Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
List of vacuum tubes wikipedia , lookup
Photomultiplier wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Cavity magnetron wikipedia , lookup
32SB -1 00 KL32-1.0-100, KL KL32SB 32SB--1.0 1.0-1 -100 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 Description � KL32-1.0-100, KL32SB-1.0-100 Stationary X-Ray Tube has one focus. � The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode. � The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support. � Kailong product version adheres to international standards, e.g. CE and SFDA. Features and customer benefits � Elevated anode heat storage capacity and cooling � Constant high dose yield � Excellent lifetime Print NO.SA0027 2 Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 Technical Data Property Specification Type Standard KL32,KL32SB Nominal input power(1s DC) of the anode 4800W IEC 60613/1993 Anode heat storage capacity 31.5kJ IEC 60613 Maximum cooling capacity of the anode 300W Target angle (Ref: reference axis) X-ray tube and X-ray tube assembly IEC 60788 Tungsten Anode material Focal spot nominal value 15° Ref: Reference axis X-ray tube nominal voltage Max. Tube Current 1.0 IEC 60336/1993 100 kV IEC 60613 60mA DC IEC 60613 Filament Current 1.9A Max. Filament Voltage 3.9V Max. Filament Characteristics Permanent Filtration Weight Operation Limits Ambient temperature Relative humidity Barometric pressure Print NO.SA0027 Min. 0.8mm Al / 50 kV IEC60522/1999 285 g IEC 60613 Transport and Storage Limits From 10 °C to 40 °C From 30 % to 75 % From 700 hPa to 1060hPa 3 Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 OUTLINE DRAWING KL32-1.0-100 Print NO.SA0027 4 Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 KL32SB-1.0-100 Anode Thermal Characteristics 50 35 45 30 35 25 30 20 25 (kJs) Heat (kHUs) 40 20 15 15 10 10 5 5 0 Cooling 100W 200W 300W 0 0 1 2 3 4 5 6 7 8 9 10 Time (Min.) Maximum Rating Charts (Absolute maximum rating charts) Print NO.SA0027 5 Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 (DC) Emission & Filament Characteristics (AC) 14 4.5 4.3 4.1 3.9 10 Filament Voltage (V) Tube Current (mA) 12 3.7 3.5 3.3 8 6 4 2 0 1.6 1.7 1.8 Filament Current (A) Print NO.SA0027 6 40kV 60kV 3.1 2.9 80kV 2.7 2.5 100kV 1.9 Fila. Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 Cautions!!! X-ray tube will emit X–ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it. 1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube. When mounting tube inserts adopt proper caution, in order to avoid glass bulb breaking and fragments projection. Please use protective gloves and glasses. 2. Tube insert connected to H.V. supply is a radiation source: be sure to take all necessary safety cautions. 3. Wash thoroughly with alcohol the external surface of tube insert (care of fire risk). Avoid contact of dirty surfaces with cleaned tube insert. 4. Clamp system inside housing or self-contained units must not mechanically stress the tube. 5. After installation, check the right working of the tube (no fluctuation of tube current nor crackling). 6. Comply with insert thermal parameters, planning and programming the exposure parameters and cooling pauses. Housing or self-contained units must be provided with an adequate thermic protection. 7. Voltages indicated in charts are valid for transformer supplied with ground center. 8. It is extremely important to observe the connection diagram and the grid resistor value. Any change could modify the dimensions of the focal spot, also varying diagnostic performances or overloading anode target. 9. Tube inserts contain environment polluting materials, particularly lead liner tubes. Please apply to qualified operator for waste disposal, according to local regulation requirements. 10. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer. Print NO.SA0027 7 Release Date: 2012/6/14 2-1.0 -1 00, KL 32SB -1 00 KL3 KL32 1.0-1 -10 KL3 SB--1.0 1.0-1 -10 Notes • This high vacuum product is produced according to state-of-the–art technology. To prevent implosion please handle with care and use protective devices, e.g. glasses! • In the interest of complying with legal requirements concerning the environmental compatibility of our products (protection of natural resources, avoidance of waste) we endeavor to reuse components and to return them to the production cycle. We guarantee the functioning, quality and life of these components by taking extensive quality assurance measures, just as for factory-new components. The described product (s) is/are not commercially available. Content serves as preliminary information. The Kailong Medical Instrument Co Ltd., is ISO 9001 certified, manufactures in accordance with the Quality System Regulations (QSR) as defined by the Food and Drug Administration (FDA) and endeavors to comply with legal requirements concerning the environmental compatibility of its products. The reproduction, transmission or use of this document or its contents is not permitted without express written consent. Offenders will be liable for damages. Kailong reserves the right to modify the design and specifications contained herein without prior notice. All rights reserved, particularly in connection with patent applications or registrations of utility model or design. © Kailong Medical Instrument Co Ltd., For further information, please contact: Kailong Medical Instrument Co Ltd., Addres:6, No. 6 Road, Dongzhou Industrial Zone, Fuyang, Hangzhou, China 311401 Fax: +86571 87195003 http://www.kailongx-ray.com Print NO.SA0027 8 Release Date: 2012/6/14