The Internet and Its Uses
... –The source device accomplishes this by comparing the source and destination addresses against the subnet mask. –Once the destination address has been determined to be on a remote network, the source device has to identify where it needs to forward the packet to reach the destination device. –The so ...
... –The source device accomplishes this by comparing the source and destination addresses against the subnet mask. –Once the destination address has been determined to be on a remote network, the source device has to identify where it needs to forward the packet to reach the destination device. –The so ...
9.4.2 CSMA/CD – The Process
... the receive circuit to the incoming data and then discard the 8 bytes. Ethernet implementations with throughput of 100 Mbps and higher are synchronous. Synchronous communication in this context means that the timing information is not required. ...
... the receive circuit to the incoming data and then discard the 8 bytes. Ethernet implementations with throughput of 100 Mbps and higher are synchronous. Synchronous communication in this context means that the timing information is not required. ...
OmniSwitch 9900 Modular LAN chassis
... from 40 GigE, 1/10 GigE, 1/10GBase-T and 10/100/1000Base-T. The chassis management module has built-in 2x 40 GbE ports; each port can also be used as 4x 1/10 GbE with splitter cables. The OmniSwitch 9900 supports 1+1 redundant and hot-swappable power supplies. The power supply units are internal but ...
... from 40 GigE, 1/10 GigE, 1/10GBase-T and 10/100/1000Base-T. The chassis management module has built-in 2x 40 GbE ports; each port can also be used as 4x 1/10 GbE with splitter cables. The OmniSwitch 9900 supports 1+1 redundant and hot-swappable power supplies. The power supply units are internal but ...
What is Cisco Remote-PHY Solution
... In the emerging markets, most triple-play consumers live in multi-tenant buildings (referred to as Multi Dwelling Units or MDU) with the number of residents usually being less than 500 residents per building or cluster. These buildings are typically served by fiber with one of several “final 100 met ...
... In the emerging markets, most triple-play consumers live in multi-tenant buildings (referred to as Multi Dwelling Units or MDU) with the number of residents usually being less than 500 residents per building or cluster. These buildings are typically served by fiber with one of several “final 100 met ...
User Manual Broadband Blaster DSL Ethernet/USB 8012U
... Software. Nor may you sub-license any of your rights under this Agreement. You may use the Software for your personal use only, and not for public performance or for the creation of publicly displayed videotapes. 10.Decompiling, Disassembling, or Reverse Engineering You acknowledge that the Software ...
... Software. Nor may you sub-license any of your rights under this Agreement. You may use the Software for your personal use only, and not for public performance or for the creation of publicly displayed videotapes. 10.Decompiling, Disassembling, or Reverse Engineering You acknowledge that the Software ...
Cisco VG200: Cisco IP Telephony Voice Gateway
... NOTE: The VG200 is designed and validated strictly for Cisco AVVID CallManager environments only. It is not intended, tested or supported for applications such as H.323 toll bypass or as a SIP GW. The Cisco VG200 Voice-over-IP (VoIP) Gateway is a next-generation voice-conversion device that provides ...
... NOTE: The VG200 is designed and validated strictly for Cisco AVVID CallManager environments only. It is not intended, tested or supported for applications such as H.323 toll bypass or as a SIP GW. The Cisco VG200 Voice-over-IP (VoIP) Gateway is a next-generation voice-conversion device that provides ...
broadband business - Andatelecomindia.com
... relevant international standards related to safety and electromagnetic radiation and immunity. Following list of standards is applicable to all the access equipment mentioned in this catalogue. A short explanation of each of them can be found in the reference section. The table below only mentions t ...
... relevant international standards related to safety and electromagnetic radiation and immunity. Following list of standards is applicable to all the access equipment mentioned in this catalogue. A short explanation of each of them can be found in the reference section. The table below only mentions t ...
Cisco ONS 15305 Multiservice Provisioning Platform for SDH Access Networks
... 15305 CPE, as well as directly connected customer TDM or data traffic from electrical interfaces. The Cisco ONS 15305 can be deployed in many configurations: as an add/drop multiplexer, as a terminal multiplexer, as an STM-4/STM-16 cross-connect (non-blocking 64x64 STM-1 matrix at the VC-4/3/12 leve ...
... 15305 CPE, as well as directly connected customer TDM or data traffic from electrical interfaces. The Cisco ONS 15305 can be deployed in many configurations: as an add/drop multiplexer, as a terminal multiplexer, as an STM-4/STM-16 cross-connect (non-blocking 64x64 STM-1 matrix at the VC-4/3/12 leve ...
