• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A 93% efficient LED driver solution for the US market
A 93% efficient LED driver solution for the US market

... A DC reference voltage is derived from U1’s inverting input. This point will always be at 2.5 V if the control loop is in steady-state, because there is no DC current path to any other voltage source. The reference voltage is delivered to U2’s inverting input by divider R18R21. The voltage divider R ...
LTC4355 Positive High Voltage Ideal Diode
LTC4355 Positive High Voltage Ideal Diode

B25667C4307A375
B25667C4307A375

... before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of ...
TDA1085C Universal Motor Speed Controller
TDA1085C Universal Motor Speed Controller

... which concerns the group of sensitive Pins and their associated capacitors into which the a.m. rules have been implemented. Notice the full separation of “Signal World” from “Power”, one by line AB and their communication by a unique strip. These rules will lead to much satisfactory volume productio ...
Complete Paper
Complete Paper

... Abstract—Power and area will remain the main constraints in the designing of VLSI circuits. Dynamic CMOS logic circuits are broadly designed for high performance circuits due to their high speed. Conversely, the demerit of dynamic logic style is its high noise sensitivity. The main cause of this is ...
Wide Input Voltage, Eco-mode™, Single
Wide Input Voltage, Eco-mode™, Single

... 0.6 V to 5.5 V. The conversion input voltage range is from 3 V up to 28V. The D-CAP™ mode uses the ESR of the output capacitor(s) to sense the device current . One advantage of this control scheme is that it does not require an external phase compensation network. This allows a simple design with a ...
LTC4355 Positive High Voltage Ideal Diode
LTC4355 Positive High Voltage Ideal Diode

... supply, excessive MOSFET current due to overcurrent on the load or a shorted MOSFET on the lower supply. During startup or when a switchover between supplies occurs, the VDSFLT pin and PWRFLT1 or PWRFLT2 pin may momentarily indicate that the forward voltage has exceeded the programmed threshold duri ...
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of

... ease of obtaining spare parts, and therefore lead to a ...
Standard: Substation Installation Technical
Standard: Substation Installation Technical

... Applicable to Customer’s main switchboard location with respect to a Substation. Contiguous means adjoining or very close to the Substation enclosure to ensure that cable/s connecting the substation equipment to the main switchboard has zero probability of being damaged with consequent risk to safet ...
MAX9940 - Maxim Integrated
MAX9940 - Maxim Integrated

THE SOLLATEK VOLTAGE STABILISER (SVS) RANGE
THE SOLLATEK VOLTAGE STABILISER (SVS) RANGE

... TimeSave™. TimeSave™ means that when the mains return to normal from a brownout, the SVS checks the duration of the OFF time. For example for models that have 3 minute delay; If the unit has been off for more than 3 minutes then it will reconnect the mains within 30 seconds rather than the standard ...
LAB 5 Capacitors
LAB 5 Capacitors

... To measure the voltage across an initially uncharged capacitor, use the following procedure: • Connect a 0.05 µF capacitor to a 10V power supply and charge it up (one or two seconds). Disconnect the power supply from the capacitor and be careful not to touch either side of the capacitor or you will ...
SLIC Devices
SLIC Devices

... lines and equations describing all regions of operation are provided in each device data sheet. To obtain polarity reversal, the input decoder and control circuit send a signal that reverses the sign of the voltage on the RDC pin. During reversal, sense resistors R HP are shunted to reduce the time ...
Dynamic Characteristics of Mho Distance Relays
Dynamic Characteristics of Mho Distance Relays

... condition than it does steady-state, and it does not operate under either dynamic or steady-state conditions. (2) Load Flow in Tripping Direction Fig. 16 shows the effect of load flow in the tripping direction, using the same system conditions as in Fig. 10. Consider the R1 relay and the F4 fault l ...
Alberta Reliability standard Transmission Relay Loadability PRC-023-AB-2
Alberta Reliability standard Transmission Relay Loadability PRC-023-AB-2

... September 6November 15, 2012 1. Purpose The purpose of this reliability standard is to ensure the protective relay settings do not limit transmission loadability, do not interfere with an operator’s ability to take remedial action to protect the reliability of the system, and are set to reliably det ...
B25667C3297A375
B25667C3297A375

... before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of ...
Coil On Plug Ignition: The Wired Differences - OpenSIUC
Coil On Plug Ignition: The Wired Differences - OpenSIUC

... 1. Remove only low reference: runs fine 2. Remove only chassis ground: runs fine 3. Remove both chassis ground and low reference: runs fine Indicating ability to ground coil electronics through eyelet bolt ground if necessary ...
Power Supply Installation
Power Supply Installation

... This chapter describes how to remove and install a new or replacement power supply. Your switch ships with at least one installed power-supply module (AC or DC, depending on your order). The power-supply modules are field-replaceable units (FRUs) and are hot-swappable. For translations of the safety ...
B25667C3247A375
B25667C3247A375

... before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of ...
electronic components - Crompton Instruments
electronic components - Crompton Instruments

... drop, typically 0.3 volts; this low forward voltage drop results in a low power loss and more efficient diode, making it superior in many ways to the silicon diode. A silicon diode forward voltage drop, by comparison, is typically 0.7 volts. This lower voltage drop with germanium becomes important i ...
Film Capacitors – Power Factor Correction
Film Capacitors – Power Factor Correction

... before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of ...
Film Capacitors – Power Factor Correction
Film Capacitors – Power Factor Correction

... before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of ...
Amphenol AIB/GT Series MIL-DTL-5015 - PEI
Amphenol AIB/GT Series MIL-DTL-5015 - PEI

BH12PB1WHFV
BH12PB1WHFV

... Use caution when positioning the IC for mounting on printed circuit boards. The IC may be damaged if there is any connection error or if pins are shorted together. 4. Thermal shutdown circuit (TSD) The IC incorporates a built-in thermal shutdown circuit (TSD circuit). The thermal shutdown circuit is ...
FUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE
FUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE

< 1 ... 123 124 125 126 127 128 129 130 131 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.