Download SMARTHOME™ 1-800-SMART-HOME 949-221

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Fault tolerance wikipedia , lookup

History of electromagnetic theory wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Portable appliance testing wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Stepper motor wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Electrical substation wikipedia , lookup

Stray voltage wikipedia , lookup

History of electric power transmission wikipedia , lookup

Flexible electronics wikipedia , lookup

Printed circuit board wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Mains electricity wikipedia , lookup

Single-wire earth return wikipedia , lookup

Three-phase electric power wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Overhead line wikipedia , lookup

Aluminium-conductor steel-reinforced cable wikipedia , lookup

Gender of connectors and fasteners wikipedia , lookup

Ground (electricity) wikipedia , lookup

Alternating current wikipedia , lookup

Skin effect wikipedia , lookup

Wire wrap wikipedia , lookup

Residual-current device wikipedia , lookup

Earthing system wikipedia , lookup

Electrical wiring wikipedia , lookup

Surge protector wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

National Electrical Code wikipedia , lookup

Transcript
----~-- --
~__
TD BE INSTALLED AND OR USED IN ACCORDANCE
WITH APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNINQ:
TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF
POWER AT CIRCUIT BREAKERS OR FUSES. TEST
THAT POWER IS OFF TO BOTH RECEPTACLES
BEFORE WIRING! Use this device only with copper
or copper-clad wire. With aluminum devices, use only
devices marked CO/ALR.
STEP Al. Remove the wallplate and OLD receptacle.
STEP AZ. Disconnect the circuit conductors from the
OLD receptacle.
STEP A3. Install the Surge Suppressor receptacle as
follows according to wiring diagram A: Connect the
white NEUTRAL conductor securely under the SILVER
colored terminal screw (labelled WHITE on the back of
the unit). Connect the black or red HOT conductor
securely under the BRASS colored terminal screw
(labelled BLACK on the back of the unit).
l THIS DEVICE IS INTENDED FOR SINGLE BRANCH
CIRCUITS ONLY.
*THIS DEVICE IS NOT A LIGHTNING ARRESTOR. IT
WILL NOT SURVIVE LIGHTNING STRIKES IN CLOSE
PROXIMITY TO THE PREMISES.
Use a test lamp to confirm that BOTH outlets on the
existing receptacleare NOT wered. If the test lamp
does not Ii ht, proceed to p
tep A below. If the test
lamp DOE!3 light for one outlet and not the other,
proceed to INSTRUCTIONS FOR REPLACING A
SPLIT-FEED WIRED RECEPTACLE WITH A SURGE
SUPRESSOR RECEPTACLE.
STEP A4. Connect tfte bare or green wire grounding
conductor in the wallbox to the GREEN or BARE
grounding lead as follows:
Twist bare wire ends together tightly and twist a wire
connector over the connection. Secure the connector with electrical tape.
STEP AS. Mount the Surge Suppressor receptacle into
its wallbox with the U-ground slot upwards, using the
two
long metal screws provided.
STEP A6 Attach the wallplate provided.
STEP A7. Restore power at the fuse or circuit breaker.
Installation is complete.
7
WIRING DIAGRAM A (END OF LINE)
5
6
i -.
--
INSTALLING A SURGE SUPPRESSOR
RECEPTACLE AT THE END OF LINE
TO INSTALL
INSTALLING THE SURGE SUPPRESSOR
RECEPTACLE IN PLACE OF A RECEPTACLE IN A
FEED-THROUGH BRANCH CIRCUIT
STEP 83. Begin by removing the wallplateand the OLD
receptacle and examining the wire terminals,
STEP B4. Disconnect the two wires connected under
the silver-colored terminal screws on the OLD receptacle (should be white NEUTRAL conductors), Pigtail
them together with a short length of white insulated
copper wire of the appropriate gage, using a wire connector, until no bare copper shows (see Diagram B).
Secure the connector with electrical tape. Secure the
other end of the white pigtail lead tightly under silvercolored terminal screw (labelled“WHITE”on the back of
