Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Rectiverter wikipedia , lookup
About us HBL Power Systems Limited is an acknowledged leader in the eld of specialized batteries and DC Power Systems in India. We manufacture batteries that run large submarines, Power Artillery Fuzes, Railway coaches, Telecom towers and Military equipment. Products offered ABM-Advanced Battery Monitoring System HBL manufacture related electronic equipment like Battery Chargers, SMR, UPS, Inverters & Controllers, IPS etc. Batteries in all these equipment perform more efciently and longer when closely monitored and supervised. Designed to monitor individual cells / battery blocs & control the charge/discharge operations on battery systems ranging from 24V. Modular architecture of this system allows management of multiple battery systems simultaneously from a centralized monitoring system. HBL offers advanced battery monitoring systems where power and system availability are critical to successful business operations, with features that suit your requirement and budget. System communicates using RS485 & Ethernet/TCP protocols. Best suited for compact batteries where individual processors cannot be mounted on the cell and where running sensing cables is not a constraint. Low cost system Benefits of Battery Monitoring Systems Automated capturing of data reduces the human errors. Noties users in case of alarms using the advantages of latest technologies. Provides the state of readiness of battery at any time. Allows for early detection of weak cells before they risk the integrity of the battery. Analyzing the data provided by the system allows remedial actions for cells to extend their life. Enables procurement of batteries through planned schedules, not emergency replacement. Improves the battery reliability while providing an ongoing return on investment. BMS outputs when needed can be used in DC power plants, Rectiers, Inverter Systems to trigger an equalization charge remotely. Suitable to monitor any type of battery i.e. Nickel Cadmium (NiCd), Nickel-Metal Hydride (NiMH), Lead Acid, Lithium Ion (Li-ion) etc. Our Features Measures battery parameters such as individual cell voltage, string voltage, battery current, cell terminal temperature, cell/battery compartment temperature, room temperature. Provide warnings of impending malfunction based on set limits such as TBM-Telecom Battery Monitoring System Telecom battery monitoring system (TBM) has been designed to be portable, accurate, reliable, and simple model that is best suited for battery systems installed at telecom towers (BTS). It can be left unattended at sites for data collections (can later be exported for further analysis), or, by its integrated alarm feature which can assist the user/system (manual/auto) to manage the battery. TBM has been designed to monitor and log various battery parameters like individual cell voltages (up to 15v), current Under Voltage, Over Voltage of individual cells/battery and temperature at pre-dened intervals. System/Room temperature This system can be operated in charge, discharge, and oat Current imbalances modes. The system is equipped with the following modules: Loose connection between cells or battery strings Provides the following information for analysis through intelligent software in tabular and graphical forms State of charge of the battery Residual life of the battery Interruptions in mains power supply and battery usage Variations between cell voltages & string currents Transmits data to a remote or centralized control room through Ethernet/RS485/TCP Over-the-air Conguration facility provides remote management of the system Congurable query utility to search for historic data TBM module containing display and keypad for supervision. Web application for monitoring data at the set recording intervals and data storage. ® BATTERY MONITORING SYSTEMS SYSTEMS BATTERY MONITORING Technical Specication ABM TBMS 36 / 45 / 54 Cells 24 Cells 11520 Cells 24 Cells Cell and String voltage Cell and String voltage String current Yes (using CT) yes (using 75mV shunt) Voltage range No. of cell inputs per measurement module Max.no.of cells that can be monitored at a time Voltage monitoring 0 to 15 V per input 0 to 15 V per input Voltage accuracy 1% 1% Voltage resolution 100m V(on full range) 10mV (on full range) Current resolution 0.1A 0.1A Current accuracy 1% 1% Temperature resolution 1% 1% Temperature accuracy +/ - 1°C to 2°C +/ - 1°C to 2°C 5V DC, 1<100mA 36V- 72V DC Power consumption Operating temperature range <2.5W -40 to +85°C <2.5W -40 to +85°C Temperature measurement Ambient(One) Input Power supply Mounting Panel or wall mounting IP protection Up to three temp. Inputs Panel or wall mounting IP21 IP21 Type of sensing Electro-mechanical Electro-mechanical Scanning interval 60 Sec (minimum) 60 Sec (minimum) 2 KVA 2 KVA Isolation ® ® HBL Power Systems Limited 8-2-601, Road No 10, Banjara Hills Hyderabad 500034, TG, INDIA website : www.hbl.in e-mail : [email protected] corp.comm\01.dec.2011 Description