• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Static Neutralizing Systems - Simco-Ion
Static Neutralizing Systems - Simco-Ion

Summary of risks with conductive and non-conductive plastic
Summary of risks with conductive and non-conductive plastic

... A small number of scientific studies relating to insulating pipe voltages in petrol station applications have been reported. From an assessment of these results it can be concluded that: o Because of the relatively short exposed pipe lengths it is likely that only moderate voltages are developed in ...
Operating instructions R4D630RB1501 - ebm
Operating instructions R4D630RB1501 - ebm

... ; Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment. ; Protect the device from environmental impacts and dirt until the final installation. ; We recommend storing the device for a maximum up to one year to guarantee proper ...
Capacitors for Power Factor Correction
Capacitors for Power Factor Correction

... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
Liebert Series 610 UPS DISCONTINUED PRODUCT

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
Time-Current Curves (How to Read)
Time-Current Curves (How to Read)

... The longer an overcurrent is permitted to flow the greater the potential for component damage. The primary function of an overcurrent protective device is to provide protection to circuit components and equipment. A short-time delay (STD) setting on a circuit breaker can negate the function of prote ...
Mapping Nodal Power Injections to Branch Flows in
Mapping Nodal Power Injections to Branch Flows in

... nodes—we demonstrate that only the voltage phasors at the nodes with nonzero external current injections are required to recover the flows on all the lines. The most obvious application of these expressions would be in the fair usage allocation of transmission lines in an AC power system network. Ho ...
Owner`s Manual
Owner`s Manual

... While your PowerCenter does an excellent job of protecting your components from harmful power surges, its main benefit is much more than just surge protection. Our exclusive Clean Power™ filter circuitry virtually stops the noise that goes right through typical surge protectors. There is more than o ...
Authorisation Remember..... If it`s not safe, don`t do it
Authorisation Remember..... If it`s not safe, don`t do it

... Dead work - Install, repair, inspect, test and connect electrical circuit conductors and electrical equipmwnt, ensuring that they conform to the relevant regulations Issue LV Permits to work Receive LV permits to work Issue sanction for work near live conductors Receive sanction for work near live c ...
64WKS_Installation_en-UK_RevA
64WKS_Installation_en-UK_RevA

... This device enables the generation of a highly dynamic speed or torque/current control circuit. The actual speed is measured either by the electronic rectification of the three-phase (brushless) tachometer signal or by the feedback of a DC tachometer signal. All the variable adjustment parameters an ...
MAX4785–MAX4788 50mA/100mA Current-Limit Switches General Description Features
MAX4785–MAX4788 50mA/100mA Current-Limit Switches General Description Features

... The MAX4785–MAX4788 are forward/reverse currentlimited switches that operate from a 2.3V to 5.5V input voltage range and guarantee a 50mA and 100mA minimum current-limit threshold for different options. The voltage drop across an internal sense resistor is compared to two reference voltages to indic ...
CA132045EN/ Old 240-93
CA132045EN/ Old 240-93

... time will vary with the value and duration of fault current pulses. For high values of fault current, particularly where the upstream recloser is operating in delayed mode, the ASL reclaim time may extend by up to 15% while for instantaneous tripping operation at lower values of current near the pic ...
VPhase VX1 Technical Specification
VPhase VX1 Technical Specification

... The inclusion of separate RCBO for one lighting circuit ensures segregation between lighting circuits. Many other consumer unit configurations are possible. Example circuits for VX1 to supply ...
Chapter 3 VOLTAGE CONTROL
Chapter 3 VOLTAGE CONTROL

AMP02 英文数据手册DataSheet 下载
AMP02 英文数据手册DataSheet 下载

... to exceed the dynamic range of the input amplifiers. The amplified differential input signal and the input common-mode voltage must not force the amplifier’s output voltage beyond ± 12 V (VS = ± 15 V) or nonlinear operation will result. ...
Examples of Application Circuits
Examples of Application Circuits

... Since transient variations may be caused in the wiring impedance from the capacitor to the control circuit, connect the capacitor as close to the IPM control terminal and photocoupler pin as possible. Select capacitors with lower impedance and better frequency characteristics for the electrolytic ca ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... In the „end-to-end open„ test, the signal is applied to one end of each winding in turn, and the transmitted signal is measured at the other end. The magnetizing impedance of the transformer is the main parameter characterizing the low frequency response below first resonance using this configuratio ...
Technical Requirements for Subsea High Voltage Direct
Technical Requirements for Subsea High Voltage Direct

... Transmission side fault scenarios: 1. Cable ground fault 2. DC voltage short circuit fault 3. Ground fault between the stacked modules 4. Fault within the individual modules RPSEA Project 12121-6302-01, Subsea DC Connectors © 2014 General Electric Company - All rights reserved ...
SWITCHGEAR
SWITCHGEAR

... The switchgear shall be factory assembled and tested and comply with applicable industry standards. It shall be a coordinated design so that shipping groups are easily connected together at the site into a continuous line-up. Necessary connecting materials shall be furnished. All power circuit break ...
AN-600 Understanding Latch-Up in Advanced CMOS Logic AN- 600
AN-600 Understanding Latch-Up in Advanced CMOS Logic AN- 600

... signals to CMOS systems and take precautions necessary to limit the severity of over/undershoot from these sources. Measures which could be used to reduce the possibility of latch-up induced by input signals are: proper termination of transmission lines driving CMOS, series current limiting resistor ...
JU2216461651
JU2216461651

... to the reference value. The transient performance of the compensator is decided by the computation time of average load power and losses in the compensator. In most DSTATCOM applications, losses in the VSI are a fraction of the average load power. Therefore, the transient performance of the compensa ...
A Control Strategy for Hybrid Power Filter to Compensate Four
A Control Strategy for Hybrid Power Filter to Compensate Four

AZ25308314
AZ25308314

... has aggravated the power-quality (PQ) problems in the power distribution network. They cause excessive neutral currents, overheating of electrical apparatus, poor power factor, voltage distortion, high levels of neutral-to-ground voltage, and interference with communication systems [1], [2]. The lit ...
Operating Instructions
Operating Instructions

INTRODUCTION - AEP has a long tradition of technical excellence
INTRODUCTION - AEP has a long tradition of technical excellence

< 1 ... 162 163 164 165 166 167 168 169 170 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report