• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A

... microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power Powering a water supply pump A water well or pressure pump often places the greatest demand on the inverter. It warrants special considera ...
FSBB15CH60 Motion SPM 3 Series FSBB15CH60  Motion SPM® 3 Series
FSBB15CH60 Motion SPM 3 Series FSBB15CH60 Motion SPM® 3 Series

... 5. VFO output pulse width should be determined by connecting an external capacitor (CFOD) between CFOD (pin 7) and COM (pin 2). (Example : if CFOD = 33 nF, then tFO = ms (typ.)) Please refer to the 2nd note 5 for calculation method. 6. Input signal is active-HIGH type. There is a 3.3 kresistor ...
BU7481G
BU7481G

... (Note 3) The voltage difference between inverting input and non-inverting input is the differential input voltage. Then input pin voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input curr ...
Electrical Design for Roadside Devices
Electrical Design for Roadside Devices

... Voltage drop ................................................................................................................ 11 ...
An introduction to Inverters and Applications
An introduction to Inverters and Applications

MO-201 Electric Power Distribution Systems
MO-201 Electric Power Distribution Systems

Linear Systems replaces discontinued Siliconix 2N4391
Linear Systems replaces discontinued Siliconix 2N4391

... VGS = 0V,   ID = 1mA  2N4391 DYNAMIC ELECTRICAL CHARACTERISTICS @ 25°C (unless otherwise noted)  SYMBOL  CHARACTERISTIC  TYP  MIN  MAX  UNITS  CONDITIONS  The 2N4391 features many of the superior characteristics of JFETs which make it a good choice for demanding analog switching applications and for ...
AP6015
AP6015

... The AP6015 is the first device in a family of low-noise current mode synchronous step-down DC-DC converters. It is ideally suited for systems powered by either a 1-cell Li-ion battery or a 2to 3-cell NiCd/ NiMH/ Alkaline battery. The AP6015 is a synchronous PWM converter with integrated N- and P-cha ...
AND8461/D Design of a 65 W Adapter Utilizing the NCP1237 PWM Controller
AND8461/D Design of a 65 W Adapter Utilizing the NCP1237 PWM Controller

... transient peak power timer duration time (typ 156 ms). It allows using the NCP1237/87 with the peak power protection in the printer adapters which can deliver 2 times higher peak power than the maximum output power from the thermal loading point of view. The whole family of controllers NCP1237/38/87 ...
seismometers calibration: comparison between a relative
seismometers calibration: comparison between a relative

... phenomenon of the solenoid coils are the main contributors [5][6]. In an ideal system with no capacitor coupling between the coils and in the coils the calibration coil produces a current, and the induced electromagnetic force moves the arms and the measuring coil which induced the output signal wha ...
SEMI STEP: Introduction to SEMI S2-0706
SEMI STEP: Introduction to SEMI S2-0706

EMI/RFI Suppression Capacitors
EMI/RFI Suppression Capacitors

... EMI suppression capacitors are used to suppress any noise from an electronic device by reducing the input impedance of the device. These capacitors are divided into 2 classifications, X and Y. X class capacitors are capacitors that are connected line to line and in the event of failure of the capaci ...
Switch-on-to-Fault Schemes in the Context of Line Relay
Switch-on-to-Fault Schemes in the Context of Line Relay

... settings, there may be implications for line relay loadability. This paper addresses those implications in the context of scheme design. ...
MAX17498A/MAX17498B/MAX17498C AC-DC and DC
MAX17498A/MAX17498B/MAX17498C AC-DC and DC

... greater than 92% and provide programmable slope compensation to allow optimization of control loop performance. The devices provide an open-drain PGOOD pin that serves as a power-good indicator and enters the high-impedance state to indicate that the flyback /boost converter is in regulation. An SS ...
The Electrical Code Committee has been asked to convene for
The Electrical Code Committee has been asked to convene for

... homes have many additional loads that were not anticipated in the past, and may cause significant additional loading. This requirement limits the loading risk on any particular circuit. This geographical area has a high ambient temperature, and circuits are often run through attics where the high he ...
Course Notes
Course Notes

THE TRANSMISSION LINE COST CALCULATION  Juho Yli-Hannuksela
THE TRANSMISSION LINE COST CALCULATION Juho Yli-Hannuksela

... Table 1. Comparison of the conductors and tower ............................................... 23 Table 2. Explanation of the acronyms for table 4 ................................................. 23 Table 3. Power model for 72.5 kV .................................................................. ...
performance analysis of multilevel inverter with spwm strategy using
performance analysis of multilevel inverter with spwm strategy using

... sharing between S1’and S2’ with S1’ blocking the voltage across C1 and S2’ blocking the voltage across C2. Notice that output voltage van is ac, and vao is dc. The difference between van and vao is the voltage across C2, which is Vdc/2. If the output is removed out between a and 0, then the circuit ...
Report on Frequent Tripping of Pragati GT (FEB-2010)
Report on Frequent Tripping of Pragati GT (FEB-2010)

... Pragati unit #2 was erratic and this unit trips now and then, where as other GTs connected to the system do not have such behavior. On earlier occasions also, this Gas Turbine of Pragati Power Corporation Ltd. tripped during the time of disturbances elsewhere in the network. Protection Sub. Committe ...
P83566
P83566

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
Pignose G40V 40w Tube Amp
Pignose G40V 40w Tube Amp

... run to the preamp star ground point. I could have alternately run the wire to the ground pad on the circuit board or added a solder terminal to a 4x40 screw and nut that would replace the sheet metal screw holding down one end of the tube socket. I dabbed some clear silicone on the caps to keep them ...
FSBB15CH60F Motion SPM 3 Series FSBB15CH60F  Motion SPM® 3 Series
FSBB15CH60F Motion SPM 3 Series FSBB15CH60F Motion SPM® 3 Series

STP 3 & 4 8.3  Onsite Power Systems
STP 3 & 4 8.3 Onsite Power Systems

... diesel bus source. Switching back to the Class 1E diesel bus power is by manual action only. Per IEEE-384 and Regulatory Guide 1.75, isolation between the Class 1E bus and non-1E load is maintained. STD DEP 8.3-1 STP DEP 8.3-3 The design minimizes the probability of a single failure affecting more t ...
Inductive and Capacitive Reactance
Inductive and Capacitive Reactance

... At the beginning of the first quarter-cycle (0º to 90º) the voltage has just passed through zero and is increasing in the positive direction. Since the zero point is the steepest part of the sine wave, the voltage is changing at its greatest rate. The charge on a capacitor varies directly with the ...
MAX8752 TFT LCD Step-Up DC-DC Converter General Description Features
MAX8752 TFT LCD Step-Up DC-DC Converter General Description Features

... The MAX8752 is a highly efficient, step-up power supply designed for TFT-LCD panels. The typical circuit shown in Figure 1 operates from an input voltage as low as 1.8V, and produces a MAIN output of 10V at 220mA from 2.5V input while supporting discrete diode-capacitor charge pumps that produce -9V ...
< 1 ... 127 128 129 130 131 132 133 134 135 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report