the device) on the Surge Suppressor receptacle.
STEP 65. Disconnect the two wires connected to
the brass-colored terminal screws on the O L D
receptacle (should be the black or red HOT conductors). Pigtail them securely together with a short
length of black insulated copper wire of the appropriate gauge, using a wire connector until no bare wire
shows (see Diagram B). Secure the connector with
electrical tape. Secure the other end of the black
pigtail lead tight1 under the brass-colored terminal
screw (labeled 114;LACK” on the back of the device)
on the Surge Suppressor Receptacle.
STEP 66. Disconnect the bare orgreen grounding conductor from the green screw on the OLD receptacle.
10
NDiE: A Surge Suppressor receptacle in a feedthrough branch circuit will provide protection only for
loads plugged directly into it. It WILL NOT provide protection to any other receptacles on the same branch
circuit.
Furthermore,although replacing a feed-through receptacle with a Surge Suppressor receptacle is permitted, it
is m recommended because the wallbox may not
have sufficient volume to contain the device, wire leads
and wire connectors required for’proper installation.
STEP Bl. Select the receptacle which will be replaced
by the Surge Suppressor receptacle. Turn off power to
this receptacle by removing the fuse or turning the circuit
breaker OFF
STEP 82. Use a test lamp to confirm that BOTH outlets
arq,NDT powered. If the test lamp does light for one
outlet and not the other, proceed to INSTRUCTIONS
FOR REPLACING A SPLIT-FEED RECEPTACLE
WITH A SURGE SUPPRESSOR RECEPTACLE. If the
test lamp does not light for either outlet, proceed to step
83 below.
8
-
..
P
WIRIRG DIAGRAM B
9
STEP Cl. Use a test lamp to confirm that BOTH outlets
-- are NOT powered. If the test lamp indicates that one _
- Connect this lead securely to the green grounding tead
as follows (see Diagram 6):
twist the bare wire ends tightly together and twist a wire
connector over the connection Secure the connector
with electrical tape.
STEP 87. Mount the Surge Suppressor receptacle into
its wallbox with the U-ground slot upwards, using the two
long metal screws provided.
STEP B8. Attach the wallplate provided.
STEP B9. Restore power at the fuse or circuit breaker.
Installation is complete.
outlet is still “live” and one is off after the power has been
disconnected, then the OLD receptacle is split-wired
(each outlet is powered by a different branch circuit).
Turn the power OFF to the remaining “live” outlet by
removing the fuse or turning the circuit breaker OFF
Confirm that the power to both outlets is OFF using the
test lamp.
STEP C2. With the power to both outlets of the OLD
receptacle shut OFF; remove the wallplate and withdraw
the OLD receptacle from its wallbox. Do NOT disconnect any circuit conductors yet.
STEP C3. Identify all the conductors on the OLD splitwired receptacle (see Wiring Diagram C). There should
be a bare or green grounding conductor present in the
wallbox, which is necessary for the installation of the
Surge Suppressor receptacle. There will also be four
other conductors making up two “pairs:’Each pair Consists of one black or red HOT conductor and one white
NEUTRAL conductor. Since the Surge Suppressor
receptacle CANNOT BE SPLIT WIRED, one Pair WitI
have to be selected as a source before proceeding with
the installation.
INSTRUCTIONS FOR REPLACING A SPLIT-FEED
WIRED RECEPTACLE WITH A SURGE
SUPPRESSOR RECEPTACLE
NOTE: Although replacing a split-feed receptacle with a
Surge Suppressor receptacle is permitted, it is NOT
recommended because the wallbox may not have sufficient volume to contain the device, wire leads and wire
connectors required for proper installation. Also, one
circuit pair will need to be capped and left unused in the
wall box.
11
--a__-
STEP C4. Disconnect the wires connected to the’
silver-colored terminal screws on the O L D
13
WIRING DIAGRAM C
--------ruF-- --
12
-
-----‘
---~----~
---
SMARTHOME™ 1-800-SMART-HOME 949-221-9200 http://www.smarthome.com Order #865131
