* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Mains Frequency to Current/ Voltage Converter E1 - Lee
Ground (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electric power system wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Audio power wikipedia , lookup
Power engineering wikipedia , lookup
Utility frequency wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical ballast wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Current source wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Integrating ADC wikipedia , lookup
Distribution management system wikipedia , lookup
Power MOSFET wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Schmitt trigger wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Surge protector wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage regulator wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
AlphaPOWER Range Mains Frequency to Current/ Voltage Converter E1-FREQ Function: Electrical mains frequency to dc current or voltage converter. The measured input is isolated, filtered, squared-up and offered to a precision frequency to current converter. The current is amplified and compared to an accurate reference. A symmetrical dc amplifier converts the resultant to the required voltage or current ouput suited to driving meters, computer inputs and process control systems. Using the latest technology in converter integrated circuits, dc amplifiers and reference circuits, the E1-FREQ offers exceptional accuracy and stability with increased immunity to spikes and distorted waveforms. The E1-FREQ is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. SPECIFICATIONS INPUT: OUTPUT: SUPPLY: GENERAL: Frequency 45 to 55 Hz or 45 to 65 Hz DC Current 0 to 1mA into 10K ohms 0 to 10mA into 1K ohms 0 to 20mA into 500 ohms 4 to 20mA into 500 ohms Power Supply Voltage 110 Volt AC ±20% 230 Volt AC ±20% 400 Volt AC ±20% Power Supply Burden 1.8VA Accuracy Class 0.01% of span Option: Other frequency ranges available as an optional extra, i.e. 400Hz DC Voltage 0 to 10 Volts into 2K ohms minimum Voltage Level 110 Volt AC 220 Volt AC 230 Volt AC 240 Volt AC 380 Volt AC 400 Volt AC or 415 Volt AC Option: Zero and Span Calibration potentiometers available through the front panel as an optional extra Options: Non Standard AC power supplies or 24 Volt DC power supply Response Time 0 to 80% 300mS maximum Storage Temperature Range –40 to +70°C Operating/Storage Humidity Range 0 to 90% RH non-condensing Option: 4000 Volts DC Ripple <1% peak to peak Mounting Standard 35mm DIN rail EMC Error (one off peak) Maximum of –15% Vertical error @ 450 MHz and 10 Volts per metre Voltage Burden 1.2VA Temperature Coefficient 0.3% / 10°C Operating Temperature Range –10 to +60°C Isolation 2000 Volts DC or peak AC for 1 minute Option: Other voltage levels available as an optional extra Stability +0.05% per annum N.A. Protection Level Self extinguishing box to VDE0304 Degree 1 Weight 390 gms approx. TERMINATION DETAILS MECHANICAL DETAILS CONNECTION DETAILS The voltage inputs may be direct or VT connected in which case one side of the VT secondary should be earthed. We recommend that the voltage inputs and power supply are fused. OUTPUT + – 15 16 70 E1-FREQ 2 5 13 14 ~~ 55 (+) (–) POWER SUPPLY 114 L x N ORDERING DETAILS (a) Give identification code, i.e. E1-FREQ (b) Give details of input frequency range, i.e. 45 to 65Hz (c) Give details of input voltage level, i.e. 240 Volt AC (d) Give details of output required, i.e. 4 to 20mA (e) Specify options required (if required), i.e. 4KV Isolation LEE -DICKENS LTD Desborough, Kettering, Northants NN14 2QW U.K. Te l : ( 0 1 5 3 6 ) 7 6 0 1 5 6 F a x ( 0 1 5 3 6 ) 7 6 2 5 5 2 4.8