Laser Particle Counter - LasPaC ll Technical Data
Introduction
Working Conditions
The STAUFF Laser Particle Counter LasPaC II is a
twin-laser, microprocessor-controlled, 8-channel particle counter designed for monitoring the degree of contamination of mineral based hydraulic fluids.
Operating temperature:
+5°C ... +80°C (+41°F ... +176°F)
Data Output
Cumulative particle counts, as well as cleanliness classes according to ISO 4406 (1999) / SAE AS 4059 Rev.D
(2001) and ISO 4406 (1991) / NAS 1638 (1964)
Laser Sensors
The LasPaC II is equipped with two laser sensors:
• A high accuracy laser for 4-6 µm
• A standard accuracy laser for 6-68 µm
Integrated printer
Enables printouts and documentation in the field.
Fixed head thermal printer 384 dots per line.
Measured channels: 4, 6, 14, 21, 25, 38, 50, 68 µm
The orifice of the sensor has a cross section 0,9 x 0,9
mm (0,036 x 0,036 inch).
Integrated memory
600 standard measurements
DIAGTRONICS
The maximum concentration is ISO 4406 Code 24
(160.000 p/ml).
Computer interface
RS232 communication port as standard,
RS485 on request (only for LasPaC II – I)
USB adaptor available
Calibration
The sensor is calibrated with ISO-Medium Test Dust
(MTD, according to ISO 11171:1999) providing results
according to ISO 4406, SAE AS 4059 and NAS 1638.
Software
Downloading and storage of the data with included software.
Further processing with Microsoft Excel® possible.
Fluid Compatibility
Mineral oil and petroleum based fluids
(Phosphate ester and Skydrol compatible devices on request)
Dimensions
Pressure and Viscosity
Pressure range:
Viscosity range: 2 ... 420 bar (29 ... 6000 PSI)
viscosity up to 400 cSt
LasPaC II Portable
LasPaC II
Mobile
LasPaC II
Inline
Dimensions 551x358x226 mm 340x295x152 mm 120x275x250 mm
(W x D x H) (21.7x14.1x8.9 inch)(3.4x11.6x5.9 inch)(4.72x10.83x9.84 inch)
Weight Accuracy / Repeatability
13 kg (28.66 lbs)
4,75kg
(10.47 lbs)
4,8kg
(10.58 lbs)
Better than 3% typical, also for moisture / temperature sensor
Moisture / Temperature Sensor
Test coupling STAUFF Test 20 (M16x2)
Moisture results as relative humidity (RH %), Temperatures in ˚C
Power Supply
Bottle Sampler
Connections
Voltage range: 110 V ... 240 V AC
12 V ... 24 V DC
110 ml version only for mineral oil applications
250 ml version for mineral oil applications.
Phosphate ester units on request.
UK, EU, US power supply available
All devices with de-aeration facility.
Number of tests before
recharging is required: 100 tests
­D68
Laser Particle Counter - LasPaC ll Technical Data
Technical Data
Devices Dimension
LasPaC II – P LasPaC II – M LasPaC II - I
551x358x226 mm
(21.7x14.1x8.9 inch)
340x295x152 mm
(3.4x11.6x5.9 inch)
120x275x250 mm
(4.72x10.83x9.84 inch)
Weight 13 kg (28.66 lbs) Keyboard QWERTY keyboard integrated No keyboard No keyboard
Printer Thermal printer (integrated)
384 dots/line No printer
No printer
1 to 400 cSt 1 to 400 cSt 1 to 400 cSt
MTD, ISO 11171:1999 MTD, ISO 11171:1999 MTD, ISO 11171:1999
Viscosity Range Analysis Range Sensitivity
Sample Volume
ISO 8-24, ISO 4406 Code, NAS1638 ISO 8-24, ISO 4406 Code, NAS1638 ISO 8-24, ISO 4406 Code, NAS1638
code 2-12, SAE AS 4059 Code 2-12 code 2-12, SAE AS 4059 Code 2-12 code 2-12, SAE AS 4059 Code 2-12
> 4,6,14,21,25,38,50,68 µm 8 ml (short), 15 ml (normal),
30 ml (dynamic), 24 ml (bottle sampler),
15 ml (continuous)
> 4,6,14,21,25,38,50,68 µm 8 ml (short), 15 ml (normal),
30 ml (dynamic),
24 ml (bottle sampler),
15 ml (continuous)
2 ... 420 bar (29 ... 6000 PSI) 2 ... 420 bar (29 ... 6000 PSI) Pressure Range Operating
Temperature Max. Concentration +5...+80°C (+41°F...+ 176°F) > 4,6,14,21,25,38,50,68 µm
15 ml
2...420 bar (29...6000 PSI)
(Series 30)
10...420 bar (145...6000 PSI)
(Series 31)
+5...+80°C
+5...+80°C
(+41°F...+ 176°F) (+41°F...+ 176°F)
ISO 24 ISO 24 ISO 24
Power Supply 110 / 240 V AC
12 / 24 V DC
110 / 240 V AC
12 / 24 V DC
110 / 240 V AC
12 / 24 V DC
Accumulator Internal rechargeable battery External battery pack (optional) n/a
Data Storage 600 tests 600 tests 600 tests
Fluid Compatibility Mineral oil/ petroleum based fluids,Mineral oil/ petroleum based fluids, Mineral oil/ petroleum based fluids,
(phosphatester and water glycol (phosphatester and water glycol (phosphatester and water glycol
on request)
on request)
on request)
Computer Interface External Alarm Hose Connections Accessories RS232 RS232 RS 232, RS485 on request
External alarm socket External alarm socket Signal in connector cable
STAUFF-Test 20 M16x2 STAUFF-Test 20 M16x2 STAUFF-Test 20 M16x2
W-Moisture sensor with
W-Moisture sensor with
temperature function
temperature function
Bottle sampler 110 ml / 250 ml Bottle sampler 110 ml / 250 ml Screen filter 500 micron Screen filter 500 micron ­D69
W-Moisture sensor with
temperature function
Bottle sampler 110 ml / 250 ml
Screen filter 500 micron
DIAGTRONICS
Calibration 4,75kg (10.47 lbs) 4,8kg (10.58 lbs)