• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Click Here to Download(PPT)
Click Here to Download(PPT)

... • ASU provided two SEL-351S directional protection systems are interfaced with RTDS to physically detect the fault location and send trip signal to FID’s. • The input of the relays are small ac voltage signals representing secondary currents and voltages at different monitoring locations of the loop ...
DFW Series Wig-Wag Flasher
DFW Series Wig-Wag Flasher

... The DFW flasher unit employs a pair of heavy duty automotive relays, each of which are driven by a silicon transistor connected in a switching configuration. The oscillator circuit provides proven solid state reliability while the relays allow control of heavy load currents without the need for a he ...
STFE Elite Series - Active Tracking® Filters with Surge
STFE Elite Series - Active Tracking® Filters with Surge

... protection to protect against the full spectrum of voltage transients and surges. It continuously tracks the input AC power line responding instantly into action upon detecting extraneous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, motors, ...
Feeder Protection - 123SeminarsOnly.com
Feeder Protection - 123SeminarsOnly.com

IEEE Generator Protection - Levine Lectronics and Lectric
IEEE Generator Protection - Levine Lectronics and Lectric

SPD terminology, references SPD terminology
SPD terminology, references SPD terminology

... safe disconnection under fault conditions. Disconnectors may provide isolation by operating as thermal devices, or overcurrent devices. Following current (IF): generally applies to voltage-switching type SPDs. This is the current delivered by the power distribution system which can be safely extingu ...
Notes on Rebuilding an SB
Notes on Rebuilding an SB

High-Impedance Bus Differential Protection Modeling in ATP/MODELS
High-Impedance Bus Differential Protection Modeling in ATP/MODELS

... The 87Z element is a sensitive, low-impedance, adjustable pick-up current element scaled in voltage [6]. Since the branch current formed by these two components is low, the high-impedance bus differential relay trip becomes dependent on voltage in its terminals. The Metal Oxide Varistor (MOV) is a n ...
Start using solid state relays today
Start using solid state relays today

... Amplicon Serial Comms Why choose Amplicon for serial communications? Amplicon’s broad range of serial communication products serves industrial markets as well as IT applications throughout the world. As a manufacturer we have attained a high level of expertise resulting in outstanding product qualit ...
Electromagnet - SuccessTutor
Electromagnet - SuccessTutor

... through the coil, the soft iron hammer is magnetized with south pole and north pole alternately at the frequency equal to that of the mains. Thus the hammer is set into vibration at the same frequency. • Use T = 1/f, hence the time is obtained. ...
E044081720
E044081720

Download PGR-8800 Datasheet
Download PGR-8800 Datasheet

OTB1C0DM9LP - Schneider Electric
OTB1C0DM9LP - Schneider Electric

... I/O distributed module OTB - CANopen bus 0..1000 m ...
Electrician`s Guide to Elegance
Electrician`s Guide to Elegance

... Elegance 24 and 48 relay panels are supplied with either isolated neutral bus bars, or bakelite terminal blocks which will isolate each neutral circuit from all the others. If you have received the wrong style neutral hardware for your installation, you may request the opposite style by calling Cent ...
Analysis and Demonstration of MEM
Analysis and Demonstration of MEM

... function of the peak-to-average ratio k of the on-state current. This stems from the fact that both relay and MOSFET power gates must be sized to achieve a certain IR drop under worst-case load conditions. In the case of MOSFET power gates, the increased transistor width (vs. a power gate sized for ...
OLTC - IEEMA
OLTC - IEEMA

... With this practice OLTC conservator is kept near to OLTC at reduced height than the main conservator. A pressure difference depending upon the height difference appears on OLTC diverter and all sealing joints of OLTC for its life time when conservators are placed at different heights, which OLTC is ...
Solid-State Relays 31
Solid-State Relays 31

... once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. ...
0112612009 I General  Information  or  Other  (PAR) Event#
0112612009 I General Information or Other (PAR) Event#

- aes journals
- aes journals

... The trip logic of various numerical distance relays has been implemented using various functional blocks available in the software. The trip signals of these numerical distance relays have been observed by incorporating them in a power system modeled using the software. The working of the simulated ...
IOSR Journal of Electrical and Electronics Engineering PP 46-54 www.iosrjournals.org
IOSR Journal of Electrical and Electronics Engineering PP 46-54 www.iosrjournals.org

EE 1090510
EE 1090510

... seen by distance relays due to the fast response time of FACTS Controllers with respect to that of the protective devices. Therefore, it important to study how distance relays would perform when protecting transmission lines equipped with FACTS Controllers. TCSC is one the FACTS Controller device th ...
Terms and Abbreviations
Terms and Abbreviations

... Apparent Power - The power value obtained by multiplying the current by the voltage (P = I X E). 9. Axial dimension - This term is used for the measurement of the coupler distance during the generator coupler alignment procedure. 10. CB - Circuit breaker - provides power to individual circuits – als ...
Flashing light 10 Joules Quadro F12-SIL
Flashing light 10 Joules Quadro F12-SIL

... Additional mounting possible via external lugs (included). ...
DND5057 - pes-psrc
DND5057 - pes-psrc

... (usually “on” - “off” power line carrier) is used to block tripping at the remote terminal for external faults. Tripping is accomplished by forward overreaching elements in the absence of a blocking signal from the remote terminal. See: directional comparison protection. Directional comparison unblo ...
Ultra-miniature, Highly Sensitive SPDT Relay for Signal
Ultra-miniature, Highly Sensitive SPDT Relay for Signal

< 1 ... 44 45 46 47 48 49 50 51 52 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report