Laser Particle Counter - LasPaC ll Technical Data Introduction Working Conditions The STAUFF Laser Particle Counter LasPaC II is a twin-laser, microprocessor-controlled, 8-channel particle counter designed for monitoring the degree of contamination of mineral based hydraulic fluids. Operating temperature: +5°C ... +80°C (+41°F ... +176°F) Data Output Cumulative particle counts, as well as cleanliness classes according to ISO 4406 (1999) / SAE AS 4059 Rev.D (2001) and ISO 4406 (1991) / NAS 1638 (1964) Laser Sensors The LasPaC II is equipped with two laser sensors: • A high accuracy laser for 4-6 µm • A standard accuracy laser for 6-68 µm Integrated printer Enables printouts and documentation in the field. Fixed head thermal printer 384 dots per line. Measured channels: 4, 6, 14, 21, 25, 38, 50, 68 µm The orifice of the sensor has a cross section 0,9 x 0,9 mm (0,036 x 0,036 inch). Integrated memory 600 standard measurements DIAGTRONICS The maximum concentration is ISO 4406 Code 24 (160.000 p/ml). Computer interface RS232 communication port as standard, RS485 on request (only for LasPaC II – I) USB adaptor available Calibration The sensor is calibrated with ISO-Medium Test Dust (MTD, according to ISO 11171:1999) providing results according to ISO 4406, SAE AS 4059 and NAS 1638. Software Downloading and storage of the data with included software. Further processing with Microsoft Excel® possible. Fluid Compatibility Mineral oil and petroleum based fluids (Phosphate ester and Skydrol compatible devices on request) Dimensions Pressure and Viscosity Pressure range: Viscosity range: 2 ... 420 bar (29 ... 6000 PSI) viscosity up to 400 cSt LasPaC II Portable LasPaC II Mobile LasPaC II Inline Dimensions 551x358x226 mm 340x295x152 mm 120x275x250 mm (W x D x H) (21.7x14.1x8.9 inch)(3.4x11.6x5.9 inch)(4.72x10.83x9.84 inch) Weight Accuracy / Repeatability 13 kg (28.66 lbs) 4,75kg (10.47 lbs) 4,8kg (10.58 lbs) Better than 3% typical, also for moisture / temperature sensor Moisture / Temperature Sensor Test coupling STAUFF Test 20 (M16x2) Moisture results as relative humidity (RH %), Temperatures in ˚C Power Supply Bottle Sampler Connections Voltage range: 110 V ... 240 V AC 12 V ... 24 V DC 110 ml version only for mineral oil applications 250 ml version for mineral oil applications. Phosphate ester units on request. UK, EU, US power supply available All devices with de-aeration facility. Number of tests before recharging is required: 100 tests D68 Laser Particle Counter - LasPaC ll Technical Data Technical Data Devices Dimension LasPaC II – P LasPaC II – M LasPaC II - I 551x358x226 mm (21.7x14.1x8.9 inch) 340x295x152 mm (3.4x11.6x5.9 inch) 120x275x250 mm (4.72x10.83x9.84 inch) Weight 13 kg (28.66 lbs) Keyboard QWERTY keyboard integrated No keyboard No keyboard Printer Thermal printer (integrated) 384 dots/line No printer No printer 1 to 400 cSt 1 to 400 cSt 1 to 400 cSt MTD, ISO 11171:1999 MTD, ISO 11171:1999 MTD, ISO 11171:1999 Viscosity Range Analysis Range Sensitivity Sample Volume ISO 8-24, ISO 4406 Code, NAS1638 ISO 8-24, ISO 4406 Code, NAS1638 ISO 8-24, ISO 4406 Code, NAS1638 code 2-12, SAE AS 4059 Code 2-12 code 2-12, SAE AS 4059 Code 2-12 code 2-12, SAE AS 4059 Code 2-12 > 4,6,14,21,25,38,50,68 µm 8 ml (short), 15 ml (normal), 30 ml (dynamic), 24 ml (bottle sampler), 15 ml (continuous) > 4,6,14,21,25,38,50,68 µm 8 ml (short), 15 ml (normal), 30 ml (dynamic), 24 ml (bottle sampler), 15 ml (continuous) 2 ... 420 bar (29 ... 6000 PSI) 2 ... 420 bar (29 ... 6000 PSI) Pressure Range Operating Temperature Max. Concentration +5...+80°C (+41°F...+ 176°F) > 4,6,14,21,25,38,50,68 µm 15 ml 2...420 bar (29...6000 PSI) (Series 30) 10...420 bar (145...6000 PSI) (Series 31) +5...+80°C +5...+80°C (+41°F...+ 176°F) (+41°F...+ 176°F) ISO 24 ISO 24 ISO 24 Power Supply 110 / 240 V AC 12 / 24 V DC 110 / 240 V AC 12 / 24 V DC 110 / 240 V AC 12 / 24 V DC Accumulator Internal rechargeable battery External battery pack (optional) n/a Data Storage 600 tests 600 tests 600 tests Fluid Compatibility Mineral oil/ petroleum based fluids,Mineral oil/ petroleum based fluids, Mineral oil/ petroleum based fluids, (phosphatester and water glycol (phosphatester and water glycol (phosphatester and water glycol on request) on request) on request) Computer Interface External Alarm Hose Connections Accessories RS232 RS232 RS 232, RS485 on request External alarm socket External alarm socket Signal in connector cable STAUFF-Test 20 M16x2 STAUFF-Test 20 M16x2 STAUFF-Test 20 M16x2 W-Moisture sensor with W-Moisture sensor with temperature function temperature function Bottle sampler 110 ml / 250 ml Bottle sampler 110 ml / 250 ml Screen filter 500 micron Screen filter 500 micron D69 W-Moisture sensor with temperature function Bottle sampler 110 ml / 250 ml Screen filter 500 micron DIAGTRONICS Calibration 4,75kg (10.47 lbs) 4,8kg (10.58 lbs)