Neurosurgical Prostheses Grouping Scheme and Benefits
**Suffixes legend and definitions are located at the end of this document
Groupings
04 - Neurosurgical
04.01 - ANEURYSM CLIPS
04.01.01 - Aneurysm Clip
Benefits
258
Complex
378
04.01.02 - AVM Clip
270
04.02 - DURA DEFECT REPAIR
04.02.01 - Repair, Graft, Small (≤10cm²)
72
Biological
360
04.02.02 - Repair, Graft, Medium (>10 to 50cm²)
472
Biological
545
04.02.03 - Repair, Graft, Large (>50 to 100cm²)
785
Biological
1120
04.02.04 - Repair, Graft, Extra Large (>100cm²)
655
Biological
1890
04.02.05 - Repair, Liquid Sealant (0 to 3ml)
800
04.02.06 - Repair, Liquid Sealant (>3 to 6ml)
835
04.02.07 - Repair, Self-Adhesive Membrane Sealant, Small (≤10cm²)
250
04.02.08 - Repair, Self-Adhesive Membrane Sealant, Medium (>10 to
50cm²)
560
04.02.09 - Repair, Self-Adhesive Membrane Sealant, Large (>50 to
100cm²)
April 2016
Groupings
Benefits
1020
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.01 - Valve, Externally Adjustable
2020
Antisyphon function, Coating, Distal catheter,
3310
catheter, Reservoir/Priming function
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.01 - Valve, Externally Adjustable
Antisyphon function, Coating, Distal catheter,
Reservoir/Priming function
Proximal
function
catheter,
Reservoir/Priming
Antisyphon function, Coating, Reservoir/Priming
2980
Antisyphon function, Distal catheter, Proximal
3200
Reservoir/Priming function
Antisyphon function, Distal catheter,
3055
Antisyphon function, Reservoir/Priming function
catheter,
3165
2870
Distal catheter, Lumboperitoneal, Proximal
3030
Reservoir/Priming function
Distal catheter, Proximal catheter,
Reservoir/Priming function
2700
Distal catheter, Reservoir/Priming function
2555
Lumboperitoneal, Reservoir/Priming function
2700
Reservoir/Priming function
2370
04.03.01.02 - Valve, Non-externally adjustable
1110
Proximal
Proximal
Antibiotics, Antisyphon function, Distal catheter,
2180
catheter, Reservoir/Priming function
Antibiotics, Distal catheter, Proximal catheter
1740
Antibiotics, Distal catheter, Proximal catheter,
Reservoir/Priming function
2090
Antisyphon function
1200
Antisyphon function, Coating, Distal catheter,
1990
catheter, Reservoir/Priming function
Antisyphon function, Coating, Distal catheter,
1845
April 2016
Groupings
Benefits
Reservoir/Priming function
function
catheter,
Reservoir/Priming
Antisyphon function, Coating, Reservoir/Priming
1660
Antisyphon function, Distal catheter, Proximal
1880
Reservoir/Priming function
Antisyphon function, Distal catheter,
1735
Antisyphon function, Lumboperitoneal
1530
Antisyphon function, Reservoir/Priming function
1550
Distal catheter, Lumboperitoneal
1625
Distal catheter, Proximal catheter
1440
Distal catheter, Proximal catheter,
Reservoir/Priming function
1790
Distal catheter, Reservoir/Priming function
1645
Lumboperitoneal
1440
Reservoir/Priming function
1460
04.03.01.03 - Valve and gravitational unit, externally adjustable
4040
Distal Catheter
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.03 - Valve and gravitational unit, externally adjustable
Distal Catheter, Reservoir/Priming Function
4225
4575
04.03.02 - Unitised shunt assembly, with proximal/distal catheter
450
Antisyphon function
1650
Reservoir/Priming function
900
Antibiotics
469
Antibiotics, Distal, Proximal
675
Distal
185
Distal, Coating
255
Proximal
185
Proximal, Coating
249
04.03.03 - Catheter
04.03.04 - Antisyphon Device
880
04.03.05 - Reservoir/Priming Device
April 2016
Groupings
Benefits
375
Integrated Catheter
560
04.03.06 - Shunt Attachment
04.03.06.01 - Connector
38
04.03.06.02 - Right Angled Guide
200
04.04 - DEEP BRAIN STIMULATION (DBS)
04.04.01 - Implantable Pulse Generator
04.04.01.01 - Primary Cell Pulse Generator (non-rechargeable)
9050
Dual Channel
04.04.01.02 - Rechargeable Pulse Generator
Dual Channel
Unlimited Deep Discharge Battery
15060
19150
22000
04.04.02 - External Components
04.04.02.01 - Patient Programmer
1400
04.04.02.02 - Recharger
1975
04.04.03 - Leads
04.04.03.01 - Permanent Lead
04.04 - DEEP BRAIN STIMULATION (DBS)
04.04.03 - Leads
