* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Power supply 230 V
Ground (electricity) wikipedia , lookup
Standby power wikipedia , lookup
Opto-isolator wikipedia , lookup
Wireless power transfer wikipedia , lookup
Stray voltage wikipedia , lookup
Power factor wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical substation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Surge protector wikipedia , lookup
Audio power wikipedia , lookup
Power MOSFET wikipedia , lookup
Earthing system wikipedia , lookup
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power over Ethernet wikipedia , lookup
Electrification wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power electronics wikipedia , lookup
Distribution management system wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Power supply wikipedia , lookup
TECHNICAL SHEET Power supply 230 V 035 67 Description 1 The power supply unit can be used to power Automation and Thermoregulation systems. Its output supplies a continuous 27 Vdc low voltage supply with 600 mA maximum current, and is protected from short circuit and overload by a built-in fuse (non replaceable). It's a double insulation safety device in accordance with CEI EN60065 standards, and therefore comparable to a SELV source as described in paragraph 411.1.2.5 of CEI 64-8-4 standard. The power supply is inside a 2 module DIN rail container, and its installation must be in accordance with the current regulations of the country of use. As a general rule, the following must be complied with: - The power supply must always be installed inside appropriate containers - It must not be subjected to water drips or sprays - The air circulation holes must not be obstructed - A double-pole switch must be used, with 3mm min. contact separation, installed in the proximity of the power supply. The switch is needed to disconnect the power supply unit from the power supply network, and to protect it. PRI 035 67 PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz SCS: 27 Vdc 600 mA The device does NOT need configuring. 2 SCS Technical data PRI (AC power supply input) - Rated voltage: - Rated current: - Operating voltage range: - Operating frequency range: - Input power at full load: - Dissipated power: - Full load performance: - Stand by power: - Operating temperature: - Built-in fuse (PRI side): 3 Legend 1. Clamp (PRI) for the connection of the power supply voltage 2. LED:– green (power supply on) – red (output current overload) 3. Clamps (SCS) for SCS BUS connection 1 LG00133-b-UK 27 V +/- 100 mV 0 – 0.6 A 16,2 W B U S S C S s y ste m SCS - Rated voltage: - Rated current: - Rated power: 220 – 240 V 185 – 175 mA 187 – 265 V 47 – 63 Hz 21,5 W max 5,3 W max 80% typ. minore di 1 W 5 – 40 °C F1 T2A 250V (NON REPLACEABLE)