Download Progressive Multifocal Intraocular Lens G. P. Rubiolini

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Progressive Multifocal Intraocular Lens
G. Rubiolini M.D.
Italy
www.grvision.com
Disclosure of finanacial interest
Author's research is partially funded by Imperial Medical
Technologies (Cartersville GA, USA) producing, developing and
supplying the product presented
PURPOSE
This is the first clinical trial to evalutate safety long term visual
outcomes in a selected group of patient with cataract of this
"premium" IOL, available in two versions:
modified “C” style
Micro-Incision Plate style
“Progressive Multifocal” lens that uses a new optical geometry.
Materials and methods

35 patients (20 F ,15M. Mid age 56) had bilateral
Progressive Multi-Focal Intraocular Lenses implants
with a non-linear reading add from +3.0 Diopter to
+4.5(progressive)during cataract surgery (
PRESBIOPTICx by IMT, Cartersville GA USA). Exclusion
criteria included but was not limited to astigmatism
>1D, diabetic retinopathy, maculopathy and previous
ocular surgery.
Materials and methods


Biometry: IOLMaster
Zeiss
Target refraction:
emmetropia



Facochop procedure
(Stellaris B&L)
IOL implantation in
the capsular bag.
Injector : Medicel
VISCOJECTTM 2.2 mm
Materials and Methods
EIOLs characteristics
 Optic
6 mm
 Length
11 mm
(plate) 12 mm (cloop)
 AC Depth 5.3 mm
 A constant 118.4
 Sugested IOL
formula : Holladay


Biometry: IOLMaster Zeiss
Target refraction: emmetropia
PRESBIOPTICx
Modified “C”
PRESBIOPTICx
Micro Incision
Implanting
TM
PRESBIOPTICx
First Lens Implanted - If emmetropia & near vision
achieved then the second lens Implanted is identical.
• First Lens Implanted - If near vision is not
achieved then second lens can correct the problem.
•
DIOPTER
OPTICAL ADD
2nd Lens Availability
18.0D
+ 4.00
4.10D - 4.30D
19.0D
+ 3.80
3.90D – 4.10D
20.0D
+ 3.60
3.70D – 3.90D
21.0D
+ 3.40
3.50D – 3.70D
22.0D
+ 3.20
3.30D – 3.50D
23.0D
+ 3.00
3.10D – 3.30D
IOLs surfaces comparisons
PRESBIOPTICx
HP60CM
Imperial Medical
Technologies
Cartersville, GA
USA
Standard Multifocal
IOL
6
4
4
4
4
3
2
2
1
20D
20,5D
21 D
21,5D
22D
23D
23,5D
24D
25D
RESULTS: 12 to 24 months follow up

Total freedom from glasses was achieved in 28 patients
(>80%) with two similar near addition implants (Standard
PRESBIOPTICx).



5 patients received an extra 0.40D addition for the second
eye(Customized PRESBIOPTICx). Considering this group too, 33
patients (95%) achieved J2 best uncorrected near visual acuity
with bilateral vision.
100%of the patients achieved 20/25 or better uncorrected
visual acuity for distance.
2 Patients complained some temporary (2-3 months) night
vision problems such as glare, halos and sparkles (5,7%).
CONCLUSION



This revolutionary progressive addition system for
multifocal IOLs provides a excellent visual acuity for
distance and near and it can be eventually
customized.
Full range vision can be achieved in 95% of the
cases .
We found a significant reduction of temporary side
effects of multifocal IOLs such as glare, halos and
sparkles (5,7%).
Thank You