04.04.03.01 - Permanent Lead
4150
04.04.03.02 - Lead Extension
2100
04.04.04 - Microtargetting Electrodes
1500
04.04.05 - Accessories
04.04.05.01 - Burr Hole Cover
550
04.04.05.02 - Connectors and cables
200
04.04.05.03 - Intraoperative accessories
175
04.05 - NEUROSTIMULATION THERAPIES FOR PAIN MANAGEMENT
04.05.01 - Pulse Generators
19150
April 2016
Groupings
Benefits
04.05.01.01 - Primary Cell Pulse Generator (non-rechargeable)
19150
Multi waveforms
24000
04.05.01.02 - Rechargeable Pulse Generator
19150
Adaptive Stimulation
Battery, 32
Stimulation
24000
Adaptive Stimulation, Unlimited Deep Discharge
26000
Electrode IPG
Integrated Leads
19980
Unlimited Deep Discharge Battery
22000
Unlimited Deep Discharge Battery, 10kHz
26000
04.05.01.03 - Radio Frequency System
9450
Dual Channel
12450
04.05.02 - External Components
04.05.02.01 - Patient Programmer
1500
04.05.02.02 - Patient Programmer Antenna
178
04.05.02.03 - On/Off switching device
1346
04.05.02.04 - Recharger
1346
04.05.03 - Leads
04.05.03.01 - Permanent Lead
04.05 - NEUROSTIMULATION THERAPIES FOR PAIN MANAGEMENT
04.05.03 - Leads
04.05.03.01 - Permanent Lead
≥32 electrodes
12200
>8 and <32 electrodes
7640
4 electrodes
3400
8 electrodes
4230
04.05.03.02 - Trial Lead
485
04.05.04 - Lead Extension
1510
04.05.05 - Accessories
04.05.05.01 - Revision Kits
545
April 2016
Groupings
Benefits
04.05.05.02 - Plug
168
04.05.05.03 - Intraoperative Accessories
168
04.05.05.04 - Lead Delivery System
730
04.05.05.05 - Connectors and Cables
200
04.06 - INTRATHECAL DRUG DELIVERY SYSTEM
04.06.01 - Implantable Infusion Pump
Fixed Flow Rate
9300
Variable Flow Rate
16250
04.06.02 - Patient Programmer
1500
04.06.03 - Intrathecal Catheter
04.06.03.01 - One piece
500
04.06.03.02 - Two piece
1100
Reinforced
1100
04.06.04 - Accessories
04.06.04.01 - Revision Kit
600
04.06.04.02 - Refill/Catheter Access Kits
40
04.07 - NEUROSTIMULATION THERAPIES FOR SEIZURE CONTROL
04.07.01 - Vagal nerve stimulators
04.07.01.01 - Implantable pulse generator
04.07 - NEUROSTIMULATION THERAPIES FOR SEIZURE CONTROL
04.07.01 - Vagal nerve stimulators
04.07.01.01 - Implantable pulse generator
12670
04.07.01.02 - Lead
3400
04.08 - NEURO INTERVENTION
04.08.01 - Stent
7500
04.08.02 - Coils
1505
April 2016
Groupings
Benefits
04.08.03 - Assist Devices
04.08.03.01 - Catheters
700
04.08.03.02 - Coil detachment device
350
04.08.03.03 - Guidewire
680
04.08.03.04 - Vascular embolisation balloon
1727
04.08.04 - Intrasaccular flow diverter
9030
04.09 - Intracranial Pressure (ICP) Monitoring
04.09.01 - Transducer
Catheter
1300
Skull Bolt
1050
04.10 - Cerebrospinal Fluid (CSF) Diversion
04.10.01 - External Ventricular Drain
185
04.10.02 - External Lumbar Drainage
300
Suffixes:
DE: Device electronically receives and stores intermittent or continuous glucose information
from an external or integral/attached device
RT: System can transmit real-time data or alerts to third party devices or systems (eg. digital
telephone network or internet)
SS: System includes software which allows downloading and analysis of information
OTS: Over the Scope
Definitions:
Absorbable Oil Coating
Absorbable
Abutment
Adaptive Stimulation
Adhesion Prevention
Anatomically Conforming
Angled/Offset
Coating which minimises tissue attachment and foreign body
reaction and inflammation
Capable of being absorbed
Connection between the sound processor and implant (fixture)
Senses patient body position and adjusts stimulation
accordingly
Product minimises the likelihood of adhesions
Conforms to body shape
The Angled/offset abutment is used to compensate for the
angle of the implant when inserted into the jaw
April 2016
Antibiotic
Antimicrobial
Antisyphon function
Articulating/Roticulating
Assembly
Biological
Biomodelled
Bioresorbable
Bolus
Burr
Coated
Coating
Complex
Compression
Connectors and Cables
Deep Discharge Battery
Delivery System
Distractor
Doppler Guided
Dual Channel
Dual Mesh
Dual Plate
Electroacoustic
Endoscopic
Expander Implant
Extra-tracheal
Fixation Plate
Fixed Flow Rate
Fixture
Flanged
Generation 3
Generation 4
Hemimandible
