• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
7.3 Location by Separation of Electrodes (cont.)
7.3 Location by Separation of Electrodes (cont.)

... In one case, an overlap is created in the low-voltage electrode; this must be made carefully so that no discharge arise in the separation itself ...
Text for specifiers - Industrial Solutions
Text for specifiers - Industrial Solutions

... securely interrupt and as such is a disconnect switch. This, together with the high short-circuit resistance and the visible contact status, makes it possible to use this switch as a main switch, - The housing is made of thermoplastic material with a high creepage-current resistance - The movable co ...
Evaluation Board User Guide UG-116
Evaluation Board User Guide UG-116

Advanced Protection Technologies
Advanced Protection Technologies

... Reason: Avoid installation & AHJ headaches because Type 1’s can be installed ‘anywhere’. Type 1’s are more rigidly evaluated per UL & NEC for installation on line side of Main Disconnect. This means that internal overcurrent protection is included & tested within SPD and wires are tested too. 1.) Th ...
Keyword: [GND Clamp Reference]
Keyword: [GND Clamp Reference]

... Clamp] structures are “Vcc relative”, meaning that the voltage values are referenced to the Vcc pin. (Note that, under these keywords, all references to “Vcc” refer to the voltage rail defined by the [Voltage Range], [Pullup Reference], or [POWER Clamp Reference] keywords, as appropriate.) The volta ...
- UTas ePrints
- UTas ePrints

ECM Diagnosis
ECM Diagnosis

... BATT terminal of the ECM. Battery voltage is supplied to the BATT terminal even when the ignition switch is OFF. The ECM uses this power for memory and adaptive memory values such as A/F Ratio control. If DTC P1600 is displayed, the ECM does not store another DTC. The BATT circuit must be checked an ...
133-08AY08(circ1)
133-08AY08(circ1)

... Let's test this by building a circuit. We will measure the current flow on both sides of a light bulb, as suggested in the models above. Build the circuit shown below. You will need a switch, battery, light bulb, two current probes, and several alligator clip leads (wires). A current probe measures ...
MAX16803 High-Voltage, 350mA, High-Brightness LED Driver with PWM Dimming and 5V Regulator
MAX16803 High-Voltage, 350mA, High-Brightness LED Driver with PWM Dimming and 5V Regulator

Reusing and Rerating Older Rectifiers with New DC/DC
Reusing and Rerating Older Rectifiers with New DC/DC

... application for reusing and rerating using a chopper. A diode rectifier without saturable reactor phase control would be ideal. If reactors are used, they must be configured to have a minimum effect on the system. If feasible, the reactors can be removed. 2) Thyristor Rectifiers: These can also be u ...
PAM2846 Description Pin Assignments
PAM2846 Description Pin Assignments

$doc.title

Hola Agustin - Portal UniMAP
Hola Agustin - Portal UniMAP

... transformer represented in Fig 2-7, with the load switch open, a small current called the exciting current flows. As in any inductive circuit, the current is limited by the counter emf of self-induction that is induced in the winding. Transformer windings are designed to have an inductance high enou ...
BD9G101G
BD9G101G

... TSZ02201-0Q1Q0AJ00150-1-2 04.MAR.2014 Rev.004 ...
Uninterruptible Power Supplies (UPS)
Uninterruptible Power Supplies (UPS)

... The advantages of installing a Surge Protective Device (SPD) on a facility's service entrance are well documented and acknowledged as being essential in protecting sensitive electronic equipment from outside sources of transient voltages such as lightning strikes and utility company switching. For s ...
LIGHTNING IMPULSE TESTS ON AIR
LIGHTNING IMPULSE TESTS ON AIR

... In the past several decades, extensive amount of research work has been done to understand the fundamental characteristics of the electrical breakdown. Breakdown voltage is a phenomenon where the quantity of an electrical force is required to transform the electrical properties of an object. Many fa ...
Therefore, the phase fault currents are - Sacramento
Therefore, the phase fault currents are - Sacramento

... substation in order to see how the system will react during abnormal operating ...
Caterpillar Generator AVR VR6,K65-12B,K125-10B
Caterpillar Generator AVR VR6,K65-12B,K125-10B

... procedure, practice, condition, or statement that, if not strictly followed, could result in death or serious injury to personnel. Caution: Cautions identify an installation, operating or maintenance procedure, practice, condition, or statement that, if not strictly followed, could result in destruc ...
Paper Title (use style: paper title) - American Journal of Engineering
Paper Title (use style: paper title) - American Journal of Engineering

... applications, the modified comparator is designed based on the double tail structure. The main idea of the modified comparator is to reduce the static power consumption by completely cutoff the flow of leakage current to the ground. For this purpose, two more switching transistors (MSW3 and MSW4) ha ...
AD694 - Analog Devices
AD694 - Analog Devices

... in high levels of accuracy without the need for additional adjustments and calibration. An external pass transistor may be used with the AD694 to off-load power dissipation, extending the temperature range of operation. The AD694 is the ideal building block for systems requiring noise immune 4–20 mA ...
Circuit models for a..
Circuit models for a..

... Let’s say on the EECS 412 final, I ask you to determine Vout in the circuit above. ...
The Secrets of UL and NFPA. - Automation Technology
The Secrets of UL and NFPA. - Automation Technology

... with the UL know-how by Siemens • You can depend on our strong and reliable product and system portfolio, which have been designed with consideration to the UL standards right from the development phase. • Save commissioning time with expert UL consulting services and training courses. • Obtain assi ...
App58-Solid State Relays Current Limit Performance
App58-Solid State Relays Current Limit Performance

... state. If an MOV protection device is used, it sets the maximum voltage that is imposed on the SSR and shunts some of the current around the SSR when its zener voltage is exceeded. The SSR remains in this state until the transient subsides. At this time, the SSR immediately resumes its normal operat ...
MC34653, 1.0 A Negative Voltage Hot Swap Controller
MC34653, 1.0 A Negative Voltage Hot Swap Controller

... voltage required for the internal circuitry. The Power MOSFET will stay off until the start of the charging process. After the Power-ON Reset (POR) and once the Undervoltage Lockout (UVLO) threshold is cleared, the 34653 checks for external components on two pins — ILIM and ICHG —to set the levels o ...
Lesson C3-1:
Lesson C3-1:

... from other lighting techniques or it can use direct methods involving actual fixtures installed along the walkway or path (sometimes called contour lighting). Safety lighting is sometimes activated by photocells (light sensitive switches that automatically turn lights on at dusk and off at sunrise). ...
< 1 ... 114 115 116 117 118 119 120 121 122 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report