Cisco 827 Router Cabling and Setup Quick Start Guide
... When you first launch the CD, you will notice a list of books in the left pane of your display that you can use to navigate directly to the book you want to view. When you select the document, Acrobat Reader opens the book in .pdf format and provides a list of topics in the left frame of the Acrobat ...
... When you first launch the CD, you will notice a list of books in the left pane of your display that you can use to navigate directly to the book you want to view. When you select the document, Acrobat Reader opens the book in .pdf format and provides a list of topics in the left frame of the Acrobat ...
Leading Networking Solutions for Industrial
... industry with leading Ethernet networking technology and sets the standards for quality, reliability and service. Robust Hirschmann’s years as a networking leader and pioneer, the use of premium electronic components and effective (fan-less) thermal management translates to superior performance and ...
... industry with leading Ethernet networking technology and sets the standards for quality, reliability and service. Robust Hirschmann’s years as a networking leader and pioneer, the use of premium electronic components and effective (fan-less) thermal management translates to superior performance and ...
BreezeMAX PRO 5000 CPE
... The instrument transmits radio energy during normal operation. To avoid possible harmful exposure to this energy, do not stand or work for extended periods of time in front of its antenna. The long-term characteristics or the possible physiological effects of radio frequency electromagnetic fields h ...
... The instrument transmits radio energy during normal operation. To avoid possible harmful exposure to this energy, do not stand or work for extended periods of time in front of its antenna. The long-term characteristics or the possible physiological effects of radio frequency electromagnetic fields h ...
ST Micro Connect 2 host-target interface
... shared among users. This datasheet assumes that the user is reasonably familiar with the concepts and terms involved with TCP/IP networking. In USB mode using the USB Type B connector, the ST Micro Connect 2 has full plug-and-play, auto-configure capability. A USB 2.0 type A connector provides expan ...
... shared among users. This datasheet assumes that the user is reasonably familiar with the concepts and terms involved with TCP/IP networking. In USB mode using the USB Type B connector, the ST Micro Connect 2 has full plug-and-play, auto-configure capability. A USB 2.0 type A connector provides expan ...
63966-CMTS Overview - Cisco Support Community
... The PRE performs all Layer 2 and Layer 3 packet routing and forwarding. PRE modules support redundant operation when installing two PRE modules in a Cisco uBR10012 chassis. If the active PRE fails, the standby PRE automatically takes over operation of the chassis. ...
... The PRE performs all Layer 2 and Layer 3 packet routing and forwarding. PRE modules support redundant operation when installing two PRE modules in a Cisco uBR10012 chassis. If the active PRE fails, the standby PRE automatically takes over operation of the chassis. ...
Introduction to Computer Networks
... The 802.5 standard includes a specification for an optional priority mechanism. Eight levels of priority are supported by providing two 3-bit fields in each data frame and token: a priority field and a reservation field. P(f): priority of frame P(s): service priority; priority of current token R(s): ...
... The 802.5 standard includes a specification for an optional priority mechanism. Eight levels of priority are supported by providing two 3-bit fields in each data frame and token: a priority field and a reservation field. P(f): priority of frame P(s): service priority; priority of current token R(s): ...
1769-SG001 - Literature Library
... (2) Contact the Rockwell Automation specialty products group for availability. ...
... (2) Contact the Rockwell Automation specialty products group for availability. ...
ug_niosedk.pdf
... specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the property of their respect ...
... specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the property of their respect ...
PDF
... http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, the Cisco logo, DCE, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service ...
... http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, the Cisco logo, DCE, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service ...
How to connect an Epson POS printer with
... Select the printer and press Configuration to view or change settings. (Pressing the Launch Browser button will contact the TMNet WebConfig interface using your web browser.) ...
... Select the printer and press Configuration to view or change settings. (Pressing the Launch Browser button will contact the TMNet WebConfig interface using your web browser.) ...
HUAWEI S5320-EI Switch Datasheet
... in a VLAN. Interfaces in a subordinate separate VLAN can communicate with ports in the principal VLAN but cannot communicate with each other. MUX VLAN is usually used on an enterprise intranet to isolate user interfaces from each other but allow them to communicate with server interfaces. This funct ...