Integrated Delivery System
Intraoperative accessories
Intra-tracheal
Laparoscopic Extender
Contains or is covered with an antibiotic to prevent infection
Substance that kills or inhibits the growth of micro-organisms
Prevents unwanted drainage or transfer of a liquid
Having joints or jointed segments and able to rotate the head of
the device around the central axis
A product made up of multiple components
Made from tissue harvested from animals or human cadavers
Patient specific prosthesis usually manufactured using 3
dimensional scans and manufacturing technology
Item breaks down and is absorbed/resorbed by the body and
expelled through one of the body's systems
A large volume of fluid or drug dose given intravenously and
rapidly at one time
Burr hole covering plate
A coating that minimises the likelihood of adhesions
A coating that minimises the likelihood of adhesions
Composed of many interconnected parts
Device features intrinsic capacity to apply compression force
Single use products integral to connecting components of
neurostimulation systems
Allows frequent discharge to zero volts without causing early
battery failure
A means or technology or device for administering drug or
treatment
Surgical instrument or apparatus used for bone development
Use of a doppler to identify veins during a surgical procedure
A system with the ability to simultaneously deliver two different
levels of stimulation
Combination of absorbable and non-absorbalbe fibres
Consisting of more that one plate
Use of a hearing aid and Cochlear Implant together. The
hearing aid acoustically magnifies low frequencies, whilst the
Cochlear electronically stimulates middle and high frequencies
A general term for minimally invasive surgery (MIS) or,
specifically, MIS where the device is inserted via a natural body
opening
Implant which is able to be expanded
Outside the trachea
A plate used to stabilise fractures
The drug delivery flow rate is fixed at manufacture and is nonadjustable
Bone anchored implant
Having an external or internal ridge
Technological advance of the product
Technological advance of the product
Half of the mandible
The implantable device is provided pre-loaded into the related
delivery system
Single use products integral to implanting a device
Inside the trachea
A device designed to provide an extension of reach duirng
laparoscopic surgery
April 2016
Laparoscopic
Locking
Maxilla
Multiple Chamber
Multivector
Nitinol
On/Off switching device
Patient Programmer
Polymer
Pre-shaped
Programmable
Reinforced
Resorbable
Resorbable
Revision kit
Self Expanding
Self Expanding
Self-fixating
Silicone
Single Vector
Symphsis
Synthetic
Textured
Valved
Variable Flow Rate
Minimally invasive surgery where the device is inserted via a
trocar through a surgical incision (key hole surgery)
Ability to lock the plate as the screws are tightened
The upper jaw
Consisting of at least two compartments
Modular system that can be adapted to achieve a wide range of
clinical results
Made from nickel titanium alloy
A device provided to the patient to switch the pulse generator
on and off
A device provided to the patient to self-modulate a drug delivery
or impulse generator system
Comprises of polyethylene
Having a predetermined width, height and projection
Able to be programmed
Wall reinforcement to improve strength, durability and resist
kinking
Can be broken down and assimilated back into the body
Item breaks down and is absorbed/resorbed by the body and
expelled through one of the body's systems
Single use products integral to revising an implanted system
Auto inflating using osmosis
Compressed stents which expands automatically
Enables positioning and secure placement without the need for
sutures
A synthetic compound
A subcutaneous ramus lengthening distractor
Intermandibular joint
A substance or material produced by chemical processes and
not occurring naturally
Coating having different types of irregularities or rugasity
Having a valve
The drug delivery flow rate is able to be adjusted dependent on
clinician preferences and patient needs