Download Datasheet - Pump Centre

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Electrical substation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electric battery wikipedia , lookup

Current source wikipedia , lookup

Three-phase electric power wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Islanding wikipedia , lookup

Schmitt trigger wikipedia , lookup

Stray voltage wikipedia , lookup

Power inverter wikipedia , lookup

Uninterruptible power supply wikipedia , lookup

Rechargeable battery wikipedia , lookup

Surge protector wikipedia , lookup

Rectifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power electronics wikipedia , lookup

Voltage optimisation wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
WIMES 3.07
Page 20
APPENDIX C - DATA SHEETS
UNINTERRUPTIBLE POWER SUPPLIES
PROJECT TITLE (P)
PROJECT
REFERENCE
NUMBER (P)
PROJECT LOCATION (P)
UPS SUPPLIER (P/S)
DOCUMENT REFERENCE (P)
REVISION (P)
DATE (P)
REFERENCE
DRAWINGS
INCLUDED (Y/N) (P)
* - indicates Purchaser’s default requirement.
3.0 OPERATING ENVIRONMENT AND SITE
DETAILS
1
2
3
Operating Environment (P)
Site Location
Inland/coastal
Rural/urban/industrial
UPS Location ()
Inside (heated)
Inside (unheated)
Other (specify)
EMC Environment ()
1st environment – C1
1st environment – C2
2nd environment – C3
Deviations
From
Normal
Conditions (P)
Unusual
Environmental
Conditions (P)
4.0
ELECTRICAL
CHARACTERISTICS
SUPPLY
Service
Service
AND
4.2 Load Characteristics
1
Type of Load () (P)
PLC, SCADA,
instrumentation
Valve actuator
Other (specify)
PLC, SCADA, Instrumentation
Supply Details
(V, Hz, Ph, tolerances)
Current (A)
Power factor
Non Linear Load (Y/N)
Crest Factor
Valve Actuator
Supply Details
(V, Hz, Ph, tolerances)
Current Details (A)
Nominal operating
Maximum operating
Starting
Power Factor
Other Load Type(s) (Specify Details)
LOAD
4.1 Electrical Supply Characteristics
1
Voltage, Frequency and No. of Phases (P)
1
Voltage and Frequency Variations (+/- %)
(P)1
Voltage variation
Frequency variation
1 – If the UPS will be supplied from a diesel
generator, the relevant voltage and frequency
values shall be specified here.
ISSUE 4
NOVEMBER 2015
WIMES 3.07
5.0 PERFORMANCE SPECIFICATION
5.1 General
1
Service Life (Years) (P)
5.3 Electrical Characteristics
5.3.1 Input Characteristics
1
a
b
c
d
e
f
g
h
i
Input Characteristics (P/S)
Rated input voltage (V)
Rated input voltage
tolerance (%)
Rated input frequency
(Hz)
Rated input frequency
tolerance (%)
Number of phases
Rated input current (A)
Maximum
continuous
current (A)
THD (current) at rated
input current (%)
Input power factor
5.3.2 Output Characteristics
1
a
b
c
d
e
f
g
h
i
j
k
l
m
Output Characteristics (P/S)
Rated output voltage (V)
Rated output voltage
tolerance (%)
Rated output frequency
(Hz)
Rated output frequency
tolerance (%)
Number of phases
Rated output apparent
power (VA)
Rated output active
power (linear load) (W)
Rated output active
power (non-linear load)
(W)
Total voltage distortion
(linear load) (%)
Total voltage distortion
(non-linear load) (%)
Output fault clearing
capability
Overload capability
Range of load power
factor permitted
ISSUE 4
Page 21
5.3.3 Batter and Battery Charger Characteristics
1
a
b
b
c
d
Battery/Battery Charger
(P/S)
Battery rating (Ah)
Cell voltage (V)
Cell rating (Ah)
Stored energy time at
rated load (min)
Restored energy time
(to 90 % charge) (min)
Characteristics
5.4 Noise
1
Noise Levels (dB(A)) (P/S)
Maximum (70*) (P)
Actual (S)
5.5 Life Cycle Costs
5.5.1 Efficiency
1
Efficiency (P/S)
Minimum (90*) (P)
Actual (S)
5.5.2 Service Lives and Costs of Components
1
Expected Service Lives of Components
(P/S)
Life (x 103 hrs) (S)
Component (P)
Rectifier/charger
Battery
Inverter
2
Costs of Components (£)/Time Required
to Replace Components (mins) (S)
Component (specify)
Cost
Time
Rectifier/charger
Battery
Inverter
5.5.4 Availability
1
Availability (P/S)
Minimum (99.99*) (P)
Actual (S)
NOVEMBER 2015
WIMES 3.07
6.0 DESIGN SPECIFICATION
6.1 General
6.1.1 General
1
4
5
5
6
UPS Model Number (S)
IP Rating (IP 21*) (P)
Galvanic Isolation (P)
Required (Y/N)
Degree of Galvanic Isolation Required (P)
Page 22
6.4 Battery (contd.)
3
a
b
Maintenance
Bypass
Facility Required (Y/N)
(P)
c
6.1.2 Weights and Lifting Arrangements
1
Weights (kg) (S)
Weight of UPS
Heaviest maintenance
lift
6
6.1.4 O & M Manuals
1
Type Required/Provided () (P/S)
Purchaser’s standard
Supplier’s standard
6.2 Input Protection
1
Type of Protective Device (S)
1
Rating of Protective Device (A) (S)
6.3 Rectifier/Battery Charger
2
3
Charging Voltage to
Vary
with
Ambient
Temperature (Y/N) (P)
Charging Voltage to
Vary with Charge on
Battery (Y/N) (P)
6.4 Battery
2
2
7
Battery Details (S)
Cell/Monoblock Characteristics
Voltage (V)
Nominal capacity (Ah)
Cut-off voltage (V)
Cell/Monoblock Configuration
Serial String Configurations
Number of cells
Parallel String Configurations
Number of serial strings
Number of cells per
string
Battery Characteristics
Voltage (V)
Nominal Capacity (Ah)
Condition Monitoring System (P)
Required (Y/N)
Monitored Parameters () (P)
Battery temperature
Float current
Float voltage
AC/DC resistance
On-line
discharge
characteristics
Other (specify)
Location () (S)
In the UPS enclosure
In a separate enclosure
In separate racks
Other (specify)
6.5 Configuration and Protection of Outgoing
Circuits
1
Configuration and Protection of Outgoing
Circuits (P/S)
6.6 Communications
1
Type of Communications
Provided (P/S)
Required/
Battery Design Life at
20oC (Years) (P/S)
Battery to comply with
BS 6920 (Y/N) (P/S)
ISSUE 4
NOVEMBER 2015
WIMES 3.07
Page 23
6.7 Status Indications, Alarms and Telemetry
Outputs
1
Status Indications Required/Provided ()
(P/S)
Load on inverter
Load on battery
Battery
charge
remaining
1
Alarms Required/Provided () (P/S)
Load on bypass
Overload
Low/high output voltage
Inverter fault
Battery charger fault
Low battery voltage
Over temperature
2
Telemetry Outputs
() (P/S)
Common fault
Load on inverter
Load on bypass
Required/Provided2
2 – Indicate whether telemetry output is via a serial
data connection (SDC) or volt free change-over
contacts (VFC)
ISSUE 4
NOVEMBER 2015
WIMES 3.07
Page 24
APPENDIX D – SUPPLIER’S SUPPLEMENTARY DATA SHEET INFORMATION
Clause
ISSUE 4
Supplementary Information
NOVEMBER 2015