-
--
i
receptacle (should be white NEUTRAL conductors).
Choose the neutral conductor you will NOT be using and twist a wire connector over the end of that
conductor until no bare copper wire shows (see
Diagram D). Secure the connector with electrical
tape:
‘If the split-feed wired receptacle is powered from a
cable having two HOT conductors, a common NEUTRAL (white) conductor and a green or bare grounding
conductor, connect the NEURTRAI as described in C6.
STEP CS. Disconnect the wires connected to the
brass-colored terminal screws on the OLD receptacle
(should be black or red HOT conductors). Choose the
hot conductor you will NOT be using from the same line
pair that the unused neutral was chosen from. Twist a
wire connector over the end of that conductor (see
Diagram C). Secure the connector with electrical tape.
‘If the split-feed wired receptacle is powered from a
cable having two HOT conductors, a common NEUTRAL (white) conductor and a green or bare grounding
conductor, choose the HOT conductor you will NOT be
using. Twist a wire connector over the end of that conductor. Secure the connector with electrical tape. Connect the remaining HGT conductor as described in C7.
STEP C6. Install the Surge Suppressor receptacle, according to Diagram C. as follows: Connect the remaining white NEUTRAL conductor securely under the
SILVER colored terminal screw (labelled WHITE on the
back of the unit).
STEP C7. Connect the remaining black or red HOT
conductor securely under the BRASS colored terminal
screw (labelled BLACK on the back of the device).
STEP C8. Connect the bare or green grounding conductor in the wall box to the GREEN grounding lead on
the Surge Suppressor receptacle as follows:
Twist the bare wire ends tightly together and twist a wire
connector over the connection. Secure the connection
with electrical tape.
STEP C9. Mount the Surge Suppressor receptacle into
its wallbox with the U-ground slot upwards, using the two
long metal screws provided.
STEP ClO. Attach the wallplate’provided.
STEP Cll. Restore power at the fuse or circuit breaker.
Installation is complete.
SMARTHOME™ 1-800-SMART-HOME 949-221-9200
http://www.smarthome.com Order #865131
15
OPERATION
SPECIFICATIONS
UL 1449
Transient Suppression
Volta e Rating:
Line-aeutral
Line-Ground
Neutral-Ground
Energy Rating
(1 O/l Ooo microseconds):
140 Joules
Line-Neutral
70 Joules
Line-Ground
70 Joules
Neutral-Ground
Peak Surge Current
8/20 microseconds):
Line-Neutral
Line-Ground
Neutral-Ground
13000A
tzK
INSTALLATION INSTRUCTtONS
IMPORTANT SAFETY INSTRUCTIONS AND
Transient voltage surges, or “spikes,” may originate by
CAUTION NOTICESthe switching on and off of electric motors or other heavy
PLEASE READ BEFORE INSTALLING
electrical loads on the circuit, static discharges, or from
Carefully read the installation instructions before
external influences on the power grid. TheLeviton Commercial Grade Surge Suppressor Receptacles are in- beginning your intended installation. IF YOU DO NOT
tended for use with sensitive electronic equipment, such UNDERSTAND ANY PART OF THEM, CONSULT A
as computers, electron/c analysis and monitoring equip- QUALIFIED ELECTRICIAN.
ment and other appliances with solid state circuitry that n Install this device only in a single branch circuit prowould benefit from protection against the damage
tected by a fuse or circuit breaker. This device helps
caused by transient surges.
protect against transient voltage surgesat this receptacle on/y. It DOES NOT supply ground fault or overload protection.
INDICATOR LIGHT OPERATION
The Indicator Light ‘denotes surge SUpPreSSiOn is
effective when it is continuously ON.
l When the indicator light turns OFF, the device is
no longer providing suppression due to damage
caused by excessive transient surges. The entire unit
must be replaced, if surge suppression is required. If
the unit is not replaced, it will function only as a
conventional receptacle within its given rating.