Time-Varying and Probabilistic Considerations: Setting Limits
... Figure 10.2 shows a histogram and cumulative distribution function for a typical harmonic voltage measurement, in this case, for a week long measurement. While this data yields information on the time duration at a given distortion level, it does not contain information on the duration of individual ...
... Figure 10.2 shows a histogram and cumulative distribution function for a typical harmonic voltage measurement, in this case, for a week long measurement. While this data yields information on the time duration at a given distortion level, it does not contain information on the duration of individual ...
Evaluates: MAX15039 MAX15039 Evaluation Kit General Description Features
... 24-pin TQFN surface-mount package with an exposed pad. Applications include enterprise-server, telecommunication, computing, and networking power supplies. The EV kit generates selectable output voltages from 0.6V to 2.5V at load currents up to 6A. The output voltage should be configured only BEFORE ...
... 24-pin TQFN surface-mount package with an exposed pad. Applications include enterprise-server, telecommunication, computing, and networking power supplies. The EV kit generates selectable output voltages from 0.6V to 2.5V at load currents up to 6A. The output voltage should be configured only BEFORE ...
HMC597LP4 数据资料DataSheet下载
... The circuit board used in the final application should use RF circuit design techniques. Signal lines should have 50 ohm impedance while the package ground leads and exposed paddle should be connected directly to the ground plane similar to that shown. A sufficient number of via holes should be used ...
... The circuit board used in the final application should use RF circuit design techniques. Signal lines should have 50 ohm impedance while the package ground leads and exposed paddle should be connected directly to the ground plane similar to that shown. A sufficient number of via holes should be used ...
FPF2193 / FPF2194 / FPF2195 Full
... Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be operable above the recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure to stresses above the recommended operating conditi ...
... Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be operable above the recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure to stresses above the recommended operating conditi ...
Optimal Voltage Regulators Placement in Radial Distribution System
... Let the initial voltage regulators are located at buses 8, 11, 13 and 18 as shown in Fig.2 It is proposed to reduce the number of VRs in a practical system by shifting the VR’s to the junction of laterals (such as from buses 11 and 13 to bus 10) and observe the voltage profile and the objective func ...
... Let the initial voltage regulators are located at buses 8, 11, 13 and 18 as shown in Fig.2 It is proposed to reduce the number of VRs in a practical system by shifting the VR’s to the junction of laterals (such as from buses 11 and 13 to bus 10) and observe the voltage profile and the objective func ...
BD82022FVJ
... Pull up /OC output via resistance value of 10kΩ to 100kΩ. Set up a value for CL which satisfies the application. This system connection diagram does not guarantee operation as the intended application. When using the circuit with changes to the external circuit values, make sure to leave an adequate ...
... Pull up /OC output via resistance value of 10kΩ to 100kΩ. Set up a value for CL which satisfies the application. This system connection diagram does not guarantee operation as the intended application. When using the circuit with changes to the external circuit values, make sure to leave an adequate ...
2SP0115T Preliminary Description & Application Manual
... Even if only single IGBTs are tested, all the system’s gate drivers must be supplied with energy. All the other IGBTs are then kept in the off state by applying negative gate voltages. This is particularly important when switching the IGBTs under test. The short-circuit behavior can also be verified ...
... Even if only single IGBTs are tested, all the system’s gate drivers must be supplied with energy. All the other IGBTs are then kept in the off state by applying negative gate voltages. This is particularly important when switching the IGBTs under test. The short-circuit behavior can also be verified ...
MN1919WEN MicroFlex
... Unless otherwise specified, this drive is intended for installation in a suitable enclosure. The enclosure must protect the drive from exposure to excessive or corrosive moisture, dust and dirt or abnormal ambient temperatures. The exact operating specifications are found in section 8 of this manual ...
... Unless otherwise specified, this drive is intended for installation in a suitable enclosure. The enclosure must protect the drive from exposure to excessive or corrosive moisture, dust and dirt or abnormal ambient temperatures. The exact operating specifications are found in section 8 of this manual ...
Technical report
... - RD is the risk due to flashes striking the structure - RI is the risk due to flashes influencing it but not striking the structure - RS is the risk due to injury to livings beings - RF is the risk due to physical damage - RO is the risk due to failure of internal systems. The values listed above, ...
... - RD is the risk due to flashes striking the structure - RI is the risk due to flashes influencing it but not striking the structure - RS is the risk due to injury to livings beings - RF is the risk due to physical damage - RO is the risk due to failure of internal systems. The values listed above, ...
Project P917 - EURESCOM Home Page
... powering over the existing telecom cables and /or local AC powering with battery backup. The drawback of these solutions is that they can either supply low power for an extended period of time (remote feeding through existing copper cables) or they can deliver high power for a limited backup time pe ...
... powering over the existing telecom cables and /or local AC powering with battery backup. The drawback of these solutions is that they can either supply low power for an extended period of time (remote feeding through existing copper cables) or they can deliver high power for a limited backup time pe ...
