... 166 167 168 169 170 171 172 173 174 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report