Download system interface application (apfiff10)

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power inverter wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Relay wikipedia , lookup

Electrical substation wikipedia , lookup

Switch wikipedia , lookup

Alternating current wikipedia , lookup

Rectifier wikipedia , lookup

Ground (electricity) wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Stepper motor wikipedia , lookup

Resilient control systems wikipedia , lookup

Potentiometer wikipedia , lookup

Integrating ADC wikipedia , lookup

Stray voltage wikipedia , lookup

Control theory wikipedia , lookup

Mains electricity wikipedia , lookup

Distributed control system wikipedia , lookup

Distribution management system wikipedia , lookup

Automation wikipedia , lookup

Voltage optimisation wikipedia , lookup

Voltage regulator wikipedia , lookup

Buck converter wikipedia , lookup

Schmitt trigger wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Control system wikipedia , lookup

Opto-isolator wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
system interface application (apfiff10)
Overview
The System Interface Application is designed to provide
machine controllers with a logical and flexible interface to
be used in demanding applications. It can also be used for
any general purpose drive system. The same application can
be used for almost all the drives in the system which makes
it easy for the customer to maintain.
The System Interface Application is typically used in
coordinated drives with overriding control system. The
recommended interface to control the system is fieldbus
communication. Hardwired analogue and digital signals, as
well as keypad and PC control, can also be used.
System Interface Application utilizes the most advanced
functions in NXP motor control software and is suitable for
demanding drive systems like paper machines and drives in
metal industry and processing lines. It can also be used for
any other standard applications. This application software is
well-suited for the following uses:
•
•
•
Pulp and paper machine drives, e.g. dryers, press
section, wire section, pope reels, winders and
unwinders.
Drives in metal industry, e.g. casting machines, melt
shops or preparing lines
Standard drives, such as pumps and fans, lifts, cranes,
conveyors, etc.
Features and benefits:
•
•
•
•
•
•
•
•
•
•
•
•
•
Advanced fieldbus communication with
flexible process data connections
Flexible speed and torque reference chain
Master Follower Speed /Torque
Mechanical brake control and motor fan control
Control of drive from Fieldbus, I/O control, Keypad/PC
Two constant speeds with separate ramps
Emergency stop with separate ramp
Supports PT100 temperature measurements
using Analog Input and Analog Output
Supports permanent magnet motors
and multiple winding motors.
Automatic identification run
Inertia compensation and oscillation damping features
Programmable U/f curve and flux curve
Programmable I/O
Vacon Plc
Runsorintie 7, 65380 Vaasa, Finland
[email protected]
Tel. +358 (0)201 2121
Fax +358 (0)201 212 205
Control I/O
Terminal
Signal
Description
1
+10V
Reference output
Voltage for potentiometer, etc.
2
AI1+
Analogue input,
voltage range 0—10V DC
Voltage input frequency reference
3
AI1-
I/O Ground
Ground for reference and controls
4
AI2+
AI2-
Analogue input,
current range 0—20mA
Current input frequency reference
5
6
+24V
Control voltage output
Voltage for switches, etc. max 0.1 A
7
GND
I/O ground
Ground for reference and controls
8
DIN1
Start forward (Programmable)
Contact closed = start forward
9
DIN2
Start reverse (Programmable)
Contact closed = start reverse
External fault input
(programmable)
Contact open = no fault
Contact closed = fault
10 DIN3
11 CMA
Common for DIN 1—DIN 3
Connect to GND or +24V
12 +24V
Control voltage output
Voltage for switches (see #6)
13 GND
I/O ground
Ground for reference and controls
14 DIN4
Run Enable
Contact closed = Run Enable
Contact Open =Run Disable
15 DIN5
Main Switch Ack.
Contact closed = Switch is closed.
Contact Open= Switch is open.
16 DIN6
mA
READY
Emergency Stop
Contact open= EmstopActive.
Contact Close = Emstop not active.
17 CMB
Common for DIN4—DIN6
Connect to GND or +24V
18 AOA1+
Programmable
Programmable
Range 0—20 mA/RL, max. 500WΩ
Digital output
READY
Programmable
Open collector, I≤50mA, U≤48 VDC
19 AOA120 DOA1
21 RO1
RUN
22 RO1
Relay output 1
RUN
Programmable
Relay output 2
DC bus Charging OK
Programmable
23 RO1
24 RO2
220
25 RO2
VAC
26 RO2
Application Note
AN00014B