Islanding wikipedia , lookup

Electrical ballast wikipedia , lookup

Ohm's law wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Current source wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

History of electric power transmission wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Rectifier wikipedia , lookup

Power MOSFET wikipedia , lookup

Electrical substation wikipedia , lookup

Metadyne wikipedia , lookup

Voltage regulator wikipedia , lookup

Power electronics wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Distribution management system wikipedia , lookup

Opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Ground (electricity) wikipedia , lookup

Earthing system wikipedia , lookup

Mains electricity wikipedia , lookup

Surge protector wikipedia , lookup

Transcript
MA15 Series Power/Surge Diverter
Power Surge Protection for ELPRO Products
Specifications
Parameters
Description
Lines Protected
L-N, L-E, N-E
Working Voltage
120VAC/140VDC: MA15/D/1 240VAC/280VDC: MA15/D/2
Max Continuous Voltage
25% Above Nominal
Nominal Current
120V @ 15A/240V @ 10A, Unlimited Parallel Connection
Max Surge Current
18kA (8/20us)
Limit voltage @ 500A ring
295V (120Vac), 356V (240Vac)
Limit voltage @ 500A 8/20us
320V (120Vac), 800V (240Vac)
Limit voltage @ 3kA 8/20us
585V (120Vac), 1210V (240Vac)
Max Leakage Current
<0.3mA
Attenuation
55dB @ 100MHz
Compliance
The MA15 Surge Diverter combines surge protection with transient filtering
and ring-dampening, and is designed to protect the AC/DC input of electronic
equipment from surge voltages. Thermal fusing and short circuit protection
are also incorporated. In addition power-on and protection preset is indicated
by LED indication.
EMC
EN 60950, EN 61000-6-2
Safety
UL 1449
Size
25mm x 79mm x 91mm (0.98” x 3.11” x 3.58”)
Housing
Polymide-PA, with G- or T-section (Top-hat)
DIN Rail Mounting Foot UL94-V0
Mounting
T-section DIN Rail 35 x 15mm (1.37” x 0.59”)
Note: Surge Protection Devices rely on good earth grounding practices to be
effective. This product assumes both a metallic enclosure and good ground
connection to the enclosure. If in doubt, apply another earth ground under the
locknut to create a sufficient earth ground.
Terminal Blocks
2.5mm2 (12AWG)
Temperature Rating
-40 to 85°C (-40 to 185°F)
Humidity Rating
5 to 95% Non-condensing
Weight
100g (3.53oz)
Warning: Do not stand near or touch operating equipment during an electrical
storm as the MA15 will not protect personnel.
LED Indication
Green LED: On Protection Present; Green LED Off: Internal Fail
For currents greater than 15A, multiple MA15 units can be commissioned in
parallel for increased surge protection.
General
Note: Specifications subject to change.
Ordering
To order, select product code from the table and specify country of application.
Product Code
Description
MA15/D/1/SI
120Vac/140Vdc
MA15/D/2/SI
240Vac/280Vdc
Product Compatibility
Please refer to product datasheets for compatibility details to suit your application.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product
data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper
Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
©2013 Cooper Bussmann
www.cooperbussmann.com/wireless
0913
BU-SB13107
Page 1 of 1