Download T4800 SERIES

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spectral density wikipedia , lookup

Spark-gap transmitter wikipedia , lookup

Audio power wikipedia , lookup

Chirp spectrum wikipedia , lookup

Power factor wikipedia , lookup

Opto-isolator wikipedia , lookup

Electrical ballast wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Current source wikipedia , lookup

Electric power system wikipedia , lookup

Power inverter wikipedia , lookup

Rectifier wikipedia , lookup

Electrical substation wikipedia , lookup

Stray voltage wikipedia , lookup

Heterodyne wikipedia , lookup

Electrification wikipedia , lookup

Surge protector wikipedia , lookup

Voltage regulator wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power engineering wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Islanding wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power electronics wikipedia , lookup

Voltage optimisation wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Buck converter wikipedia , lookup

Three-phase electric power wikipedia , lookup

Alternating current wikipedia , lookup

Utility frequency wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Generator Control
Basic
T4800 SERIES
Load Sharer for Conventional Governors
Description
The T4800 Load Sharer provides automatic load sharing and
frequency control for parallel running generators. The load
sharing is proportional, meaning that the generators will be
loaded equally compared to their individual capacity.
The load on each generator is compared with the load on
the other generators and corrected until balance is obtained.
Load sharing is necessary after synchronization in order to
reestablish load balance and to obtain long term stability of
load and system frequency (compensating the droop of the
speed governor).
The T4800 has a built-in reverse power protection with
selectable limits and time delays.
Features & Benefits
Simplified Circuit Diagram
17
18
19
20
REVERSE POWER
1
UN
2
3
21
22
23
T4800
(Load Sharer)
4
5
IN
6
24
25
26
FEATURES
27
TRIP
FREQ. FREQ.
UNLOAD OUT IN
7
8
9
28
29
SYNC. FREQ.
IN
30
WATT TEST PARALLEL
LINES
IN
OUT
COM. +
–
–
10
11
12
31
32
AUTO
INCR. DECR.
13
14
15
16
13
UNLOAD
NEXT
T4800
12
M
L1
L2
GEN
L3
BUS
Adjustable delta frequency,
stability and % load
deviation by front panel
potentiometers
Inputs for disabling internal
frequency control
Enables operation where system frequency
is set externally such as in grid-parallel
operation
Reverse power trip
Economic solution for reverse power
protection
Visual indication of voltage,
increase/decrease and
unload signals
Direct line-line voltage
supply (up to 690 Vac)
Galvanic isolated inputs
C/B
SYNC. T4500
DIN rail or screw-mount
Ordering Information
Provides quick and concise status
information
Simplifies design and installation–no need for
PTs–or separate power supply
Protects the unit against high AC voltage and
currents from the installation including spikes
Easy installation
Specifications
ORDERING
NUMBER
TERMINALS
1-1
1-3
T4800.0010
450 V
400 V
T4800.0020
230 V
T4800.0030
480 V
415 V
5A
T4800.0040
110 V
100 V
1A
T4800.0050
450 V
400 V
1A
T4800.0060
127 V
120 V
5A
T4800.0070
110 V
100 V
5A
IN
5A
5A
Other supply voltages, nominal currents and combinations are available on request.
© 2014 Littelfuse Protection Relays & Controls
www.littelfuse.com/t4800
BENEFITS
Facilitates adjustment during installation and
commissioning. Load deviation adjustment
enables paralleling of differenst size
generators.
Max. Voltage
Voltage Range Consumption Continuous Current Frequency Range Frequency Adjustment Proportional Band
Dead Band Zone
Contact rating Operating Temperature Vibration Test EMC Approvals Burn-in Enclosure Material Weight Dimensions Installation 660 V
70-110%
Voltage 4 VA at UN; Current 0.4 VA at UN;
2 x IN
35-70 Hz
48-62 Hz
±50 - 250% load; ±5 - 25% frequency
±2 - 10% load; ±0.2 - 1.0% frequency
AC: 400 V, 2 A, 250 VA
DC: 110 V, 2 A, 100 W
–20°C to +70°C
4 g RMS according to IEC 60068-2-64
CE according to EN50081-1, EN50082-1,
EN50081-2, EN50082-2, EN61000-6-2:1999
Certified by major marine classification societies
50 hours before final test
Polycarbonate, flame retardant
0.7 kg
H 70 mm (2.7“); W 150 mm (5.9“);
D 115 mm (4.5“)
35 mm DIN rail or 4 mm (3/16”) screws
Rev: 4-B-111014