• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Penn Foster`s Michigan Electrical Apprenticeship program
Penn Foster`s Michigan Electrical Apprenticeship program

... safety mehods, and the use of personal protective equipment. Injuries in the workplace cost many millions of dollars in medical costs, lost wages, and production losses each year. Many injuries can be prevented by understanding how accidents and injuries can occur. This study unit is designed to hel ...
FSQ0365, FSQ0265, FSQ0165, FSQ321 Green Mode Fairchild Power Switch (FPS™)
FSQ0365, FSQ0265, FSQ0165, FSQ321 Green Mode Fairchild Power Switch (FPS™)

MAX16838 Integrated, 2-Channel, High-Brightness LED Driver with High-Voltage Boost and SEPIC Controller
MAX16838 Integrated, 2-Channel, High-Brightness LED Driver with High-Voltage Boost and SEPIC Controller

BU4S584G2
BU4S584G2

... extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our Prod ...
Zero Sequence Current Compensation for Distance
Zero Sequence Current Compensation for Distance

... adopted a variety of coping strategies in order to compensate for these effects in cases where the adjacent current is not available. However, recent experience has shown that there is another problem that must be considered when distance relays are applied to series compensated parallel lines. When ...
955 Brik Series Linear Position Sensor
955 Brik Series Linear Position Sensor

... Once the LDT has been installed, wiring connections can be made. The 955 eBrik II™ uses an industry standard 5 pin 12mm Euro style cordset with a shield, tied to the coupling nut. To reduce electrical noise, the shield must be properly used. Connect the cable’s shield to the controller system Ground ...
ADP3155 5-Bit Programmable Triple Power Supply Controller for
ADP3155 5-Bit Programmable Triple Power Supply Controller for

... then discharged at a rate determined by the off-time controller. While the timing capacitor is discharging, the low side drive output goes high, turning on the low side MOSFET. When the voltage level on the timing capacitor has discharged to the threshold voltage level VT2, comparator CMPT resets th ...
PAT-800 PAT-805
PAT-800 PAT-805

... PAT-800 and PAT-805 digital meters are used to measure the parameters of portable electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power. PAT-800 and PAT-805 can ...
APC Step-Down Transformer
APC Step-Down Transformer

B  2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection
B 2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection

... The internal gate driving circuitry of FOD8316 can be used with either a single positive power supply, VDD2, or a dual positive and negative supply, VDD2 and VSS. The output driver stage, VO, is made up of a pair of PMOS and NMOS transistors, which facilitates close to rail-to-rail output swing. Thi ...
Question Bank - International Virtual University Campus
Question Bank - International Virtual University Campus

HMC233G8
HMC233G8

... The HMC233G8 is a broadband high isolation nonreflective GaAs MESFET SPDT switch in a hermetic surface mount package. Covering DC to 6 GHz, the switch features >44 dB isolation up to 2 GHz and >31 dB isolation up to 6 GHz. The switch operates ...
Low Voltage Contact Blocks
Low Voltage Contact Blocks

... Bulletin 800E 2X PenTUFF™ low voltage contact blocks are specifically designed with the following applications in mind: • PLCs: Programmable logic controllers often communicate in low voltage DC and medium voltage AC environments between input and output devices. Push buttons that communicate with P ...
ADD8754-EVAL Evaluation Kit for LCD Power
ADD8754-EVAL Evaluation Kit for LCD Power

... Positive Charge Pump. Provides access to the positive charge pump output (VCPH) and ground. Gate Pulse Modulation. Accepts digital inputs from the timing controller (TCON) and provides a modulated VGH waveform (VGH_M). VCOM Amplifiers. Provides access to the VCOM amplifier. The potentiometer in Bloc ...
Glossary - Priority Wire
Glossary - Priority Wire

... “group potential”. By grounding at either end rather than both ends (usually grounded at source) one can reduce this interference. ...
Manual - V-TEC
Manual - V-TEC

... disabled by moving the TD jumper from one pin to both pins. This will also disable the Two-Tone sound produced normally when the Manual button is pressed while the Selector Knob (see page 9) is in the PHSR position. (see page 10 for a complete description of the Manual button) Two-Tone – (TT) A two- ...
Paralleling Arc Welding Power Sources
Paralleling Arc Welding Power Sources

... Keep cords dry, free of oil and grease, and protected from hot metal and sparks. Frequently inspect input power cord and ground conductor for damage or bare wiring – replace immediately if damaged – bare wiring can kill. Turn off all equipment when not in use. Do not use worn, damaged, undersized, o ...
DCA GENERATOR TROUBLESHOOTING GUIDE
DCA GENERATOR TROUBLESHOOTING GUIDE

... direction. The standard unit of frequency is the hertz, abbreviated Hz. If a current completes one cycle per second, then the frequency is 1 Hz; 60 cycles per second equals 60 Hz Ground Fault Interrupters (GFI's) - These devices are designed to eliminate electrical shock hazard resulting from indivi ...
Selecting a Littelfuse Varistor
Selecting a Littelfuse Varistor

... suitable for 120VAC nominal line operation and would allow for about a 120% high line condition. ...
FAN2365 TinyBuck™ 15 A Integrated Synchronous Buck Regulator F A
FAN2365 TinyBuck™ 15 A Integrated Synchronous Buck Regulator F A

V.A PJM Design and Application of Overhead Transmission Lines
V.A PJM Design and Application of Overhead Transmission Lines

... angle structures, the longitudinal direction is perpendicular to the bisector of the angle of the transmission centerline. 4.2.6. All wires intact – A condition where all intended spans of conductors and static wires are assumed to be in place. In the case of a Line Termination Structure, conductor ...
Non-electrical equipment.
Non-electrical equipment.

2. octopus system installation
2. octopus system installation

... The wire type should be audio type, minimum 24 AWG. 2. Insert the bare wires into the holes (terminal block) on the TCM located on the front of the enclosure. The probe wires have no polarity. ...
Aalborg Universitet Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems
Aalborg Universitet Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

... Transformerless photovoltaic (PV) inverters have been received more and more attention due to cost and size reduction, as well as efficiency improvement, compared with the conventional transformer ones [1-11]. A number of technical challenges may arise with increased grid-connected transformerless P ...
Fast, faster, fastest!
Fast, faster, fastest!

< 1 ... 133 134 135 136 137 138 139 140 141 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.