* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Motion Along a Straight Line at Constant
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power factor wikipedia , lookup
Power inverter wikipedia , lookup
Audio power wikipedia , lookup
Transformer wikipedia , lookup
Opto-isolator wikipedia , lookup
Wireless power transfer wikipedia , lookup
Power over Ethernet wikipedia , lookup
Electric power system wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Electric power transmission wikipedia , lookup
Transformer types wikipedia , lookup
Three-phase electric power wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Electrical substation wikipedia , lookup
Distribution management system wikipedia , lookup
Electrical grid wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Distributed generation wikipedia , lookup
Electrification wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power engineering wikipedia , lookup
Mains electricity wikipedia , lookup
Book Reference : Pages 131-132 1. To understand how electricity is distributed in the UK via the National Grid 2. To understand how transformers are used to minimise energy losses due to heat during electricity distribution The UK network of cables (underground and on pylons), transformers and power stations is known as the National Grid. Power stations produce electricity at 25 kV and at 50Hz Each power station may well produce in the order of 50-100 MW of electrical power When high currents flow through wires, there is a heating effect (I2R). To achieve a given power distribution, there is a choice of voltage and current (P=VI). To reduce the energy lost due to heating, the electricity is distributed at a higher voltage and lower current In particular step up transformers are used between the power station and the grid to achieve a transmission voltage of 275-400kV Power Station : 25kV National grid : 250-400kV Industry 11-33kV (Three phase) Homes 230V (Single Phase) Power = Current x Voltage (P=VI) Voltage = Current x Resistance (V=IR) Power lost in the cable due to heating = P = I2R If a transmission line has a resistance of 500 and carries 1MW of power at 25kV. Then the current will be 40A and the power loss 0.8MW However at 400kV the current reduces to 2.5A and the energy loss reduces to 3.1kW A transformer has a primary coil with 120 turns & a secondary with 2400 turns. Calculate the required primary voltage to achieve a secondary voltage of 230V [11.5V] A 230V 60W lamp is connected to the secondary coil. Calculate the current through 1. The secondary coil [0.26A] 2. The Primary coil [5.2A] Explain why the transmission of electrical power over long distances is more efficient at higher rather than lower voltages A power cable has a resistance of 200 is used to deliver 2.0MW of power at 120kV. Calculate : 1. The current through the cable [16.7A] 2. The power wasted in the cable [56kW]