... in a VLAN. Interfaces in a subordinate separate VLAN can communicate with ports in the principal VLAN but cannot communicate with each other. MUX VLAN is usually used on an enterprise intranet to isolate user interfaces from each other but allow them to communicate with server interfaces. This funct ...
Campuswide VLAN
... Campuswide VLANs • Users are Members of a specific VLAN (Subnet) independent of physical moves • Each VLAN could have a common set of security requirements for all members • Today most traffic is local to VLAN With wirespeed L3 Performance no longer required ...
... Campuswide VLANs • Users are Members of a specific VLAN (Subnet) independent of physical moves • Each VLAN could have a common set of security requirements for all members • Today most traffic is local to VLAN With wirespeed L3 Performance no longer required ...
Chapter6
... • Using subinterfaces for inter-VLAN routing results in a less complex physical configuration (less cables) than using separate physical interfaces. • On the other hand, using subinterfaces with a trunk port results in a more complex software configuration, which can be difficult to troubleshoot. • ...
... • Using subinterfaces for inter-VLAN routing results in a less complex physical configuration (less cables) than using separate physical interfaces. • On the other hand, using subinterfaces with a trunk port results in a more complex software configuration, which can be difficult to troubleshoot. • ...
Ethernet and Legacy Access over DSL
... • EFM bonding - enables each link to synch at different rate. Failure or addition ...
... • EFM bonding - enables each link to synch at different rate. Failure or addition ...
OmniSwitch 6900 Stackable LAN Switches - Alcatel
... switches. All models are 1RU form factor with redundant power supplies and fan trays for front-to-back and back-to-front airflow. A wide range of Ethernet and Fibre Channel interfaces are supported. Available interfaces include 40 GigE, 1/10 GigE, 1/10GBase-T, 100Base-T, and 2/4/8GigFC in the base s ...
... switches. All models are 1RU form factor with redundant power supplies and fan trays for front-to-back and back-to-front airflow. A wide range of Ethernet and Fibre Channel interfaces are supported. Available interfaces include 40 GigE, 1/10 GigE, 1/10GBase-T, 100Base-T, and 2/4/8GigFC in the base s ...
FTTx PON Guide Testing Passive Optical Networks
... rapid deployment of new telecommunications technology. The International Telecommunications Union (ITU-T) turned FSAN specifications into recommendations. The FSAN specification for ATM-based PONs became an international standard in 1998 and was adopted by the ITU as recommendation G.983.1. In 2001, ...
... rapid deployment of new telecommunications technology. The International Telecommunications Union (ITU-T) turned FSAN specifications into recommendations. The FSAN specification for ATM-based PONs became an international standard in 1998 and was adopted by the ITU as recommendation G.983.1. In 2001, ...
Industrial Ethernet Switches
... The network and automation components of SIMATIC NET are part of Totally Integrated Automation (TIA), an integrated range of products and systems for automation in all areas – from incoming goods, through the production process to outgoing goods, and from the field level, through to the connection t ...
... The network and automation components of SIMATIC NET are part of Totally Integrated Automation (TIA), an integrated range of products and systems for automation in all areas – from incoming goods, through the production process to outgoing goods, and from the field level, through to the connection t ...
Registered jack
A Registered Jack (RJ) is a standardized telecommunication network interface for connecting voice and data equipment to a service provided by a local exchange carrier or long distance carrier. Registration interfaces were first defined in the Universal Service Ordering Code (USOC) system of the Bell System in the United States for complying with the registration program for customer-supplied telephone equipment mandated by the Federal Communications Commission (FCC) in the 1970s. They were subsequently codified in the Code of Federal Regulations Part 68.The specification includes physical construction, wiring, and signal semantics. Accordingly, registered jacks are primarily named by the letters RJ, followed by two digits that express the type. Additionally, letter suffixes indicate minor variations. For example, RJ11, RJ14, and RJ25 are the most commonly used interfaces for telephone connections for one-, two-, and three-line service, respectively. Although these standards are legal definitions in the United States, some interfaces are used world-wide. Specifically, for example, the IEEE 802 standards project has adopted RJ-type interfaces for ISDN (RJ48) and computer networking specifications (RJ45), such as Ethernet.The connectors used for registered jack installations are primarily the modular connector and the 50-pin miniature ribbon connector types. For example, RJ11 uses a six-position two-conductor connector (6P2C), RJ14 uses a six-position four-conductor (6P4C) modular jack, while RJ21 uses a 25-pair (50-pin) miniature ribbon connector.