Design and Implementation of Dynamic Voltage Restorer for Voltage Sag Mitigation
... problems like voltage sag, harmonic and flicker, interruptions, harmonic distortion. Preventing such phenomena is particularly important because of the increasing heavy automation in almost all the industrial processes. High quality in the power supply is needed, since failures due to such disturban ...
... problems like voltage sag, harmonic and flicker, interruptions, harmonic distortion. Preventing such phenomena is particularly important because of the increasing heavy automation in almost all the industrial processes. High quality in the power supply is needed, since failures due to such disturban ...
Unit 38 AC Installation
... • Piping is connected to the condensing unit from the evaporator • Units must be able to be serviced properly • Units should be set on pads • Condensing units should be located in the shade • Noise should not be objectionable ...
... • Piping is connected to the condensing unit from the evaporator • Units must be able to be serviced properly • Units should be set on pads • Condensing units should be located in the shade • Noise should not be objectionable ...
Pulsing a Laser Diode
... The purpose of the following experiments is to show the effects of mismatch and stray reactance on pulse waveforms when driving a laser diode. For each test configuration, the diode pulse and resultant light output are recorded to show the change in pulse waveforms caused by modifications to the test ...
... The purpose of the following experiments is to show the effects of mismatch and stray reactance on pulse waveforms when driving a laser diode. For each test configuration, the diode pulse and resultant light output are recorded to show the change in pulse waveforms caused by modifications to the test ...
Wiring Manual | 2011
... breakers certified per the UL 489 product standard, and those found in Industrial Control, typically falling under UL 508. Product standards such as UL 489 and CSA C22.2 No. 5-09 require significantly larger air and creepage clearances in component construction than do the IEC standards and their ha ...
... breakers certified per the UL 489 product standard, and those found in Industrial Control, typically falling under UL 508. Product standards such as UL 489 and CSA C22.2 No. 5-09 require significantly larger air and creepage clearances in component construction than do the IEC standards and their ha ...
Reducing EMI in buck converters
... The input supply for the converter is provided by a 3S (~12V) Li-Ion battery, to be independent of other lab equipment. There is an electrolytic capacitor across the battery leads to eliminate resonances due to battery inductance. The converter load is a 1Ω resistor in parallel with a 10µF MLCC capa ...
... The input supply for the converter is provided by a 3S (~12V) Li-Ion battery, to be independent of other lab equipment. There is an electrolytic capacitor across the battery leads to eliminate resonances due to battery inductance. The converter load is a 1Ω resistor in parallel with a 10µF MLCC capa ...
LTC5542 - 1.6GHz to 2.7GHz High Dynamic Range Downconverting Mixer.
... pin may require a bypass capacitor to ground. See the Applications Information section. This pin has an internally generated bias voltage of 1.2V. It must be DC-isolated from ground and VCC. GND (Pins 4, 10, 12, 13, 17, Exposed Pad Pin 21): Ground. These pins must be soldered to the RF ground plane ...
... pin may require a bypass capacitor to ground. See the Applications Information section. This pin has an internally generated bias voltage of 1.2V. It must be DC-isolated from ground and VCC. GND (Pins 4, 10, 12, 13, 17, Exposed Pad Pin 21): Ground. These pins must be soldered to the RF ground plane ...
Mini Buck Converters for RF Power Amplifiers
... on time is kept constant and the switching frequency is variable. Output voltage is regulated by varying the switching frequency which becomes proportional to loading current. As it does in PWM mode, the internal N−MOSFET operates as synchronous rectifier after each P−MOSFET on−pulse. When load incr ...
... on time is kept constant and the switching frequency is variable. Output voltage is regulated by varying the switching frequency which becomes proportional to loading current. As it does in PWM mode, the internal N−MOSFET operates as synchronous rectifier after each P−MOSFET on−pulse. When load incr ...
ELECTRONIC BALLAST NIK MUHAMMAD FASHAN BIN HUSAIN
... even more current to flow. Connected directly to a constant-voltage mains power line, a fluorescent lamp would rapidly self-destruct due to the uncontrolled current flow. To prevent this, fluorescent lamps must use an auxiliary device, commonly called a ballast, to regulate the current flow through ...
... even more current to flow. Connected directly to a constant-voltage mains power line, a fluorescent lamp would rapidly self-destruct due to the uncontrolled current flow. To prevent this, fluorescent lamps must use an auxiliary device, commonly called a ballast, to regulate the current flow through ...
070000009 8270 Electrical Manual
... between the other two wires is 230, while half of this voltage (115) appears between each of these wires and neutral. In this system, pinspotter load is divided between the two sides of the circuit, half the pinspotters in the center being connected between one wire and the neutral, while the other ...
... between the other two wires is 230, while half of this voltage (115) appears between each of these wires and neutral. In this system, pinspotter load is divided between the two sides of the circuit, half the pinspotters in the center being connected between one wire and the neutral, while the other ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.