Download X4 Drives Specification Sheet

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Immunity-aware programming wikipedia , lookup

Power inverter wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Utility frequency wikipedia , lookup

Loudspeaker enclosure wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Power engineering wikipedia , lookup

Pulse-width modulation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical substation wikipedia , lookup

Ohm's law wikipedia , lookup

Rectifier wikipedia , lookup

Islanding wikipedia , lookup

Opto-isolator wikipedia , lookup

Current source wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electrical ballast wikipedia , lookup

Television standards conversion wikipedia , lookup

Fault tolerance wikipedia , lookup

Voltage regulator wikipedia , lookup

Stray voltage wikipedia , lookup

Three-phase electric power wikipedia , lookup

Surge protector wikipedia , lookup

Buck converter wikipedia , lookup

Distribution management system wikipedia , lookup

Power electronics wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Metadyne wikipedia , lookup

Stepper motor wikipedia , lookup

Mains electricity wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
X4 Rugged Drives
AC Drives for Harsh Environments
• 0.5 to 200HP
• NEMA 4X/IP66 and UL Type 3R enclosures
• Suitable for pressure washing
• Integrated brake resistor
• Easy-to-read display
• Standard Modbus communications
• ARCTIC mode for cold locations
• V/Hz or Sensorless Vector Control
• 3-year warranty
3-YEAR WARRANTY
X4 Series Drives are designed to keep driving in harsh
environments and are built from the ground up to survive
hostile conditions - and still be simple to set up and operate. They’re made to be mounted where the process is, not in
another enclosure or room that adds cost and space.
Integrated Brake Resistor Each X4 drive includes
Robust and Reliable The same enclosures that can
survive in the harsh industrial world makes them ideal
when cleanliness is extremely important, such as the Food
and Beverage industry where high pressure washings are
needed on a regular basis. The X4 drives, through 100 HP,
exceed the specifications of their rated UL Type 4X / IP66
Indoor and Outdoor rated enclosures, each being able to
withstand high pressure washdown of 1000 PSI from 12”
away. From 125HP through 200HP, the VACON X Series
can be placed outside in the elements with the new UL Type
3R, Indoor/Outdoor rating. That means every X4 drive can
be placed outside in the elements, allowing for even greater
mounting flexibility without having to spend even one cent
more on installation costs. The thick injected foam and metal
covers protect against bumps and misuse.
keypad which makes operation simple. The
easy-to-read display communicates operational
status information as well as parameter names
and settings in a clear, plain text, format making
navigation and programming easier than ever.
a Brake resistor, allowing it to better handle high
inertial loads right out of the box, and to stay warm
even in the coldest conditions.
Easy to Use The X4 drives features a user-friendly
• Simple intuitive programming with color coded
buttons
• Multi-language display – no codes to learn
• Two parameter levels for simple application
programming
• Application Macros make setup quick & easy
Simple and Flexible The X4 Series drives boast the easiest
programming and operation in the industry. The bright, clear,
backlit display provides an easy to read, customizable view
for operation and programming. The keypad has large, well
marked buttons to control all aspects of the drive operation
and programming. S-DRIVES-X4
X4 Rugged AC Drives
S-DRIVES-X4
ELECTRICAL SPECIFICATIONS
CONTROL
Rated Input Voltage:
200-230VAC ± 15%
1 - 25 HP
380-480VAC ± 15%
1 - 200 HP
575VAC ± 15%
1 - 200 HP
DC Holding / Injection Braking: At start, stop, by
frequency with adjustable current level and time or
continuous DC injection by digital input
Current Limit: Four-quadrant adjustable from 5 to
150%
Line Frequency: 50 / 60 Hz ± 2 Hz
Number of Phases: 3
Speed Ramps: Primary and alternate adjustable
from 0.1 to 3200.0 seconds
Source kVA (maximum): 10 times the unit rated kVA
(65kA max)
Voltage Boost: adjustable fixed boost or adjustable
auto boost
DC bus voltage
for:
230 Vac
models
460 Vac
models
575 Vac
models
Overvoltage trip
406 Vdc
814 Vdc
1017 Vdc
Dynamic brake activation
388 Vdc
776 Vdc
970 Vdc
Normal undervoltage
trip
199 Vdc
397 Vdc
497 Vdc
Control System: V/Hz or Sensorless Vector Control. Carrier frequency = 1 to 6 kHz programmable
Output Voltage: 0 to 100% of line voltage, 3 phase
Overload capacity:
120% of rated RMS current for 60 seconds (normal
duty rating)
