• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electronics Tutorial about the Types of Resistors The Different Types
Electronics Tutorial about the Types of Resistors The Different Types

... Another type of resistor, called a Wirewound Resistor, is made by winding a thin metal alloy wire (Nichrome) or similar wire onto an insulating ceramic former in the form of a spiral helix similar to the film resistor above. These types of resistors are generally only available in very low ohmic hig ...
16972 - Electrical Starting and Testing by Contractor`s Testing Agent
16972 - Electrical Starting and Testing by Contractor`s Testing Agent

... Check all control, relaying and instrumentation wiring against vendor wiring schematics, three line diagrams and project specifications. ...
TNB Technical Guidebook on Grid-interconnection of Photovoltaic
TNB Technical Guidebook on Grid-interconnection of Photovoltaic

... practical means of energy generation in Malaysia. However it must be noted that, especially for large-scale PV, caution needs to be taken as to its impact on the distribution network it is connected to. With higher penetration of PV, meaning a higher ratio of PV power injection compared to loading, ...
Arc Welding
Arc Welding

... continuous conscious effort by the welder over a long period. Many of these aspects will soon become a natural reflex action or habit with practice. So learn good habits, not bad habits. Striking the Arc (Are you wearing suitable clothing, gloves, etc., and have you checked the area for fire hazard ...
TPS7B4250-Q1 Pin FMEA
TPS7B4250-Q1 Pin FMEA

... anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components ...
FAULT DIAGNOSIS AND DETECTION IN POWER SYSTEMS
FAULT DIAGNOSIS AND DETECTION IN POWER SYSTEMS

... Breakers (SSB), to be used as interface between the electrical utility system and the private generating system with sensitive loads, ‘intelligently’ controlled by artificial neural networks. They are software routines running on fast computers which play nowadays an important role in solving Power ...
Complex Circuits I 0.9
Complex Circuits I 0.9

Water/Sewer/Drainage Electrical Specifications
Water/Sewer/Drainage Electrical Specifications

... One end of the kiosk will be used to accommodate motor and control connections. Access to this area will be a lockable hinged door. The explosion-proof isolation will occur at this point between this area and the remainder of the kiosk area (cables will be routed through the ground to this area, not ...
AT120A, AT140A, AT150A, AT175A Universal
AT120A, AT140A, AT150A, AT175A Universal

Three-input Type Single Chip Inverter IC Application Note 【Rev 0】
Three-input Type Single Chip Inverter IC Application Note 【Rev 0】

... When the 15V_VCC voltage goes below the LVSD operating voltage (LVSDON), the output IGBTs of the top and bottom arms are all turned off regardless of the input signal. This function has hysteresis (Vrh). When the 15V_VCC voltage goes up again, the system returns to a state in which the ouput IGBT op ...
User's Manual PQP-A Energotester  Edition 1
User's Manual PQP-A Energotester Edition 1

... ƒ For voltage and current meters as well as active, reactive and apparent power meters: in-situ control of their performance and connection check; ƒ For single- and three-phase electric energy meters: control of their performance and connection check without breaking into current circuits; ƒ Measure ...
PAM2842 Description Pin Assignments
PAM2842 Description Pin Assignments

... Frequency <100Hz can cause the LEDs to blink visibly. As the COMP pin connects to a capacitor, it needs rise time. If frequency >200Hz, the average LED current will have a large error when duty cycle is small (<50%). It maybe generate the audible noise in this dimming condition. ...
MAX5911/MAX5912 -48V Simple Swapper Hot-Swap Switches General Description Features
MAX5911/MAX5912 -48V Simple Swapper Hot-Swap Switches General Description Features

... the safe insertion and removal of circuit cards into live backplanes or ports without causing problematic glitches on the negative power-supply rail. They also monitor various circuit parameters and disconnect the load if a fault condition occurs, alerting the host with a logic-level FAULT output. T ...
LM3489/LM3489Q Hysteretic PFET Buck Controller with Enable Pin
LM3489/LM3489Q Hysteretic PFET Buck Controller with Enable Pin

... device is intended to be functional, but device parameter specifications may not be ensured. For specifications and test conditions, see the Electrical Characteristics. This pin is internally pulled high and clamped at 8V typical. The absolute maximum and operating maximum rating specifies the input ...
An article for ozvalveamps on renovating PA amps
An article for ozvalveamps on renovating PA amps

... effective plate supply resistance and a given filter capacitor size. If the amp is operating with a lower supply voltage, lower load current, lower output capacitance, and higher supply resistance, then using that valve diode is fine. If your plate supply resistance is lower than rated, or you want ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
Liebert Series 610 UPS DISCONTINUED PRODUCT

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
MAX5930/MAX5931 Low-Voltage, Triple, Hot-Swap Controllers/ Power Sequencers/Voltage Trackers General Description
MAX5930/MAX5931 Low-Voltage, Triple, Hot-Swap Controllers/ Power Sequencers/Voltage Trackers General Description

FSB50550A / FSB50550AT Motion SPM 5 Series ®
FSB50550A / FSB50550AT Motion SPM 5 Series ®

... 1. BVDSS is the absolute maximum voltage rating between drain and source terminal of each MOSFET inside Motion SPM® 5 product. VPN should be sufficiently less than this value considering the effect of the stray inductance so that VPN should not exceed BVDSS in any case. 2. tON and tOFF include the p ...
coinshooter
coinshooter

... coil from the form. Spiral-wrap the coil tightly with masking tape. Wrap the coil with foil and another layer of tape as on L1 and L2 being sure to cover the foil completely. If the two foil shields are allowed to touch when the coils are positioned, the detector will not function. Now assemble the ...
AN1625
AN1625

... Both bulk electrolytic and high frequency bypass capacitors have to be connected with short tracks to VSA, VSB and GND. On the L6235 GND pins are the Logic GND, since only the quiescent current flows through them. Logic GND and Power GND should be connected together in a single point, the bulk capac ...
Time-Varying and Probabilistic Considerations: Setting Limits
Time-Varying and Probabilistic Considerations: Setting Limits

... Figure 10.2 shows a histogram and cumulative distribution function for a typical harmonic voltage measurement, in this case, for a week long measurement. While this data yields information on the time duration at a given distortion level, it does not contain information on the duration of individual ...
SECTION-4-Chapter 10
SECTION-4-Chapter 10

... compatible with the capacitor voltage standard. In many practical installations, however, the majority of the harmonic content is centered at one or two harmonic frequencies. Comparison of THD limits and the capacitor voltage limits shows that capacitor voltage limit is met if the fundamental voltag ...
BDTIC P F C - D C M   I... T D A 4 8 6 2 / T D...
BDTIC P F C - D C M I... T D A 4 8 6 2 / T D...

instruction manual for wire welding machine - Nu
instruction manual for wire welding machine - Nu

... Contact tip: A good contact between the contact tip and the wire ensures a stable arc and optimal current output. Therefore, following steps must be followed: A) The contact tip hole must be kept free of dirt or oxidation. B) After lengthy welds, spatter can easily accumulate on the contact tip and ...
SECTION-4-Chapter_10_Rev1a
SECTION-4-Chapter_10_Rev1a

< 1 ... 117 118 119 120 121 122 123 124 125 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report