
presentation for slide
... worth noting the following of its features which differ from those of the synchronous machine: rotor has a symmetrical structure; hence, d and q axis equivalent circuits are identical rotor speed is not fixed; this has an impact on the selection of dq reference frame there is no excitation sou ...
... worth noting the following of its features which differ from those of the synchronous machine: rotor has a symmetrical structure; hence, d and q axis equivalent circuits are identical rotor speed is not fixed; this has an impact on the selection of dq reference frame there is no excitation sou ...
RF3285 DUAL-BAND GSM850/PCS1900 TRANSMIT MODULE Features
... the effective efficiency by minimizing the PLOSS term in the equation. An ASM may have a typical loss of 1.2dB in LB and 1.4dB in high band. To be added to this is trace losses and mismatch losses. A post PA loss of 1.5dB in LB and 1.8dB in HB is common. With the integration of a low loss pHEMT swit ...
... the effective efficiency by minimizing the PLOSS term in the equation. An ASM may have a typical loss of 1.2dB in LB and 1.4dB in high band. To be added to this is trace losses and mismatch losses. A post PA loss of 1.5dB in LB and 1.8dB in HB is common. With the integration of a low loss pHEMT swit ...
D12E12Safety1\4Curr\emet
... 7.6.23 Explains what meant by single phasing and its effect on a motor: 7.6.23.1 when running 7.6.23.2 when starting 7.6.23.3 if continued attempts to start are made 7.6.24 describe in principle the protection against running with a phase open-circuited 7.6.25 Explain why undervoltage trips are nece ...
... 7.6.23 Explains what meant by single phasing and its effect on a motor: 7.6.23.1 when running 7.6.23.2 when starting 7.6.23.3 if continued attempts to start are made 7.6.24 describe in principle the protection against running with a phase open-circuited 7.6.25 Explain why undervoltage trips are nece ...
Evaluating the Potential of an Energy Reduction Technique Based
... path, since it is expected that a typical circuit delay is shorter than the critical delay and that timing faults rarely occur[7]. For example, it has been reported that nearly 80% of paths have delays of half the critical time[21]. On the other hand, since the checker parts are used for detecting t ...
... path, since it is expected that a typical circuit delay is shorter than the critical delay and that timing faults rarely occur[7]. For example, it has been reported that nearly 80% of paths have delays of half the critical time[21]. On the other hand, since the checker parts are used for detecting t ...
DU36723729
... switching losses and high frequency ringing, which places higher stresses on the components and can cause noise and EMI associated problems. To compensate, inverter designs using MOSFETs have traditionally required the addition of both series and freewheeling ultra-fast diodes. The addition of these ...
... switching losses and high frequency ringing, which places higher stresses on the components and can cause noise and EMI associated problems. To compensate, inverter designs using MOSFETs have traditionally required the addition of both series and freewheeling ultra-fast diodes. The addition of these ...
SG1577A Dual Synchronous DC/DC Controller SG1577A — Dual Sync
... is a single voltage feedback path, including an error amplifier and PWM comparator, as shown in Figure 23. To achieve fast transient response and accurate output regulation, an adequate compensator design is necessary. A stable control loop has a 0dB gain crossing with -20dB/decade slope and a phase ...
... is a single voltage feedback path, including an error amplifier and PWM comparator, as shown in Figure 23. To achieve fast transient response and accurate output regulation, an adequate compensator design is necessary. A stable control loop has a 0dB gain crossing with -20dB/decade slope and a phase ...
CONTROL OF AC LOADS FROM AN AC SUPPLY
... The cycloconvertor is a means of changing the frequency of the alternating supply using controlled rectifiers; this is achieved by ‘steering’ the waveform in the required direction to produce a lower frequency ac voltage on the load. If TH1 and TH3 are fired as the supply alternates from positive to ...
... The cycloconvertor is a means of changing the frequency of the alternating supply using controlled rectifiers; this is achieved by ‘steering’ the waveform in the required direction to produce a lower frequency ac voltage on the load. If TH1 and TH3 are fired as the supply alternates from positive to ...
shutdown on kalpaka-simhadri both circuits
... • INITIALLY AT THE TIME OF SHUT-DOWN, VTS/LANCO TO BE REDUCED BY AROUND 400 MW • MINIMISE GENERATION AT SILERU BASIN • REDUCTION IN GENERATION AT SIMHADRI, COASTAL GAS IF FLOW ON THE LINES ARE NOT BELOW 200 MW EACH • NO LOAD CHANGE OVERS FOR THE PERIOD OF SHUT DOWN IN N.COASTAL AP • FREQUENCY TO BE ...
... • INITIALLY AT THE TIME OF SHUT-DOWN, VTS/LANCO TO BE REDUCED BY AROUND 400 MW • MINIMISE GENERATION AT SILERU BASIN • REDUCTION IN GENERATION AT SIMHADRI, COASTAL GAS IF FLOW ON THE LINES ARE NOT BELOW 200 MW EACH • NO LOAD CHANGE OVERS FOR THE PERIOD OF SHUT DOWN IN N.COASTAL AP • FREQUENCY TO BE ...
FSFR-XS Series — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters
... of RT pin are enclosed by the primary current flow pattern on PCB layout. The direction of the magnetic field on the components caused by the primary current flow is changed when the high- and low-side MOSFET turn on by turns. The magnetic fields with opposite directions induce a current through, in ...
... of RT pin are enclosed by the primary current flow pattern on PCB layout. The direction of the magnetic field on the components caused by the primary current flow is changed when the high- and low-side MOSFET turn on by turns. The magnetic fields with opposite directions induce a current through, in ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.