150% of rated RMS current for 60 seconds (heavy
duty rating)
Frequency Ouput:
Range: 0.1 - 400Hz
Stability: 0.1 Hz, 0.1% analog over 24 hours ±10°C
ENVIRONMENTAL
Operating Temperature: -10°C to 40°C (14°F to
104°F)
Storage Temperature: -20°C to 65°C (-4°F to 149°F)
Altitude: Sea level to 3300 Feet [1000m] without
derating.
Humidity: 0% to 95% RH non-condensing.
Vibration: Per EN50178: Frame size 0 and 1 5G
Acoustic Noise: 80 dba sound power at 1 m (3 ft)
Cooling:
1 - 5 HP models - natural convection
7.5 - 200 HP: forced air
Agency Approvals: UL, cUL, CE
2
Voltage Characteristic: V/Hz - Linear, pump, fan or
2-piece linear; Sensorless Vector
Timed Overload: adjustable inverse time trip (shear
pin, 30 sec, 60 sec, 5 minutes) for standard or
inverter-duty motors
Communications: Modbus RTU RS-485 standard
PHYSICAL ATTRIBUTES
Mounting: Wall Mount: Thru-Hole or Panel Mount.
Enclosure Rating:
Type 4X (IP66) 0.5 to 100 HP
1000 psi water spray at 6 inches: 1 - 30 HP
1000 psi water spray at 12 inches: 1 - 100 HP
Type 3R (IP22) 125 to 200 HP
Construction: Steel Enclosure
PROTECTIVE FEATURES
Overvoltage fault
Overcurrent
Ground fault
Short circuit
Dynamic Brake overload
Drive temperature
Power wiring fault
Drive-timed overload
Input voltage quality
Overvoltage ridethrough
X4 Rugged AC Drives
S-DRIVES-X4
200-230V ±15% Three Phase
MOTOR SHAFT POWER AND CURRENT
High Overload (150%)
Low Overload (120%)
Model Number
HP
kW
X4-3--0010-2-N4
X4-3--0020-2-N4
X4-3--0030-2-N4
X4-3--0050-2-N4
X4-3--0075-2-N4
X4-3--0100-2-N4
X4-3--0150-2-N4
X4-3--0200-2-N4
X4-3--0250-2-N4
0.5 1 2 3 5 7.5 10 15 20 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 Amps
2.2 4.2 6.8 9.6 15.2 22 28 42 54 HP
kW
1 2 3 5 7.5 10 15 20 25 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 Amps
4.2 6.8 9.6 15.2 22 28 42 54 68 Dimensions
Frame
Size
W x H x D (in)
W x H x D (mm)
Weight (lbs)
Weight (kg)
F0 6.5 x 9.47 x 6.08
165 x 241 x 155
8.5
3.85
8.62 x 12.01 x 6.51
221 x 306 x 166
10.75 x 17.38 x 7.91
F2 273 x 442 x 201
11.19 x 20.19 x 11.73
F3 286 x 513 x 314
F1 14
6.35
29.5
13.38
50
22.68
380-460V ±15% Three Phase
MOTOR SHAFT POWER AND CURRENT
High Overload (150%)
Low Overload (120%)
Model Number
X4-3--0010-4-N4
X4-3--0020-4-N4
X4-3--0030-4-N4
X4-3--0050-4-N4
X4-3--0075-4-N4
X4-3--0100-4-N4
X4-3--0150-4-N4
X4-3--0200-4-N4
X4-3--0250-4-N4
X4-3--0300-4-N4
X4-3--0400-4-N4
X4-3--0500-4-N4
X4-3--0600-4-N4
X4-3--0705-4-N4
X4-3--1000-4-N4
X4-3--1250-4-3R
X4-3--1500-4-3R
X4-3--2000-4-3R
HP
kW
0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 Amps
1.1 2.1 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 180 HP
kW
1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 Amps
2.1 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 180 240 Dimensions
Frame
Size
W x H x D (in)
W x H x D (mm)
Weight (lbs)
Weight (kg)
F0 6.5 x 9.47 x 6.08
165 x 241 x 155
8.5
3.85
F1 8.62 x 12.01 x 6.51
221 x 306 x 166
14
6.35
F2 10.75 x 17.38 x 7.91
273 x 442 x 201
29.5
13.38
F3 11.19 x 20.19 x 11.73
286 x 513 x 314
50
22.68
F4 12.84 x 29.35 x 13.8
326 x 745 x 351
95
43.1
F5 18.14 x 52.5 x 16.88
461 x 1334 x 429
305
138.35
3
X4 Rugged AC Drives
S-DRIVES-X4
575V ±15% Three Phase
MOTOR SHAFT POWER AND CURRENT
High Overload (150%)
Low Overload (120%)
Model Number
X4-3--0010-5-N4
X4-3--0020-5-N4
X4-3--0030-5-N4
X4-3--0050-5-N4
X4-3--0075-5-N4
X4-3--0100-5-N4
X4-3--0150-5-N4
X4-3--0200-5-N4
X4-3--0250-5-N4
X4-3--0300-5-N4
X4-3--0400-5-N4
X4-3--0500-5-N4
X4-3--0600-5-N4
X4-3--0750-5-N4
X4-3--1000-5-N4
X4-3--1000-5-3R
X4-3--1000-5-3R
X4-3--1000-5-3R
HP
kW
0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 Amps
0.9 1.7 2.7 3.9 6.1 8 11 17 22 27 32 41 52 62 77 99 125 144 HP
kW
1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 Amps
1.7 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 144 192 Dimensions
Frame
Size
W x H x D (in)
W x H x D (mm)
Weight (lbs)
Weight (kg)
F1 8.62 x 12.01 x 6.51
221 x 306 x 166
14
6.35
F2 10.75 x 17.38 x 7.91
273 x 442 x 201
29.5
13.38
F3 11.19 x 20.19 x 11.73
286 x 513 x 314
50
22.68
F4 12.84 x 29.35 x 13.8
326 x 745 x 351
95
43.1
F5 18.14 x 52.5 x 16.88
461 x 1334 x 429
305
138.35
OPTIONS
XRKPM
XRKWM
XRKMK
XDBKITS4
XCBKITS5
Remote Keypad for Panel Mount Drives (Frame 0,1 & 2)
Remote Keypad for Wall Mount Drives (Frame 0,1 & 2)
Remote Keypad for Mounting Kit (Frame 3, 4 & 5)
DB Connection Kit - Frame 4
DB Connection Kit - Frame 5
The Company’s policy is one of continuous product
improvement and the right is reserved to modify the information
contained herein without notice.
Printed in USA August 2013
© MicroMod Automation & Controls, Inc. 2004
4
www.micromod.com
3 Townline Circle
Rochester, NY 14623-2537 USA
Tel: (585) 321-9200
Fax: (585) 321-9291
Email: [email protected]