• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
XAPP459 - Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins on Spartan-3 Families
XAPP459 - Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins on Spartan-3 Families

... these families to handle many different single-ended signal standards. The standard singleended signaling voltage levels are 1.2V, 1.5V, 1.8V, 2.5V, and 3.3V. There are a number of applications for which it is desirable to receive signals with a greater voltage swing than User I/O pins ordinarily pe ...
Understanding And Applying The Nfpa 70e Tables Palmer Hickman
Understanding And Applying The Nfpa 70e Tables Palmer Hickman

... operating at 50 volts or more are not placed in an electrically safe work condition, other safety-related work practices shall be used to protect employees who might be exposed to the electrical hazards involved. • Such work practices shall protect each employee from arc flash and from contact with ...
evaluation of simple fault location on a mv feeder with dg
evaluation of simple fault location on a mv feeder with dg

... assumed to be known from measurements. Then the total pre-fault load can be calculated. The apparent power of the load and the DG during fault is calculated separately, using expressions similar to that given in eq. (3). NP for the DG is set to 0 (constant power characteristics). Again, this is not ...
MAX4826–MAX4831 50mA/100mA Current-Limit Switches with NO-LOAD Flag in µDFN General Description
MAX4826–MAX4831 50mA/100mA Current-Limit Switches with NO-LOAD Flag in µDFN General Description

... current limiting to prevent host devices from being damaged due to faulty load conditions. These analog switches have a low 0.7Ω on-resistance and operate from a +2.3V to +5.5V input voltage range. These devices are available with guaranteed 50mA and 100mA current limits, making them ideal for loads ...
The Dielectric Voltage Withstand Test
The Dielectric Voltage Withstand Test

... the objective of the test is only to evaluate the insulation’s electrical strength. The ...
Lab #4 Thevenin`s Theorem
Lab #4 Thevenin`s Theorem

... Lab #4 Thevenin’s Theorem In this experiment you will become familiar with one of the most important theorems in circuit analysis, Thevenin’s Theorem. Thevenin’s Theorem can be used for two purposes: 1. To calculate the current through (or voltage across) a component in any circuit, or 2. To develop ...
Voltage Harmonics Measuring Issues in Medium Voltage
Voltage Harmonics Measuring Issues in Medium Voltage

... Voltage harmonic distortion level is one of the significant parameters of power quality in power system. Numerous problems related to voltage and current harmonic effects for contemporary power systems are commonly observed nowadays. Levels and spectral content of voltage distortions injected into e ...
Power Diodes Characteristics Power Diode
Power Diodes Characteristics Power Diode

— mWSaver™ PWM Controller FAN6757 FAN 6
— mWSaver™ PWM Controller FAN6757 FAN 6

62-0395_B - H Series Class 100 Meter Installation
62-0395_B - H Series Class 100 Meter Installation

... Internal circuit card components are extremely sensitive to electrostatic discharge. Prior to handling or touching internal circuitry, discharge any static buildup on your person. To discharge yourself, touch a grounded metal object such as conduit or an earth grounded+ metal enclosure. ...
FSB50660SFS Motion SPM 5 SuperFET Series
FSB50660SFS Motion SPM 5 SuperFET Series

STP 3 & 4 8.3  Onsite Power Systems
STP 3 & 4 8.3 Onsite Power Systems

... The design minimizes the probability of a single failure affecting more than one FMCRD group by providing three six independent Class 1E feeds (one two for each group) directly from the Division I Class 1E 6.9 k and PIP 480V buses (see sheet 3 and 4 of Figure 8.3-1). The two Class 1E protective devi ...
Comparative Analysis of CMOS OTA
Comparative Analysis of CMOS OTA

... produces an output current and hence it is a voltage controlled current source (VCCS). There is usually an additional input for a current to control the amplifier's trans-conductance. The OTA is similar to a standard Operational Amplifier in that it has a high impedance differential input stage and ...
Comprehensive Study of Forward and Fly Back Converter for
Comprehensive Study of Forward and Fly Back Converter for

... that when fly back converter operates independently. They can achieve better power factor with lower conversion efficiency whereas forward converter can able to achieve higher efficiency but having larger magnetizing offset current. Also has higher voltage stress. This entire problem can be overcome ...
Low impedance package for integrated circuit die
Low impedance package for integrated circuit die

... each 10° C. increase in operating temperature. For more complex chips such as a microprocessor in ...
BD35390FJ
BD35390FJ

... Ensure that no pins are at a voltage below that of the ground pin at any time, even during transient condition. 4. Ground Wiring Pattern When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference p ...
Common AC Power Distribution Configurations
Common AC Power Distribution Configurations

... Email : [email protected] Email : [email protected] ...
Medium Voltage Power System Maintenance
Medium Voltage Power System Maintenance

... For each liquid filled transformer, provide one (1) test sheet summarizing and commenting on chemical and gas est results. Compare results with previous tests. ...
A Switched-Capacitor DC–DC Converter With High Voltage Gain
A Switched-Capacitor DC–DC Converter With High Voltage Gain

Instruction Manual
Instruction Manual

... The difference between the voltage settings for two or more power supplies of the same model connected in parallel should not exceed 15V. The minimum voltage setting should not be less than 10V. If it is necessary to be lower than 10V, the voltage difference should be less than 2V. The closer to 0V, ...
HP ProLiant SL Server Site Planning Guide
HP ProLiant SL Server Site Planning Guide

Power Quality Issues, Disturbance Sources, Financial Impacts
Power Quality Issues, Disturbance Sources, Financial Impacts

... The semiconductor industry developed a more recent specification (SEMI F47) for tools used in the semiconductor industry in an effort to achieve better ride through of equipment for commonly occurring voltage dips and therefore improving the overall process performance. It is basically the same as t ...
Solid-State Relays Current Limit Performance
Solid-State Relays Current Limit Performance

... VISHAY SSR WITH CURRENT LIMIT 1. The current-limt SSR draws a short pulse of current, indistinguishable on this millisecond scale 2. The current-limit SSR turns itself off during the worst part of the impulse wave dissipating no power 3. The current-limit SSR turns itself back on into current limiti ...
Zener Diodes
Zener Diodes

Coil on Plug: The Wired Differences
Coil on Plug: The Wired Differences

... 1. Remove only low reference: runs fine 2. Remove only chassis ground: runs fine 3. Remove both chassis ground and low reference: runs fine Indicating ability to ground coil electronics through eyelet bolt ground if necessary ...
< 1 ... 130 131 132 133 134 135 136 137 138 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report