* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Power supply 230 V - HomeSystems Legrand
Standby power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power factor wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Stray voltage wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Electric power system wikipedia , lookup
Audio power wikipedia , lookup
Electrification wikipedia , lookup
Distribution management system wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power MOSFET wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power over Ethernet wikipedia , lookup
Buck converter wikipedia , lookup
Earthing system wikipedia , lookup
Power engineering wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power supply wikipedia , lookup
Switched-mode power supply wikipedia , lookup
teCHNICAL SHeet Power supply 230 V 035 60 Description The power supply must be used to supply power to the Automation and Temperature control systems. On the output, the unit supplies a 27 Vdc continuous low voltage, with a maximum current of 1.2 A. It is electronically protected (without fuses) against short circuit and overload. It’s a double insulation safety device in accordance with CEI EN60065, and can therefore be combined with a SELV source as described in section 411.1.2.5 of CEI 64-8-4. The power supply is made inside a 8 DIN module rail enclosure, and its installation must be in accordance with the regulations of the country of use. In general, the following requirements must be met: - The power supply must be installed in appropriate enclosures. - The device must be kept away from water drips and sprays. - Care must be taken not to obstruct the air vents. - A two-pole circuit breaker must be installed, with contact separation of at least 3 mm located nearby the power supply unit. The circuit breaker is used to disconnect the power supply from the mains, and to protect it. Technical data Power supply voltage: Max. input absorption: Output voltage: Maximum power delivered: Max. power consumption: Standards: Protection degree: Operating temperature: 035 60 230 ±10% V 50-60Hz IMAX =300 mA sortie 27V 1,2A T=5÷40°C N646 IP30 3 2 1 Legend 1. Terminals (1-2) DC output 2. Terminals (bus) to connect the SCS BUS 3. Terminals to connect the power supply voltage 230 Vac +/- 10% @ 50/60 Hz 300 mA 27 Vdc 1.2 A 11 W CEI 64-8 (ref CEI 64-8-4 par 411.1.4) IP30 5 – 40 °C Dimensional data 1 LG00035-b-UK SCS BUS SyStem Size: 8 DIN modules